Key lock setting 0 0 to 3 Control mode setting , AT sensitivity setting 2.0 0.0 to 999.9 PB (heating) range setting 7.0 0.1 to 200.0% I constant setting 250 0 to 3600 D constant setting 0 0 to 3600 Heating for the proportional frequency setting 2 1 to 120 ARW setting 100.0 0.0 to 100.0 PB (cooling) range setting 0.50 0.0 to 10.00 Cooling for the proportional frequency setting 2 1 to 120 01
11 70 h 2)-700.00mm GW [OUT Data]Address.6 Address.9 Address.7 Address.6 01h 00h 15bit 8bit 7bit 0bit (H) 00 01 11 70 h (H) Address.9 Address.8 70h 11h 15bit 8bit 7bit 0bit (L) 00 01 11 70 h (L) 0.01mm 2 -700.00mm -7016 FFFEEE90h PLC FF FE EE 90 h Address.7 Address.6 FEh FFh 15bit 8bit 7bit 0bit (H) FF FE EE 90 h (H) Address.9 Address.8 90h EEh 15bit 8bit 7bit 0bit (L) FF FE EE 90
IR2000 : G43-2-01 G43-P2-N01-X30 IR2010 : G43-4-01 G43-P4-N01-X30 IR2020 : G43-10-01 G43-P10-N01-X30 Port size 02 : 1/4 Note4) Set pressure Thread type NIL:Rc N:NPT 0: 0.005~0.2MPa 1: 0.01~0.4MPa 2: 0.01~0.8MPa F:G (Note 3) The pressure gauge is not attached and becomes bundled shipment. (Note 4) One type only. 4. Marking on product Product name plate MAX.SUP.PRESS. MAX.SUP.PRESS.
IR3000 : G43-2-01 G43-P2-N01-X30 IR3010 : G43-4-01 G43-P4-N01-X30 IR3020 : G43-10-01 G43-P10-N01-X30 Set pressure Thread type NIL:Rc F:G 0: 0.01~0.2MPa 1: 0.01~0.4MPa 2: 0.01~0.8MPa N:NPT (Note 3) The pressure gauge is not attached and becomes bundled shipment. 4. Marking on product Product name plate MAX.SUP.PRESS. MAX.SUP.PRESS. MAX.SUP.PRESS.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WEN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (16 points) 2 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#B (8 points) 0 1 EX600-DY
Content 0 to 5 A channel number of 0 to 63 is displayed. 6 Input/Output Type: 00 = Reserved, 01 = Input, 10 = Output 7 -68No.EX-OMN0028-B Diagnostic type Bit No.
. (3) Common supply pressure (PV) connecting port size (4) Common vacuum burst pressure (PD) port Note 2) 01 Rc1/8 01N NPT1/8 01F G1/8 M5 M50.8 NIL Without PD port (PV = PD) M5 M50.8 PVPD Note 2)Refer to model indication for single unit (4) for the combinations of supply valve and release valve selectable. 14 - Doc. no.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
(at 500 VDC) between terminals and case Standards CE/UKCA marked, UL (CSA) -21No.PF-OMJ0016-J Specifications of piping port Model 01 02 N01 N02 F01 F02 C4 C6 C8 N7 4 8 6 1/4 (5/32") (5/16") Thread type (Port size) Rc Rc NPT NPT G G OneOneOneOne1/8 1/4 1/8 1/4 1/8 1/4 touch fitting touch fitting touch fitting touch fitting Straight without flow adjustment valve 95 g 125 g 55 g Bottom entry
Description Part number Remarks Panel mount adapter ZS-39-B Panel mount adapter + Front protective cover ZS-39-D Front protective cover ZS-39-01 Lead wire with connector + connector cover ZS-39-5G 5 cores, 2 m R1/8 conversion adapter ZS-39-N1 NPT1/8 conversion adapter ZS-39-N2 DIN rail mounting adapter ZS-39-R : Made to Order -10No.PS-OMM0005-J Summary of Product parts Names of individual
Alarm Code.01 to 20, 22, 24, 25: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. Alarm Code.21, 28: Eliminate the error cause, and power cycle the main breaker to enable error recovery to take effect.
Alarm Code.01 to 08, 10 to 19, 22, 24, 29, 30: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. Alarm Code.09: Eliminate the error cause.
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
1 Metering Valve with Silencer Series ASN2 Superior sound reducing performance Over 20 dB at max. flow rate Cylinder speed easily set Shape of needle is the same as that of speed controller Retainer prevents accidental loss of needle Model Model Port size Effective area (mm 2) Weight (g) ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 M5 x 0.8 10-32 UNF 1.8 1.8 3.6 6.5 16.6 24.5 5 5 17
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Order Made 2 With IN-OUT Flange 1 With Pressure Differential Gauge (GD40-2-01) A pressure differential gauge can be installed in the body to check the life of the filter element. It allows for easier piping and compact size. For easier flange piping.
How to Calculate the Flow Rate For obtaining the flow rate, refer to page 4-1-6. 4-16-1 2 Series VS3115/3110 How to Order VS311 D L 5 01 5 Thread type Accessory (Option) Nil Rc Mounting With indicator light L P With manual override N NPT T NPTF E Nil Without bracket Port size Piping Electrical entry B With bracket G 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Without sub-plate Rc 01 02 02 03 00 Body ported
This is a legacy product, and replaced byG36-10-01, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .17213 lb, ModelPressure range (1)Indication unitConnection threadNote MPapsiG36-10-01-X2G36-10-01-X20 to 1.0?MPaR 1 8Plated stem (Ni)
ISA11-4L-01BG ZSE2 ISE2 ISA15-1-01G ZSP ISl ZSM Accessories (Optional) PFl Bracket ISA-1-A Gauge G33-3-01 DIN rail ISA-2-1 to 7 IFl Gauge/G33-3-01 Bracket /ISA-1-A DIN rail/ISA-2-1 to 7 Material: SPC (Nickel plated) Material: Aluminum 10 hex. 100 110 q w e r t L 90 10 25 5 4-4.5 7.5 30 R1/8 34 42 28 4.5 35 27 9 16.5 13 5.6 L Applicable model Part No. 105 140 175 210 245 280 315 Description
G46-10-01) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter N. Please contact SMC concerning the supply of NPT pressure gauges. Relieving type is provided as standard for AU100.