Ui = 28 V li = 225 mA (resistively limited) Pi = 1 W Ci = 0 nF Li = 0 mH 52-SY5000 52-SY7000 52-SY9000 Series 10 to 45C (No freezing) Temperature class T6 Ambient and fluid temperature 10 to 50C (No freezing) Temperature class T4, T5 40C less (at rated) Coil temperature rise 24 VDC (system rated voltage) at 1.1 W Barrier input voltage (non hazardous area) 12 VDC at 0.52 W Coil rated voltage

Useable range 10 10 Load Work piece Useable range 5 5 Fn 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 7 8 9 1 01 11 21 31 41 5 Lo Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B40 CY3B20 Selection example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the cylinder shaft center to the load application point of Lo =

Useable range 10 10 Load Work piece Useable range 5 5 Fn 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 7 8 9 1 01 11 21 31 41 5 Lo Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B40 CY3B20 Selection example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the cylinder shaft center to the load application point of Lo =

A A1 E1 L1 MM U1 L M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 16 Y-G02 Y-G03 Y-G04 Y-G05 34 41 42 56 8.5 10.5 14 18 16 20 22 28 25 30 30 40 10.3 12.8 12 16 11.5 14 14 20 34 41 42 56 8.5 16 25 30 30 40 M8 x 1.25 10.3 11.5 21 I-G02 I-G03 I-G04 I-G05 8 10 18 22 8 10 10 14 8 10 18 22 8 10 10 14 IY-G02 IY-G03 IY-G04 IY-G05 +0.058 0 +0.4 +0.2 0.2 0.4 +0.058 0 20 10.5 12.8 14 25.6 20 M10 x 1.25 +0.058

m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s, .00000 lb, ModelPort sizeMass (Bottom ported)Mass (Rear ported)Leakage02R1/4117 g89 g1 x 10?5 Pa?m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s

/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2 x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew Point Conversion Chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric

Metric size Inch size Stations Symbol Elbow Straight Elbow Note) OUT side Mounting position IN side Straight 6 8 10 8 6 10 4 6 4 6 Elbow Straight Elbow Note) OUT side Mounting position IN side Straight 1 2 3 4 5 6 7 8 9 M 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations Fitting type Symbol Fitting type Symbol 1/4 5/16 3/8 5/16 1

dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2

dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2

102.5 5 14 20 32 10 6 14 22 124 92 114 40 14 7 20 28 134.5 96.5 124.5 50 146 102 14 132 8 20 30 63 CU Bore size (mm) L B + Full stroke RR CW CX+0.2 +0.4 CX CZ RR CL + Full stroke CZ -0.3 -0.1 18 36 10 32 A + Full stroke 18 36 10 40 22 44 14 50 22 44 14 63 10 Series RZQ Auto Switches Proper Mounting Position(For Detection of Piston A Stop Position) and Mounting Height D-A7 D-A80 =U B + First-stage

Note 2 Note 1 M3 10: 2 pcs. ( Hexagon socket head cap screw ( with spring washer )) NOTE Holding with hand so that there will be no gap between SI unit and Air supply/exhaust block assembly, tighten the bolts.

Flow Rate and Sonic conductance AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 0.28 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 8 1/4" 5/16" 460 1.3 6 10, 12 8 6 6 10 2 Flow Direction Symbol on Body Tube O.D.

A quick recovery time indicates little liquid pool. 50 Ratio of resistance [k m] Particle ratio [number/cc] PFMC 100 2 or 3 particles/cc PFMV 10 00 10 20 30 40 50 60 70 PF2A 1 0 5 10 15 20 25 30 Duration of flow [min] Duration of flow [hour] PF3W The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room

Internal data error. 16-3-10 10 Series PSE530/200 Multi-channel Controller/Pressure Sensor Operation 1: Initial Setting 1 Channel selection MPa kPa OUT1 OUT2 CH 1 2 3 4 CH2 CH3 CH4 CH1 PRESSURE ZSE ISE SET PSE SET button and hold for 2 seconds or longer.

Nm N M1 M M3 W W2 W W4 ML2B25 10.0 1.2 3.0 200.0 58.0 65.0 100.0 ML2B32 20.0 2.4 6.0 300.0 80.0 96.0 150.0 ML2B40 40.0 4.8 12.0 500.0 106.0 140.0 250.0 ML2B25 ML2B32 ML2B40 J 0.43 0.68 1.21 18 ML2B/M1 ML2B/W1 ML2B/W1 0 0 0 Nm 0 0 0 N N 0 m/s m/s m/s ML2B/M2 ML2B/W2 ML2B/W2 N m N N m/s ML2B/M3 m/s m/s 20 ML2B/W3 ML2B/W3 10 Nm 5 3 2 1 N N m/s m/s m/s ML2B/W4 500 N 00 N

14 18 22 Applicable cylinder bore size (mm) ND NX Applicable pin Part No. 32, 40 50, 63 10 14 18 22 IY-G04 IY-G05 Part No.

ZSE6 ISE6 8 10 ZSE3 ISE3 l50 l45 l48 56 70 4.5 (MAX.8) 35.5 12.5 GS PS ISA 9 8 7 6 10 ZSE1 ISE1 17 10-M3 ZSE2 ISE2 11 23 6 38 50 ZSP 48 (54) ISl ZSM DIN rail L PFl 7.5 10 25 5 IFl 4.5 35 27 Material: Aluminum Part number of DIN rail Part number ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 L 105 140 175 210 245 280 315 3.1-14

Option J: With drain guide Bracket (Option) female thread T: With element service indicator Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35

Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110

to 40 Parallel style MHZL2 10 to 25 Wide type MHL2 10 to 40 Parallel style MHS2 (2 fingers) 32 to 63 Auto switch mounting screw Parallel style MHS3 (3 fingers)/MHS(L)3 32 to 63 Parallel style MHS4 (4 fingers) 32 to 63 Auto switch Angular style MHC2 10 to 25 1.