[oC] (2) Cooling capacity correction coefficient Less than 1000 m 45 1.00 1000 m or more Less than 1500 m 42 0.85 1500 m or more Less than 2000 m 38 0.80 2000 m or more Less than 2500 m 35 0.75 2500 m or more Less than 3000 m 32 0.70 3.2.2 Location Install the product only in a location that may be subject to any of the conditions in "3.2.1 Environment".
as mounting an isolation transformer between the product and the power supply or keep the transient overvoltage of the power supply to 2500 V or less by using a varistor, etc.
10 40 30 Torque limit/Command value [%] Torque limit/Command value [%] Torque limit/Command value [%] Duty ratio [%] Continuous pushing time [minute] 25 or less 100 30 60 1.5 Torque limit/Command value [%] Duty ratio [%] Continuous pushing time [minute] 25 or less 100 30 60 1.5 LEY63 (Motor mounting position: Top/Parallel, In-line) 3500 Lead 2.86: LEY63L (Top/Parallel type only) 3000 2500
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Read the operation manual completely before operation, and keep this manual where it can be referred to as necessary. 14) In locations where strong impacts or vibrations occur 15)
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.
Flow Rate Characteristics Flow Rate Characteristics VBAT05A 2 1.6 0.1 ARJ 1.4 Outlet pressure (MPa) Outlet pressure (MPa) P1 = 1.0 MPa 1.2 P1 = 0.8 MPa Max. pulsation range (MPa) AR425 to 935 0.08 P1 = 0.75 MPa P1 = 0.7 MPa 1 P1 = 0.6 MPa P1 = 0.5 MPa P1 = 0.5 MPa 1 0.8 P1 = 0.4 MPa 0.06 ARX P1 = 0.3 MPa P1 = P2 0.6 P1 = P2 AMR 0.04 0.4 0.2 ARM 0.02 VBAT05A 0 500 1000 1500 2000 2500 3000
3930 165 220 264 344 422 563 739 880 1150 1370 1960 2180 3170 3520 5000 5500 20 25 32 40 50 63 80 100 Weights Basic weight: Mounting hole through (type B) Unit: g Bore size (mm) Standard stroke (mm) 10 199 278 407 514 838 1202 2229 3770 5 184 260 15 213 295 430 537 874 1242 2297 3860 20 227 312 453 560 910 1283 2364 3951 25 241 329 475 583 947 1324 2432 4041 30 255 346 498 606 983 1365 2500
3 2500 3000 A B How to Order (1) When adding n stations to ARM : Regulator n pcs. Bracket ass'y n pcs. (2) When regulators, end plate assembly and bracket assembly are assembled to make the manifold of n stations. Regulator n pcs. Bracket ass'y n pcs.
0.35 W) Nil VQZ2000/3000 Nil Standard A and B side of VQZ1000 single, double solenoid type A side of VQZ1000 3 position (0.9 W) B Note) High speed response type SY100-30-A Without lead wire: (with connector and 2 sockets only) 4 High pressure type (Metal seal type only) (0.9 W) K Note) 5 B side of VQZ1000 3 position Lead wire length Note) Option Nil 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500
Other pin materials available. consult factory PATENTED GAS ORIFICE VALVE PRESSURE RATINGS* SIZE CV FACTOR NUMBER LIQUID ORIFICE VALVE PRESSURE RATINGS* SIZE CV FACTOR NUMBER 3000 1/32 .022 EH21G7DCCM 3000 1/32 .022 EH21G7DCCM 2500 3/64 .041 EH21H7DCCMG 1500 3/64 .041 EH21H7DCCML 1350 1/16 .061 EH21J7DCCMG 850 1/16 .061 EH21J7DCCML 450 3/32 .084 EH21K7DCCMG 300 3/32 .084 EH21K7DCCML OPTIONS
Other pin materials available. consult factory PATENTED GAS ORIFICE VALVE PRESSURE RATINGS* SIZE CV FACTOR NUMBER LIQUID ORIFICE VALVE PRESSURE RATINGS* SIZE CV FACTOR NUMBER 3000 1/32 .022 EH21G7DCCM 3000 1/32 .022 EH21G7DCCM 2500 3/64 .041 EH21H7DCCMG 1500 3/64 .041 EH21H7DCCML 1350 1/16 .061 EH21J7DCCMG 850 1/16 .061 EH21J7DCCML 450 3/32 .084 EH21K7DCCMG 300 3/32 .084 EH21K7DCCML OPTIONS
