Confirmation of allowable load weight by application Vertical downward: Press Horizontal: Chucking Vertical upward: Lifter l l m m F m F Maximum speed (mm/s) Load center of gravity position l (mm) Maximum speed (mm/s) to 300 to 500 to 700 to 300 to 500 to 100 to 200 to 300 Graph Graph Graph Graph Graph Graph Graph Graph l: The dimension for the load center of gravity position is the dimemsion
110 { } 5 150 194 125 G1/2 Electric conduit 35 At accessory E: 195 At accessory F: 275 { } 4 x M8 x 1.25 depth12 (Female thread for rear mounting) With optional resin cable clamp Applicable cable O.
TQ1230001-OM107 ModelZPG16J-7A-X2 ModelZPG(B25,B30)J-7A-X2 (Suction cup formMultistage bellows type 2.5-Stage) (Suction cup formMultistage bellows type 3.5-Stage) Dimensions Model A B D E F G H ZPGB25J-7A-X2 25 26 27 10.2 32.5 48 52.5 ZPGB30J-7A-X2 30 33 32 13.8 38 54.5 59 Note1) D and (st) indicate the reference value during gripping at vacuum pressure: -85[kPa]. -13No.
G H J K L M N P Q IDF1E Rc3/8 69 101 270 32 21 330 IDF3E Rc3/8 473 67 304 33 73 31 36 154 21 330 226 410 413 125 240 15 38 150 IDF2E Rc3/8 51 232 138 24 327 IDF4E / IDF6E / IDF8E / IDF11E ( 10 :0.8m) [ AC100V ] [ AC200V ] (:1.9m) [ AC200V ] (17) mm A B C D E F G H J K L M N P Q IDF4E Rc1/2 453 13 498 568 31 42 283 355 80 230 32 15 284 15 240 80 275 IDF6E Rc3/4 455 270 485 IDF8E Rc3/4
C D E F G J K 2(A) 1(P) 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHK-B2A 49 17 1 30 25 21.5 31 VHK-B2A 49 17 1 30 25 21.5 31 VHKlR-01S-01S 13 13 17 19 22 VHKlR-02S-02S 17 VHKlR-03S-03S 19 3.6-5 VHKlR-04S-04S 22
Adapter Material: Brass, Standard, Vacuum Inlet Direction: T (Vertical), Pad Diameter: ø50, Pad Styles: B (Bellows), Material: F (Fluoro Rubber), Vacuum Entry: N01 (Female Thread, NPT 1/8)
Adapter Material: Brass, Standard, Vacuum Inlet Direction: T (Vertical), Pad Diameter: ø40, Pad Styles: B (Bellows), Material: F (Fluoro Rubber), Vacuum Entry: N01 (Female Thread, NPT 1/8)
Adapter Material: Brass, Standard, Vacuum Inlet Direction: T (Vertical), Pad Diameter: ø10, Pad Styles: B (Bellows), Material: F (Fluoro Rubber), Vacuum Entry: N01 (Female Thread, NPT 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)
Model: F (Female Connector), Applicable Tube O.D.: 09 (5/16"), Port Size/Applicable Tube: N01 (1/8" Thread)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)