For details, please refer to page 14. DeviceNet DeviceNet CC-Link CC-Link PROFIBUS-DP PROFIBUS-DP Remote I/O AS-i CANopen Nil +COM. COM.
Enabling/Disabling of AL27: CH2 electric conductivity increase alarm function (1) (2) (3) (4) Electric conductivity and alarm (AL27) setting HRL Series 5.4 Description of Screen 5-41 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions Table 5.4-14 Settings of electric conductivity (AL27) No.
H L 7 26 (Max. 28) 12 7 IN OUT 12 Panel cutout dimensions 28 ARM10F1-06GPC 08GPC 4 x R1 or less 28 to 28.5 IN OUT 38 58 34 23 20 Plate thickness: Max. 2.1 30 15 6 OPEN 34 14 0.6 0.4 0.2 0.8 1 0 MPa 62 SMC P K U C S O H L 7 26 (Max. 28) 7 IN OUT 12 744 Regulator/Single Unit Type Options Pressure Gauge One-touch Fittings for Regulator VVQ1000-50A C4 Part no.
B Model A B C D E F G CXS6 9 2.1 3.25 6.5 7 1.2 x 12 10 CXS10 9 2.1 5 10 7 2.5 x 14 10 G CXS15 12 2.1 6 12 7 3 x 16 13 CXS20 15 3.1 7 14 10 4 x 20 16 CXS25 20 3.1 7 14 10 5 x 22 21 CXS32 26 4.1 9 18 12 6 x 32 27 Dimensions other than those listed above are the same as for the standard type. 6 -XC18 NPT finish piping port Specifications CXS XC18 Bore size Stroke Auto switch Slide bearing
-600 20-600 :J2 35 86 11 5 '/, Y. 64 20 40 10 95 17 27 59 13 12 MaX 1 25 7 30 80 20 40 10 102 17 26 67 18 15 Ml0Xl .2S 25 52 14 11 3 21 30 72 23 17 M1 2X 175 30 52 14 124 21 31 76 25 19 M12X1.75 7 40 99 80 1 750 20750 37 40 102 129 'I.
Segeltorp Switzerland SMC Pneumatik AG (41) 52-396-3131 Dorfstrasse 7, Postfach 117 CH-8484, Weisslingen United Kingdom SMC Pneumatics (U.K.)
Documents HRL Series 8-14 HRX-OM-Y098 Chapter 8 Documents 8.9 Sample Sample Doc. HRL Series Documents 8-15 HRX-OM-Y098 Chapter 8 Documents Mfg. code Model no.
Connector C Actuator side (Terminal no.) 1 2 5 6 (14) (18) 8 A1 B1 (13.5) (17.7) (17.7) Cable length (L) 1 3 5 8 A B C 1 2 A6 B6 1.5 m 3 m 5 m 8 m (30.7) Connector A 5 6 (14.7) Connector D L (11) (10) 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) Controller side 10 m (14.2) Connector C (Terminal no.) 1 2 5 6 15 m 5.5 6.3 Actuator side (14) (18) (Terminal
175, 200 50.5 75.5 50.5 52.5 39 41 10 10 0 25 23 9 2.5 25 50.5 77 50.5 53.5 37.5 40.5 10 14 0 26.5 23.5 10 3 Bore size [mm] G GA GB GC H HA J K L MM ML NN OA OB OL P PA PB PW Q 100 st or less Over 100 st Nil TN TF 12 25 10 6 7 10 54 M5 12.5 12.5 17 M4 x 0.7 10 M4 x 0.7 4.3 8 4.5 M5 x 0.8 11.5 8 16 14 16 29 12.5 5.5 7.5 11.5 59 M3.5 14.5 14.5 20 M5 x 0.8 11 M5 x 0.8 4.3 8 4.5 M5 x 0.8 11.5
Auto switch model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Dimensions D-M9 Auto Switch Internal Circuit Mounting screw M2.5 x 4 L Slotted set screw D-M9B, N, P D-M9N Indicator light DC (+) Brown 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black 2.7 2.8 4 22 DC () Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC (+) Brown 22 3.2 D-M9B (
