Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple 1% or less) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 50 M or more (500 VDC measured via megohmmeter) (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Extension cable (Option) 5 m, 10 m, 15 m, 20
CH kPa 4 3 2 1 SW t e AV y D-IN RUN UP SET P-ON AU DOWN STOP READ r u AF i AR o Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com t y u i o IR !
Applicable blank plate assenbly SY100-77-1A VZ P R 20 stations 20 R port VS A port M5 X 0.8 P port M3 X 0.5 M5 X 0.8 M5 X 0.8 Note 1) SY114 (A) and SY124 (A) cannot be mounted on the same manifold.
Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 37 CX 5H9 depth 5 +0.030 0 5H9 depth 5 +0.030 0 92 DNN-4.2 26 11.5 NN-8 -X 208.5 H 2-M5 x 0.8 thread depth 12 Data 5.5 NN-M5 x 0.8 NN 2 ( 1) x H 13 G Section AA A M 12 Operating port 2-M5 x 0.8 0.5 25 (Table length) N 2 ( 1): The number of pitches 27 7 12 J 3 Z Max. 9.5 ZZ
(mm) Model KQGL04-00 KQGL06-00 KQGL08-00 KQGL10-00 KQGL12-00 4 6 8 10 12 KQGH04-M5 KQGH04-01S KQGH06-M5 KQGH06-01S KQGH06-02S KQGH08-01S KQGH08-02S KQGH08-03S KQGH10-02S KQGH10-03S KQGH12-03S KQGH12-04S M5 4 R1/8 M5 6 R1/8 R1/4 Male Branch Tee Male Branch Tee R1/8 8 R1/4 Applicable tubing O.D.
0 0.043 43 8 50 16 40 13 22 5 2 8 12 1.0 M5 1.1-10
x 0.8 14.9 20.9 6.6 12.6 11.6 2.1 4 MHZ2-20D 9 5 M5 x 0.8 M5 x 0.8 M5 x 0.8 16.3 26.3 7.2 17.2 14 2.1 4 MHZ2-25D 6 12 M5 x 0.8 M5 x 0.8 M5 x 0.8 19.3 33.3 8.8 22.8 19 3.5 4 Note) Through-hole mounting is not possible for 10. 925 Standard Type / Series MHZ2 Finger Option 1122Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors
Easy and simple wiring Connector type 16-6-7 2 Series ZSE2/ISE2 How to Order Operating pressure range/ Setting pressure range Piping specifications Single mounting R 1/8, M5 x 0.8 01 T1 Single mounting NPTF 1/8, M5 x 0.8 Nil L 0 to 1 MPa 0 to 100 kPa Note) M5 x 0.8 (female) thread.
Tightening of fittings When connecting fittings, etc., to valves, tighten as indicated below. 1) M5 type 1. When using SMC fittings, follow the guidelines below. M5: After tightening by hand, tighten an additional 1/6 turn with a tightening tool. However, if miniature fittings are used, tighten an additional 1/4 turn with a tightening tool after tightening by hand.
(Select wiring bottom entry when the semi-standard Y is chosen simultaneously.)
Y (EX245-DX1)(EX245-DY1) Y 2 PCA-1557785 Y (2M12 M12) A A A . 10-2 Y (PCA-1557785) 64 No.EX-OMU0020CN PCA-1557798 Y (2M8 M12) A . 10-3 Y (PCA-1557798) 65 No.EX-OMU0020CN 10.3.
A E1 L R1 NZ NX MM +0.2 +0.1 +0.2 +0.1 +0.3 +0.1 36 Y-020B Y-032B Y-040B 9 46 16 20 25 5 14 18 M8 X 1.25 CDP-1 20 9 C9 type for pivot 38 9 48 18 20 25 5 14 18 M10 X 1.25 CDP-1 25,32 9 C9 type for pivot 55 12 68 22 24 49.7 13 25 38 M14 X 1.5 3 X 18l CDP-3 40 16 Clevis pins and snap rings (cotter pins for bore size 40) are attached.
Center of gravity *MHM-25D-X7400A-DTP Z TCP Y X Flange mounting surface MHM-25D-X7400A-DTP MHM-25D-X7400A-HC10DT MHM-25D-X7400A-HC10 X Y Z X Y Z X Y Z Center of gravity(mm) 2.4 0.0 42.6 1.0 -0.4 57.1 1.0 -0.4 57.9 X Y Z X Y Z X Y Z Tool Center Point(TCP) 0 0 114 0 0 138 0 0 140 17 - 4.
M5 x 0.8 Prepared hole diameter 4.2 20 W 0.50.05 D B Vacuum port M5 x 0.8 Piping port 2 x M5 x 0.8 33 32 10 J depth 1.5 3 5.5 5 12 9.5 +0.030 0 4 Section AA B D Mounting base side +0.030 0 depth 1.5 3 Q QL 11-/22-MXP12-25 Without magnet and switch rail 2 x M2 x 0.4 depth 3 8 5.7 3.5 L 20 20 6 x M4 x 0.7 depth 4.5 2 x M3 x 0.5 depth 3.5 (mm) G H J K L M Q QL S V W Z Model 11-/22-MXP12-15
20 Width across flats 8 Width across flats 3 A 4-M5 x 0.8 depth 7 (Plug: M-5P) 2-M5 x 0.8 Piping port H 17 M6 x 1 10.5 26.7 11 5 5.5 34 35 8.5 4-M6 x 1 +0.030 0 depth 4 4H9 depth 4 4H9 Prepared hole diameter 5.1 A 6.5 19 320.05 +0.030 0 30 0.50.05 W B D 2-M5 x 0.8 Piping port M5 x 0.8 Vacuum suction port 47 46 13 10.5 depth 2 4H9 J 8 +0.030 0 +0.030 0 depth 2 4H9 16.5 14.5 Section AA 5 Mounting
0 u y 32 to 50 With auto switch (built-in magnet) !6 q e r t !5 i o !1 !3 !2 !7 w !4 !0 u y Description No.
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
Z directions for 2hrs. each (deenergized) 980m/s (100G) in X, Y, Z directions 3 times each (deenergized) In a temperature range of 0 to 50C, 2% F.S. or less of pressure measured at 25C Vibration resistance Impact resistance Temperature characteristics 01: R1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc1/8 C4: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads 5 wire
Z directions for 2hrs. each (deenergized) Vibration resistance Impact resistance 980m/sX (100G) in X, Y, Z directions 3 times each (deenergized) In a temperature range of 0 to 50C, 2% F.S. or less of pressure measured at 25C Temperature characteristics 01: R1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc1/8 Port size C4: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads
258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF Connector type Grommet type Heat-resistant vinyl electric wire 1.55 0.31 mm2 4-wire Oil-resistant vinyl cabtire code -21, -23: 3.5 0.14 mm2 4 cores -22, -24: 3.5 0.15 mm2 5 cores Lead wire Data Weight 40 g (including 0.6 m-long lead wire) R 1/8, M5 x 0.8, NPTF 1/8, M5 x 0.8 Port size R 1/8, M5 x 0.8 NPTF 1/8, M5 x 0.8 ZX ejector mounted