This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves. Available protocols include EtherNet/IP™. Enclosure: IP67 (Manifold Assembly); Operating temp. range: -10 to +50°C; Operating humidity range: 35% to 85% RH (No condensation); Standards: CE marking, RoHS compliant
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000 and S0700 valves. Available protocols include Profibus-DP, DeviceNet™, CC-Link, EtherCat and EtherNet/IP™.
IP67 enclosure (IP40 for SI unit compatible with ControlNet); Maximum 32 inputs/32 outputs; Connection of sensor with M8/M12 connectors possible; Available communication protocols include: DeviceNet, PROFIBUS DP, CC-Link, AS-i, CANopen and EtherNet/IP; Applicable to valves: VQC1000/2000/4000, S0700 and SV1000/2000/3000
Communication protocol: CC-Link, DeviceNet™, PROFIBUS DP®; Applicable valves: SJ2/3000, SY3/5/7/9000, SQ1/2000; RoHS compliant
The EX180 serial interface unit controls up to 32 solenoid outputs, and is compatible with series SJ2000/3000 valves. Available protocols include DeviceNet, and CC-Link.
Actuation control pressure isolated from process gas by two seals ; Body material: 316L SS secondary remelt ; High inlet pressure type: Standard Max. 2300 psig (15.9 MPa); HR Max. 3000 psig (20.7 MPa ; Flow capacity: Standard to 400 slpm ; Ni-Cr-Mo alloy internals standard ; 100 psig (0.69 MPa) outlet pressure achievable with 80 psig (0.55 MPa) control pressure or less
Actuation control pressure isolated from process gas by two seals ; Body material: 316L SS secondary remelt ; High inlet pressure type: Standard Max. 1700 psig (11.7 MPa); HR Max. 3000 psig (20.7 MPa ; Flow capacity: Standard to 800 slpm ; Ni-Cr-Mo alloy internals available for corrosion resistance ; 100 psig (0.69 MPa) outlet pressure achievable with 80 psig (0.55 MPa) control pressure or
Actuation control pressure isolated from process gas by two seals ; Body material: 316L SS secondary remelt ; High inlet pressure type: Standard Max. 2300 psig (15.9 MPa); HR: Max. 3000 psig (20.7MPa) ; Flow capacity: Standard to 400 slpm ; Ni-Cr-Mo alloy internals available for corrosion resistance ; 100 psig (0.69 MPa) outlet pressure achievable with 80 psig (0.55 MPa) control pressure
Actuation control pressure isolated from process gas by two seals ; Body material: 316L SS ; High inlet pressure type: Standard Max. 1700 psig (11.7 MPa); HR: Max. 3000 psig (20.7MPa) ; Flow capacity: Standard to 800 slpm; HF (Option) to 1000 slpm ; Ni-Cr-Mo alloy internals available for corrosion resistance ; 100 psig (0.69 MPa) outlet pressure achievable with 80 psig (0.55 MPa) control
Actuation control pressure isolated from process gas by two seals ; Body material: 316 SS ; High inlet pressure type: Standard Max. 2300 psig (15.9 MPa); HR (Option): Max. 3000 psig (20.7 MPa) ; Flow capacity: Standard to 400 slpm ; Ni-Cr-Mo alloy internals ; 100 psig (0.69 MPa) outlet pressure achievable with 80 psig (0.55 MPa) control pressure or less
This serial interface is compatible with series VQC1000/2000/4000 and SV1000/2000/3000 valves. Available protocols include DeviceNet, CC-Link, AS-i, Profibus-DP, and CANopen. Input modules can be added or removed at the point of use. Protection class: M12: IP67 and RJ45: IP20; EX250, EX260, EX500, EX600; Length: 1m, 2m, 3m, 5m, 10m
This serial interface is compatible with series VQC1000/2000/4000 and SV1000/2000/3000 valves. Available protocols include DeviceNet, CC-Link, AS-i, Profibus-DP, and CANopen. Input modules can be added or removed at the point of use. Protection class: M12: IP67 and RJ45: IP20; EX250, EX260, EX500, EX600; Length: 1m, 2m, 3m, 5m, 10m
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
Stepless control of air pressure proportional to an electrical signal Maximum supply pressure: 5.0 MPa Set pressure range: 0.01 to 3.0 MPa Maximum flow rate: 3000 L/min[ANR] Fluid: Air, N2, O2, Ar Wetted parts: Fluorine grease
Body sizes: 80 (400W), 100 (750W); Max. horizontal workload, kg: 75 (size 80); 240 (size 100); Max. vertical workload, kg: 40 (size 80); 70 (size 100); Max. speed, mm/s: 2160 (size 80); 4000 (size 100); Stroke range, mm: 300 to 3000 (see catalog for increments); Positioning repeatability, mm: ±0.08; Encoder resolution: 17-bit (S motor), 20-bit (V motors), 18 or 22-bit (T motors)
Body sizes: 80, 100; Max. horizontal workload, kg: 75 (size 80); 240 (size 100); Max. vertical workload, kg: 70 (size 80); 200 (size 100); Max. speed, mm/s: 5,000; Max. acceleration / deceleration, mm/s2: 50,000; Stroke range, mm: 300 to 3000 (see catalog for increments); Positioning repeatability, mm: ±0.08
.; Allowable rpm: 200 to 3000.; Operating pressure range: -100 kPa to 1.0 MPa.
Decentralized serial wiring; Tie rod base, 3000 series; IP67 protection; Number of outputs: 16; Maximum number of stations: 16(over 8 requires manifold spec. form)
Dedicated output serial wiring; Tie rod base, 3000 series; Series EX120; Number of outputs: 16; Maximum number of stations: 16(over 8 requires manifold spec. form)