SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS2-01-031-02"

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 01 (1/8), Applicable Tubing O.D: 06 (ø6)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: N (NPT), Port Size: 01 (1/8), Applicable Tubing O.D: 07 (ø1/4"), Sealant: S (w/Sealant)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 01 (1/8), Applicable Tubing O.D: 08 (ø8), Sealant: S (w/Sealant)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 01 (1/8), Applicable Tubing O.D: 06 (ø6), Sealant: S (w/Sealant)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: N (NPT), Port Size: 01 (1/8), Applicable Tubing O.D: 09 (ø5/16"), Sealant: S (w/Sealant)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: N (NPT), Port Size: 01 (1/8), Applicable Tubing O.D: 09 (ø5/16"), Sealant: S (w/Sealant)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 1 (Meter-in), 1: 1, Thread Type: N (NPT), Port Size: 01 (1/8), Applicable Tubing O.D: 09 (ø5/16")

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D: 08 (ø8)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: N (NPT), Port Size: 01 (1/8), Applicable Tubing O.D: 09 (ø5/16")

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

G <& C D, T G, C S L, Z S L, Z 8 8 8 8 8 8 8 8 8 8 8 8 T 9 '01 !" % % :"; % %%& !" % % :; S Note) 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) How to Order Manifold Arrangement of solenoid 9= Write both the base part number and the solenoid valve to be mounted or blanking plate part number. !"

Power Connector Molex lnc. part numbr 39-01-2180 (receptacle), 39-00-0039 (pins).

D I N 'E Terminal 'T Conduit Temlnal 'H 24' Lead hing 01 %'(AXSrd.) t M5 NOM 10-32 ilanual Overrida _Recessed, Nonlocking (Std.)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 01 (1/8), Applicable Tubing O.D: 08 (ø8)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: N (NPT), Port Size: 01 (1/8), Applicable Tubing O.D: 07 (ø1/4")

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D: 06 (ø6)

Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 02 (1/4), Applicable Tubing O.D: 10 (ø10), Sealant: S (w/Sealant)

B ASS 00 3 AQ ASV Body size Accessory 1 8 Nil None With bracket 1 3 5 6 AK 8 3 B 3 4 1 Port size ASS Applicable series Port size 01 02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Nil N F Rc

Applicable bore size (mm) d H1 B1 C D NT-02 20 M8 x 1.25 5 13 (15) 12.5 NT-03 25, 32 M10 x 1.25 6 17 (19.6) 16.5 NT-G04 40 M14 x 1.5 8 19 (21.9) 18 NT-05 50, 63 M18 x 1.5 11 27 (31.2) 26 NT-08 80 M22 x 1.5 13 32 (37.0) 31 NT-10 100 M26 x 1.5 16 41 (47.3) 39 D-X Technical Data 309 Air Cylinder: Standard Type Double Acting, Double Rod CG1W Series 20, 25, 32, 40, 50, 63, 80, 100 How to Order

ML1C 25 Bore size (mm) Auto switch model D20 20 25 32 40 32 20 D-B5/B64 D-G5/K5 BA-01 BA-02 BA-32 BA-04 25 20 -X 10 D-C7/C80 D-H7 BMA2-020 BMA2-025 BMA2-032 BMA2-040 20Mounting screws set made of stainless steel The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.