SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-08-DO-00N"

Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 202

Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 35

CA2H100A-PS Do not disassemble the trunnion style. Seal kit includes !4, !5 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 40

Piston seal NBR Cushion valve seal NBR O-ring MBW100-PS Cylinder tube gasket NBR Do not disassemble the trunnion style. Seal kit includes !2, !3, !4 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.

CA2WH100A-PS Do not disassemble the trunnion style. Seal kit includes !0, !1 and !2. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63 or more: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 41

Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.

Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.

(Rubber, Metal sliding parts: Fluorine coated) Non-greased specification H/DL L/LL Single plug With check valve Single socket Metal part: Stainless steel 304, Rubber material: Fluororubber (Special FKM) Material KC With male thread sealant Seal Note 1) Do not use the S couplers with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.

Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Caution Maintenance Warning 1. Be sure to unlock the knob before adjusting the pressure and lock it after setting the pressure. Failure to follow this procedure can cause damage to the knob and the outlet pressure may fluctuate. Pull the pressure regulator knob to unlock.

Additionally, do not put the tube end in the liquid. This may cause the back pressure to be applied, resulting in poor performance. 3.Liquids cannot be collected by the air. 1076 A

. * If the step motor and servo motors do not meet your specifications, also consider the AC servo specification (Page 46). 38 Model Selection LEF Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Clean Room Specication For the LECPA, refer to page 40.

When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. Use special tool when crimping. (For the crimping tool, please consult with SMC.)

When the line is stopped, do not adjust or set the differenital pressure, as it could cause the differential adjustment valve to break. 3. When setting the pressure differential, if there is a fluctuation in the operating flow rate, set the pressure differential at the lower flow rate range.

Do not place a magnetic object near the pressure switch. Unintended operation may result. Caution Inlet pressure (MPa) Flow rate (L/min (ANR)) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.

Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.

Do not use the regulator with flow exceeding the Max. flow indicated in Flow Rate Characteristics as this can cause failure in pressure adjustment. Bleed port Component Parts Knob locking screw No.

(To set the pressure, do so in the direction of pressure increase.) 2. Set the outlet pressure to 85% or less of the inlet pressure. Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 387 to 391 for Precautions on every series. Inlet pressure (MPa) Mounting/Adjustment Warning 1.

Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Maintenance Caution Warning 1. Be sure to unlock the knob before adjusting the pressure and lock it after setting the pressure. Failure to follow this procedure can cause damage to the knob and the outlet pressure may fluctuate. Pull the pressure regulator knob to unlock.

Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Caution Maintenance Warning 1. Be sure to unlock the knob before adjusting the pressure and lock it after setting the pressure. Failure to follow this procedure can cause damage to the knob and the outlet pressure may fluctuate. Pull the pressure regulator knob to unlock.

/Single Unit), Solenoid Valve Option: G (SUS Body, NBR Seal, Class B), Suffix: Standard, Port Size: 01 (1/8), Thread Type: N (NPT), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector), Bracket: B (Bracket)