(mm) Voltage(V) 10% 15 2200 300 Single100 55/65 37 5700 350 X 2 3-phase200 132/170 X 2 1.44/1.4 11/2B union 55 22 3300 400 3-phase200 90/130 0.4/0.45 B union 36 Single200 38/46 3-phase200 50/60 Cooling fan (50/60Hz) Power consumption (W) Current (A) 0.46/0.52 0.23/0.26 Rp(PS) Socket 18 0.8/0.9 0.4/0.35 1B union 24 11 2 Port size Weight (kg) 3 4 Compact size and light weight Note 1) Based
Model: LVH40 (Body Class 4, N.C.), Lever Operation: Non-locking, Self-reset, Port Size: 04 (1/2), Pilot Port Thread: N (NPT), Material: A (Body: SUS, Actuator Section: PP, Diaphragm: PTFE)
Function: 2 (2 Position Double), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 04 (Sub-plate 1/2)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 5 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: YO [DIN Terminal (EN175301-803) w/o Connector], Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: F (G), Actuation Type: A (N.C., Normally
Model: LVH40 (Body Class 4, N.C.), Lever Operation: L (Locking), Port Size: 04 (1/2), Pilot Port Thread: N (NPT), Material: A (Body: SUS, Actuator Section: PP, Diaphragm: PTFE)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only)
Stations: 04 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: EB (EtherNet/IPâ„¢ IO-Link), End Plate: 3 [Power Supply w/7/8" Connector (Max. Supplied Current 8 A)], SI Unit Common: N (-COM), I/O Unit Stations: None, Option 1: None, DIN Rail Length: None, Option 2: S (Built-in Silencer, Direct Exhaust)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: F (G)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: S (5VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2)
Size: 3 (30), Valve Type: 1 (Normally Closed), Body Material: A (Aluminum), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: G (Grommet)
Control Method: E (Meter-out, Gray), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread Type: G (G), Port Size: 01 (1/8)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread Type: G (G), Port Size: 01 (1/8)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
, Bracket: None, Calibration Certificate: A (w/Calibration Certificate)
Certificate: A (w/Calibration Certificate)
Certificate: A (w/Calibration Certificate)