Caution JIS Symbol CX 50, 63 6, 10 D3000 Bore siz Bore size Bore size 63 Type H ype H Type H 100 63 -X 90 2500 Bore siz Bore size e 10 Bore size 10 Theoretical thrust (N) Theoretical thrust (N) 80 20Type H ype H Type H 50 50 70 Type L ype L Type L 2000 60 Data Made to Order Specifications (For details, refer to page 8-31-1.) 1500 50 40 1000 30 Symbol Specifications 6 6 20 -XB6 Heat resistant
size Bore size 63 H H type L L type When mounting a floating bracket to a Series CY1B body, refer to P.67 for details, as this will be an order made product. 70 800 p32 32 700 60 600 50 500 p25 25 40 400 p20 20 30 p6 6 300 20 15 200 10 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Supply pressure (MPa) Supply pressure (MPa) 50, 63 3000 H H type 2500
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Handling Warning Thoroughly read the Operation Manual. 14) In locations where strong impacts or vibrations occur. 15) In locations where a massive force strong enough to deform the
Less than 3281 [1000] 113 [45] 1.00 Less than 4921 [1500] 108 [42] 0.85 Less than 6561 [2000] 100 [38] 0.80 Less than 8202 [2500] 95 [35] 0.75 Less than 9842 [3000] 90 [32] 0.70 14) In locations where strong impacts or vibrations occur. 15) In locations where a massive force strong enough to deform the product is applied or a weight from a heavy object is applied. 16) In locations where there
Lead wire length Nil 6 10 15 20 25 30 50 Positive common specifications : SX100-40-4S300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For single solenoid For double solenoid For 3 position type For 4 position type : SX100-40-4DElectric circuit diagram (With positive common and light/surge voltage suppressor) Negative common specifications : SX100-41-4SFor single solenoid For
Improved sealing Models and Specifications Note 1) Pneumatic cylinder Hydraulic cylinder Operating pressure Ambient temperature Applicable cylinder nominal thread size Allowable eccentricity U Max. tension and compression N 80 210 1100 2500 6000 11000 Applicable cylinder bore size (mm) 10 10, 16 20 25, 32 40 50, 63 Model M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 0.5 0.5 0.5
7.5 = 0.7 0.5 3000 9 10 0.1 0.3 500 2.5 1000 5 0 1,000 2,000 3,000 25 1500 7.5 Maximum speed Vmax (mm/s) 2000 10 32 1/4 1/4 2500 3000 12.5 15 30 6 10 1/4, 3/8 = 0.7 500 4 20 0.5 0.1 0.3 10 10 1/4, 3/8 32 1000 8 1/4, 3/8 3/8 3/8 3/8 1500 2000 2500 3000 12 16 20 24 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) 40 8 10 1/4, 3/8 500 6 40 = 0.7 30 40 3/8, 12 3/8, 12 3/8, 12 3/8, 12 3/8, 12
For other voltages of AC With light/surge voltage suppressor (Non-polar type) U : SY100-30-A Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 5 6 V
How to order L/M connector assembly Lead wire length Positive common specifications For single solenoid: SX100 40 4S B port N.C A port N.O Plug position Actuation Nil 300 mm Plug Plug 6 600 mm For double solenoid: For 3 position SX100 40 4D 10 15 20 25 30 50 1000 mm Number of solenoids 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Single Negative common specifications For single solenoid: SX100