How to Order AD402 04 A D Semi-standard symbol: When plural options are required, indicate them in alphanumeric order.
Option/Semi-standard symbol : When more than one specification is inqures, indicate in alphanumeric order. 3 4 5 6 2 1 Symbol Description 0 0.01 to 0.2MPa 1 0.01 to 0.4MPa Set pressure range 2 0.01 to 0.8MPa + 0 Bottom exhaust 1 Front exhaust Exhaust direction 2 Back exhaust + Nil Rc N NPT Thread type F G + 02 1/4 03 3/8 Port size 04 1/2 + Nil Without mounting accessories B With bracket
I NA D J A F N2 N1 MM S + Stroke F H ZZ + Stroke (mm) P Bore size (mm) MM A NN D F G1 G2 S ZZ I H J N1 N2 NA TN TF 10 15 M12 x 1 4 M5 x 0.8 8 15 6 M4 x 0.7 65 101 18.5 28 16 11 20 16 16 15 M14 x 1 5 M5 x 0.8 10 15 6 M5 x 0.8 74 114 22 30 22 12 21 19.5 20 18 M20 x 1.5 8 Rc 1/8 13 NPT 1/8 25 G 1/8 8.5 M8 x 1.25 97.5 151 31.5 40.5 28.5 20.5 33 29 25 M10 x 1.25 18 M26 x 1.5 10 Rc 1/8 13
Specifications 2-1 How to Order Metric size (Release button: Light gray) Metric size ZFB 0 Inch size ZFB 1 Body type Symbol Filtration area (mm2) 10 1037 20 1584 30 1980 40 3016 Inch size (Release button: Orange) Applicable tubing size Metric size Symbol Applicable tubing Applicable model ZFB10 ZFB20 ZFB30 04 4 06 6 08 8 10 10 Inch size Symbol Applicable tubing Applicable model ZFB10 ZFB20
D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL D-A7/A80 D-A73C/A80C D-A7H/A80H D-F7/J79 D-F7V D-J79C D-F7WV D-F7BAVL D-F7W D-J79W D-F7BAL D-F7NTL D-F79F No. of auto switch mounted D-A79W 15 15 15 20 1 pc. 15 15 20 20 2 pcs.
18 D No Option Ports T Metering (1/32 1/8 orif.)
2.1 0.34 .39 0.35 0.35 0.27 0.32 0.24 0.55 0.59 0.59 0.59 0.47 0.39 0.51 2.3 2.4 2.3 2.4 2.2 2.2 2.3 0.27 0.32 0.27 0.36 0.32 0.27 0.31 0.59 0.62 0.54 0.66 0.56 0.54 0.59 1/8 1/4 1/8 1/4 1/4 1/8 Body ported For internal pilot VZ52 1/8 1/8 1/8 1/8 C6 Base mounted For internal pilot VZ54 VV3Z5-41-1 1/4 1/4 C8 Body ported For external pilot VV3Z5-21R-1 VZ52R 2.2 0.34 0.55 2.4 0.32 0.62 1/4
Fittings & Tubing Air Cylinders Rotary Actuators BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch a e White (PBT) b Switch holder d Auto switch mounting screw c Auto switch mounting band Band
fitting Applicable series Type of actuation SY3000 2 position single (A) 4 (B) 2 1 SY5000 5 (EA) 3 (EB) 1 (P) 2 position double (A) 4 (B) 2 2 SY7000 5 (EA) 3 (EB) 1 (P) 3 position closed center (A) 4 (B) 2 3 Manual override 5 (EA) 3 (EB) 1 (P) 3 position exhaust center Nil: Non-locking push type E: Knob locking type D: Slotted locking type (A) 4 (B) 2 4 5 (EA) 3 (EB) 1 (P) 3 position pressure
Rc 1/8 pilot port 2-Mounting hole Port size Rc (EXH port) Port size 2-Rc (IN, OUT port) IN, OUT EXH Port size Rc A Model Mounting hole C D E F G H K L B J 3 8 1 2 3 4 VPA3145 71 3 4 85 14 52 55 93 32 87.4 36 71 80 8.5 3 4 VPA3165 82.6 1 4 1 1 110 17 68 75 118 45 113 36 71 95 8.5 1 4 1 1 1 1 4 VPA3185 118 1 2 132 14 80 95 140 52 140 41 81 105 13 2 2 5-5-26
3 Port Air Operated Valve VPA3145/3165/3185 Series How to Order 04 4 5 1 VPA3 Thread type VPA Air operated valve Nil Rc G NPT NPTF F N T Port size (IN, OUT port) Number of pilot 1 Single Symbol Port size Rc size VPA3145 VPA3165 VPA3185 Body size 03 04 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 06 10 12 14 20 8 1 2 1 Valve option Nil For ordinary pressure For vacuum and low pressure
Note 1) l (Drill through) Cotter pin d D m Dd9 L H B C 3 x 18l 4 x 25l 4 x 35l M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 36 51 72 4 4.5 5 3 4 4 44 60 82 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 -0.040 -0.076 -0.050 -0.093 -0.065 -0.117 Note 1) A cotter
L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max. Model Port size Model Port size 120 150 AS800 AS900 1 1 , 2 74 93 204 262 192 250 80 94 AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 15-9-33
Minimum Stroke for Auto Switch Mounting [mm] Auto switch model Number of auto switches Bore size 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) D-M9V 1 5 2 5 D-M9 1 51 5 2 101 10 D-M9W 1 52 2 102 10 D-M9WV D-M9AV 1 52 2 10 D-M9A 1 52 2 102 1 Confirm that it is possible to secure the min. bending radius of 10 mm of the
D D Note) Be sure to use a flat washer for the A type mounting. b) B type mounting (when using the cylinder tube threads) E t E t Compatible mounting bolt dimensions Model A type mounting B type mounting C (mm) D: Bolt length (mm) Mounting bolt size E (mm) Mounting bolt size MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D M4 x 0.7 35 + Stroke
CE1 CE2 Mounting Style and Accessory ML2B L: Foot style Note F: Rod side flange style G: Head side flange style C: Single clevis style D: Double clevis style Mounting B: Basic style C J G5-S (2 pcs.) (1 pc.) (1 pc.) (1) (1 pc.
CE1 CE2 Mounting Style and Accessory ML2B L: Foot style Note F: Rod side flange style G: Head side flange style C: Single clevis style D: Double clevis style Mounting B: Basic style C J G5-S (1) (1 pc.) (1 pc.) (2 pcs.) (1 pc.
Flat ribbon cable (10 pins) Symbol Stations 02 09 Symbol Stations 02 04 2 stations 9 stations 2 stations 4 stations Non-polar type, with plug (24 VDC) SJ3A6-5CU-DP (4 sets) SUP/EXH block (D side mounting) J: Flat ribbon cable (PC wiring) S6B: EX510 serial transmission Symbol Stations 02 08 Symbol Stations 02 08 2 stations 8 stations 2 stations 8 stations 1 3 2 D side U side Stations G: Flat
Contact input/output (D-sub 25 pin) and Serial RS-485 (D-sub 9 pin) (Refer to pages 92 and 93.) 170 UL, CE marking, SEMI (S2-0703, S8-0701, F47-0200), SEMATECH (S2-93, S8-95) Note 1) It should have no condensation.