Mass (g) Auto Switch Internal Circuit D-M9N D-M9P D-M9B Auto switch model 0.5 8 8 7 D-M9N 1 14 14 13 Lead wire length (m) DC (+) Brown 3 41 41 38 5 68 68 63 Main circuit of switch OUT Black Dimensions (mm) DC () Blue D-M9l M2.5 x 4 l Slotted set screw D-M9P DC (+) Brown Indicator light 2.6 Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC () Blue VNA D-M9B VNB 3.2 OUT
Lifting force = Theoretical lifting force / t Theoretical lifting force (Theoretical lifting force = P x S x 0.1) Cup diameter (8 to 32) [N] Cup diameter [mm] 8 10 13 16 20 25 32 S: Cup area [cm2] 0.50 0.79 1.33 2.01 3.14 4.91 8.04 -85 4.2 6.6 11 17 26 41 68 -80 4.0 6.2 10 16 25 39 64 -75 3.7 5.8 10 15 23 36 60 -70 3.5 5.5 9.3 14 22 34 56 Vacuum -65 3.2 5.1 8.6 13 20 31 52 pressure -60 3.0
Auto switch model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Dimensions D-M9 Auto Switch Internal Circuit Mounting screw M2.5 x 4 L Slotted set screw D-M9B, N, P D-M9N Indicator light DC (+) Brown 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black 2.7 2.8 4 22 DC () Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC (+) Brown 22 3.2 D-M9B (
Up to 400 35 32 75 27 58 18 38 6 11 51 11 M8 x 1.25 7 16 11 M18 x 1.5 22 1/4 73 135 80 Up to 500 40 37 88 32 69 22 45 12 13 62 13 M8 x 1.25 7 19 13 M22 x 1.5 26 1/4 83 158 85 Up to 500 40 37 95 32 74 22 45 12 13 62 13 M10 x 1.25 7 19 14 M22 x 1.5 26 1/4 83 159 100 Up to 500 40 37 110 41 87 26 50 10 14 66 16 M10 x 1.25 12 23 14 M26 x 1.5 28 3/8 88 168 Rod end nut (Standard) 30 d D C H B [mm
(For 4) C6 (For 6) C8 (For 8) Side P kit: Flat ribbon cable 26P 1 to 12 stations 35 580 20P 1 to 9 stations C10 (For 10) 10-SQ231 J kit: Flat ribbon cable PC wiring system compatible 10-SS5Q23-1 to 8 stations 35 580 C4 (For 4) C6 (For 6) C8 (For 8) Note 2) Top 1 to 12 stations L.
22 30 4 4 6 10 14 22 30 4 4 6 10 14 22 30 6 10 16 20 25 32 40 6 10 16 20 25 32 40 6 10 16 20 25 32 40 32, 40 Double acting Normally closed Normally open Single acting 3.7 13 38 57 83 161 267 JIS Symbol Double acting Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at center of stroke.
4 4 6 10 14 4 4 6 10 14 6.1 17 40 66 104 MHZJ2-6D MHZJ2-10D MHZJ2-16D MHZJ2-20D MHZJ2-25D MHZJ2-6S MHZJ2-10S MHZJ2-16S MHZJ2-20S MHZJ2-25S MHZJ2-6C MHZJ2-10C MHZJ2-16C MHZJ2-20C MHZJ2-25C Double acting MHY MHW Single acting type, Normally open Normally closed Normally open MRHQ Misc.
(1) Confirmation of the package content 14 (2) Installation 14 (3) Wiring and connection 14 (4) Power ON alarm (error) 15 (5) Operation pattern setting 15 (6) Trial run 15 3.
Connection thread R M Weight (g) A D L2 L1 (mm) L1 L1 2 x Applicable tubing M M KQGT04-M5 KQGT04-01S KQGT06-M5 KQGT06-01S KQGT06-02S KQGT08-01S KQGT08-02S KQGT08-03S KQGT10-02S KQGT10-03S KQGT12-03S KQGT12-04S 18 23.1 26 4.5 M5 x 0.8 4 10.6 20.5 18 1/8 21.5 25.6 27 6 D 10 A 19 25 39 4.5 M5 x 0.8 L2 6 13 22.5 1/8 22.1 27.5 41 18.8 11 H Connection thread (In case of R) 14 26.5 1/4 29.5 50 12
6 900 11-LEFS40ll-850l 1264.5 1294.5 856 1028 14 6 900 11-LEFS40ll-900l 1314.5 1344.5 906 1078 14 6 900 11-LEFS40ll-950l 1364.5 1394.5 956 1128 16 7 1050 11-LEFS40ll-1000l 1414.5 1444.5 1006 1178 16 7 1050 526