Dust-tight, Jet-proof Enclosure: Enclosure: Optional IP65 rating Optional IP65 rating Cylinder operation speed Cylinder bore size mm Valve width mm Cv Rubber seal (Metal seal) Cylinder speed mm/s Individual wiring style
(Refer to Design and Selection on Specific Product Precautions.) 200 VAC (50/60 Hz) J1 J2 Note 1) 3 Note 3) Normally closed None 110 VAC (50/60 Hz) 4 Note 3) Normally open None 220 VAC (50/60 Hz) Q1 Q2 N1 N2 5 6 Latching positive common Normally closed 24 VDC Latching positive common None 12 VDC Latching negative common Normally closed Note 3) CE compliant products are not available for
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Performance Curves/Built-in Solenoid Type/Air Operated Type 1l/min = 0.035SCFM 1MPa = 145psi Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting
5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature C
7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I
Tightening Torque for Piping Connection thread Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/2 Rc2 Rc2 1/2 Rc3 Proper tightening torque Nm 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 48 to 50 4. When connecting piping to a product Avoid mistakes regarding the supply port etc. 5.
(50 to 250) Pad diameter (mm) -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa Lifting force (N) Lifting force (N) How to read the graph Example: Workpiece weight 1 kg (Lifting force: 9.8 N) : Conditions/Number of pads: 5 pcs.
Lubrication Dustproof [Degrees of protection 0] (4) VZ Enclosure Shock/Vibration resistance (m/s2) Electrical entry 150/50 (5) Grommet, DlN terminal VT Standard 100, 200 VAC, 50/60 Hz; 24 VDC 220, 110, 48, and 24 VAC (50/60 Hz) 100, 48, and 12 VDC Coil rated voltage VP Option 15 to 10% of rated voltage Allowable voltage fluctuation Coil insulation type VG Class B or equivalent (130C) (6)
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
Please contact SMC in this case. 356 Series MGG Guide Cylinder Specifications JIS Symbol Standard Stroke Model (Bearing type) Long stroke (mm) Standard stroke (mm) Bore size (mm) 20 75, 100, 125, 150, 200 250, 300, 350, 400 25 350, 400, 450, 500 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 MGGM(Slide bearing) MGGL(Ball bushing bearing) 75, 100, 125, 150, 200, 250, 300 50
AC(50/60Hz) 1.2/1.3 1.2/1.3 1.2/1.3 1.5/1.5 3.4/3.0 3.4/3.1 Power consumption (Note 2) W 100V AC,200V AC (50/60Hz) 180/202 180/202 180/202 180/202 180/202 208/236 385/440 420/480 100V AC 10A Circuit Breaker (Note 3) 200V AC 5A 10A Condenser Plate fin tube type with forced air cooling Refrigerant R134a (HFC) Refrigerant Charge(AC100V/200V) g 705 115 5 150 5 180 5 200 5 250 5 260 5 350 10
(C) IDF 1D 30 35 40 50 25 IDF 2D to 240D 30 35 40 45 50 Outlet air press. dew point (C) Ambient temp.
The power supply cable shall be connected properly in accordance with 9.4.2 Power supply cable Electrical specifications of the power supply HED003 AC180-242V, 50/60Hz, 3A max. Single phase 2-wire type + GND (PE) line HED005 AC180-242V, 50/60Hz, 5A max. Single phase 2-wire type + GND (PE) line HED007 AC180-242V, 50/60Hz, 14A max.
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Other (1) : Option Note 1) Except for large flow capacity style.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
ULTIC ARMOR is a registered trademark of Nippon Valqua Industries, Ltd. 469 b XLAQ Series Specifications XLAQ-16 XLAQ-25 XLAQ-40 XLAQ-50 Model Flange (valve) size 16 25 40 50 Valve type Normally closed (Pressurize to open, Spring seal) Fluid Inert gas under vacuum Operating temperature (C) 5 to 60 (High-temperature type: 5 to 150) Atmospheric pressure to 1 x 10-6 Operating pressure (Pa) (
configuration 12 Base 13 Remote 14 Definition and terminology 15 Assembly 17 Mounting and Installation 20 Installation 20 Model Indication and How to Order 23 Summary of Product Parts 24 Connector (Base only) 25 LED Display 26 LED indication of base 26 LED indication of remote 28 Setting and Adjustment 29 Setting 30 Dimensions 46 I/O Map 48 I/O mapping 49 I/O mapping order of base/remote 50