Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 20, 25 Bore, Stroke: 75mm, Body Option: CM (C+M), Auto Switch Groove: Z (ø20 to ø63, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

How to Order: LECP7 N 1 XB3 Dimensions Screw mountingLECP7***-*-XB3 DIN rail mountingLECP7**D-*-XB3 (2 ) (4 ) (1 ) (3 ) (1) Parallel I/O type (3) Option N NPN Nil Screw mounting P PNP D DIN rail mounting (2) I/O cable length (4) Actuator part number Nil Without cable Part number except cable specifications and actuator options Example : Enter LEFS16B-100B-R1 1 1.5m 3 3m for theLECP7**-LEFS16B

64 30 24 113 68 30 24 0.1 2505-003 45.9 3 8 2506-004 50.0 1 2 310 88.5 48 35 2507-006 105.6 3 4 514 97.5 60 41 2508-010 129.6 1 57 54 22 19 2510-002 17.2 1 4 55 56 22 19 2511-003 17.2 3 8 0.05 0.02 0.01 0.005 0.002 Construction/Parts/Dimensions 50 100 200 500 1000 2000 5000 10 20 Port size Air flow (l/min (ANR)) Case (ZDC) Noise Level (Initial conditions) Hexagonal flats D (2507-006: Width

Electrical entry Rated voltage G Grommet 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz C Conduit D DIN terminal 3 110 VAC 50/60 Hz T Conduit terminal 4 220 VAC 50/60 Hz 7 240 VAC 50/60 Hz Refer to the table (1) given below for availability. 8 48 VAC 50/60 Hz 9 Other (Only AC) Table (1) Rated VoltageElectrical Entry-Electrical Option Caution Insulation type Electrical entry Electrical option 1 (100

In accordance with the dissolution method, carry out the quantitative study of fluorine ions. 0.4 0.2 0.0 Metal ion elution (ng/cm2) Note 4) 20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Kind Al Fe Ni Na Ca Operating temperature (C) Amount of elution 0.1 or less 0.1 or less 0.1 or less 0.1 0.1 or less Clean the inside of fluoropolymer tube with ultrapure water.

function Wiring (output) Type Electrical entry 0.5 (Nil) 3 (L) 5 (Z) DC AC 3-wire (NPN) 3-wire (PNP) 2-wire M9N M9P M9B A90 A93 5 V, 12 V Solid state switch Relay, PLC 24 V Grommet Yes 12 V 5 V, 12 V 12 V 100 V or less 100 V IC circuit no Yes Relay, PLC 24 V 2-wire Reed switch Grommet 161

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: R (NBR Seal, Nitrile Rubber), Stroke: 100 mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: Ø80 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: V (FKM Seal, Fluororubber), Stroke: 100 mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: V (FKM Seal, Fluororubber), Stroke: 100 mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Stations: Stations, Wiring: D-sub Connector, Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Complex Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function, Leadwire: without Leadwire, Unit Options: Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type, 1st Nominal

Stations: Stations, Wiring: D-sub Connector, Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Individual Port Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function, Leadwire: 2m Switch/Sensor Only, Unit Options: with Unit Options J & K, 1st Nominal Nozzle Size: ø1.2, 1st

Stations: Stations, Wiring: D-sub Connector, Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Individual Port Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function, Leadwire: 2m Switch/Sensor Only, Unit Options: with Unit Options J, K, & W, 1st Nominal Nozzle Size: ø1.2

Stations: Stations, Wiring: D-sub Connector, Manifold Options: with Manifold Options B & D, Exhaust: High Noise Reduction Silencer Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function, Leadwire: 2m Switch/Sensor Only, Unit Options: without Option, 1st Nominal Nozzle Size: ø0.7, 1st Selection Supply

Stations: Stations, Wiring: D-sub Connector, Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Complex Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function, Leadwire: without Leadwire, Unit Options: Vacuum Break Flow Adjusting Needle, Round Lock Nut, 1st Nominal Nozzle

Stations: Stations, Wiring: D-sub Connector, Manifold Options: with Manifold Options B & D, Exhaust: Complex Exhaust, Pressure Switch for Vacuum/Pressure Sensor: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function, Leadwire: 2m Switch/Sensor Only, Unit Options: with Unit Options J & K, 1st Nominal Nozzle Size: ø1.0, 1st Selection Supply Valve and Release

(mm): 15, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 100, Applicable Tube Size: Metric Size, Specification: Standard Product, Maximum operating pressure(MPa): 2.3, Operating Temperature(°C): Air, Inert Gas: -20 to 200 / Water: 0 to 100 (Do Not Freeze)

(mm): 20, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 100, Applicable Tube Size: Metric Size, Specification: Standard Product, Maximum operating pressure(MPa): 1.7, Operating Temperature(°C): Air, Inert Gas: -20 to 200 / Water: 0 to 100 (Do Not Freeze)

(mm): 35, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 100, Applicable Tube Size: Metric Size, Specification: Standard Product, Maximum operating pressure(MPa): 1.5, Operating Temperature(°C): Air, Inert Gas: -20 to 200 / Water: 0 to 100 (Do Not Freeze)

(mm): 60, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 100, Applicable Tube Size: Metric Size, Specification: Standard Product, Maximum operating pressure(MPa): 1, Operating Temperature(°C): Air, Inert Gas: -20 to 200 / Water: 0 to 100 (Do Not Freeze)

Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Black] Black (opaque), Outer Diameter Class: ~10, Compatible Fluid: Water / Air, Outer Diameter D(Ø): 10, Inner Diameter Class: ~8, Inner Diameter d(Ø): 8, Material: Fluororesin: [Standard Fluororesin] FEP (Tetrafluoroethylene hexafluoride propylene copolymer resin), Minimum Bending Radius(mm): 100, Operating Environment