A unique guide ring on the piston rod eliminates lateral motion of the poppet, increasing seal life and reducing particle formation.Orifice diameters: ø4, ø8, ø10, ø16, ø22, Flow characteristics: 0.35 to 8 Cv, Operating pressure: 0.3 to 0.5 MPa, Fluid temperature: 0 to 100° C, Ambient temperature: 0 to 60° C, Tubing O.D.: Metric size – 6, 10, 12, 19, 25;  Inch size – 1/4", 3/8", 1/2", 3/4

Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Flow Switch Type: Integrated Display, Rated Flow Range: 0.5 to 4 L/min, Return Unit Components: w/o Flow Adj.

Valve; w/Stop Valve, Return Port Size: 3/8, Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °C

Valve; w/Stop Valve, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Valve; Stop Valve: None, Return Port Size: 3/8, Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/o Lead Wire and M8 Connector, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Valve; Stop Valve: None, Return Port Size: 3/8, Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/o Lead Wire and M8 Connector, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: G, Flow Switch Type: Integrated Display, Rated Flow Range: 0.5 to 4 L/min, Return Unit Components: w/o Flow Adj.

Valve: None; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Valve; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Valve; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C

Orifice diameters: ø4, ø8, ø10, ø16, ø22; Flow characteristics: 0.35 to 8 Cv; Operating pressure: 0.3 to 0.5 MPa; Fluid temperature: 0 to 100° C; Ambient temperature: 0 to 60° C; Tubing O.D.: Metric size – 6, 10, 12, 19, 25; Inch size – 1/4", 3/8", 1/2", 3/4", 1"

SMC's pin clamp cylinder series C(L)KQG/P was designed with 4 body types for a broad range of installation conditions.  There are 55 types of guide pins available and an optional locking mechanism.  C(L)KQG/P series  has positioning and clamping at one time!  Precision adjustment of clamping height is possible by choosing the with-shim type.  Adjustment range: 0.5 to 3mm.

SMC's pin clamp cylinder series C(L)KQG/P was designed with 4 body types for a broad range of installation conditions.  There are 55 types of guide pins available and an optional locking mechanism.  C(L)KQG/P series  has positioning and clamping at one time!  Precision adjustment of clamping height is possible by choosing the with-shim type.  Adjustment range: 0.5 to 3mm.

Orifice diameters: ø4 ; Flow characteristics: 0.3 Cv ; Operating pressure: 0 to 0.5 MPa ; Fluid temperature: 0 to 100° C ; Ambient temperature: 0 to 60° C ; Tubing O.D.: Metric size (mm) – 3, 4, 6; Inch size – 1/8", 3/16", 1/4"

Power valve series, economy valve; Air operated & external pilot solenoid; Port sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, 2; Proof pressure: 1.5MPa; Ambient temperature: 0~50°C (air op: 60°C); Options: bracket, pressure gauge

Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 400 (4"), Stroke: 400 (4"), Body Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)