-) ,ON/OFF 27 - OUT1 , AP1 OUT1 OUT1 OUT1 A1L A1H P_1H_1 (n_1H_1) P_1=A-(A-B)/4 A= H_1=|(A-B)/2| B= 1 28 - [F 6] 5R.D. <> [F 6] [FSC] 1 [F 6] 29 - [F11] <> [F11] , 1000 100 [F11] [MPa]/[kPa]/[kgf/cm 2]/[bar]/[psi]/[inHg] 2]/[bar]/[psi]/[inHg]:) ([kgf/cm 21 -[F 0] 30 - [F80] 30 ,OFF <> [F80] 1 2 2 1 [F80] 1,OFF 1 2,30 () 2 OFF ON 31 - [F81] , <> [F81] [

Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. To select one with the maximum air flow rate line that is located above the obtained intersection point A, the model will be AFF37B.

Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AMG650 is obtained when the max. flow line is above the point of intersection A in the graph. HA AT Max. air flow rate (m3/min (ANR)) ID Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A9 D-M9 22 (24.5) A 2.8 0.5 W B ( ): Dimensions for D-A93 Bore size (mm) D-A9 A B W 6 10 16 36 11.5 9.5 (7) D-M9 A B W 29.5 5.5 3.5 (1) 29.5 9.5 7.5 (5) 33.5 9.5 0.5 33.5 13.5 3.5 40 15.5 5.5 20 41 15 13 (10.5) 45 19 9 25 40.5 16.5 14.5 (12) 45.5 20.5 10.5 Note) The above mentioned values are indicated as a guide for auto switch

(Note) Indicator oanel Denatured PPO Swagelok* IS a registered trademark 0 1 Crawford Fitting Co. VCRlI lS a registered trademark. of Cajon Co.

Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AMH650 is obtained when the max. flow line is aboveabove the point of intersection A in the graph. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.

(mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.

Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100

Series ID/IDW/IDA Heatless Air Dryers High Capacity Heatless Air Dryer Series IDA 73 86 114 170 205 295 409 591 818 1136 1909 2273 2955 4091 lbs Kg Weight 160 190 250 375 450 650 900 1300 1800 2500 4200 5000 6500 9000 A B C inch mm inch mm inch mm 610 610 711 787 813 838 1067 1168 1245 1524 1575 1575 1219 1575 24 24 28 31 32 33 42 46 49 60 62 62 48 62 711 864 813 940 914 1041 1143 1448 1524

ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 Manifold Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 ZFA200 1 8 1 4 Number of manifold stations Symbol Single unit Note) Model 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10

ZFB100, ZFB101 ZFB200, ZFB201 ZFB300, ZFB301 ZFB401 16 x 14 x L60 rZFB200-08 tZFB300-08, -10 ZFB301-11, ZFB401-13 I-34S-A 10 x 6 x L33 12 x 8 x L42 14 x 10 x L45 I-35S-A I-36S-A I-39S-A 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. yZFB401-13 Note) Elements and O-rings for the cover are sold in sets of 10 pieces each. 10 pcs.

_ _ __ J Precautions Construction/ Parts List Piping (DBe sure to apply a wrench to the metal seclion (17mm) during piping. Never apply a wrench to the resin section of the main unit. , ::g}Clean tube fittings by air-blow (0 remove foreign matter from inside. Operating conditions This SWitch is not of a waterproof type. Wipe the switch splashed with waler or oil.

MHT2-63D L = 180 mm Warning Maintenance If a workpiece is to be gripped by using the toggle, make sure to periodically check that the workpiece has not shifted during the acceleration of the movement. If the workpiece is not gripped in a stable manner, it could shift or drop and create a dangerous situation.

MHT2-63D L = 180 mm Warning Maintenance If a workpiece is to be gripped by using the toggle, make sure to periodically check that the workpiece has not shifted during the acceleration of the movement. If the workpiece is not gripped in a stable manner, it could shift or drop and create a dangerous situation.

V] F.S.=514[V] (1%F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1 k 1 M A/D 5 V A/D 5(V)1(M)/(1(k)+1(M))4.995(V)0.005V ) Ripple -8No.PS-OME0003CN-F 1 (DC+) 2 3 (DC-) 4 (IN15 V) A A PSE200/PSE300 (ZS-28-C) M() 37104-3101-000FL Tyco Electronics() 3-1473562-4 () XN2A-1430 () -9No.PS-OME0003CN-F PSE200 PSE300 15V 1 k () -10No.PS-OME0003CN-F (A/D ) () 20 2030 -11No.PS-OME0003CN-F PSE530 PSE531

V) 5 Current consumption 25 mA or less (64.5) 0.7 (4) Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less Heat resistant heavy-duty lead wire 3000 (5000) Leakage current 100 A or less at 24 VDC 3.4 3.4 Indicator light Operating range Red LED lights up.

P101. 2 CG5 N A (mm) E max (J) E max (J) 2 E=(m/2)v 20 0.28 0.42 25 0.41 0.65 E J m: (Kg) v m/s 32 0.66 0.91 40 1.2 1.8 50 2.0 3.4 EE max (J) 63 3.4 4.9 80 5.9 11.8 100 9.9 16.7 (2) 2-7. 14 28. 3 13 2 3CDG5 (M4 1~1.2Nm 3 3.

Improved corrosion resistance with the adoption of a stainless steel, plate type, heat exchanger.

A L1 Applicable tubing O.D. d 0 0 5 10 AS-DPP00092 AS-DPP00093 4 6 19.4 16 46.9 43.5 42.7 39.3 Number of needle rotations 624