The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 15.39561 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 25MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 8.10198 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 29.05141 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Normal output Flow setting Sets the ON and OFF point of the switch output. 1500 L/min Hysteresis Appropriate setting of the hysteresis will prevent the switch output from chattering. 150 L/min Delay time Delay time of the switch output can be selected. 0.00 s Output ON: Green Display colour Select the display colour.
Designated nozzle: IBG1-12-10: Nozzle length (50, 100, 150, 300) Silencing nozzle: IBG1-12S Set including the designated nozzle and silencing nozzle: IBG1-12-10-S : Nozzle length (50, 100, 150, 300) 4. Impact resistance of the product is 150[m/s2]. Vibration resistance is 30[m/s2]. Avoid applying vibration exceeding the allowable value to the product. Mounting Warning 1.
Description Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 105 105 (5) Size: Perform setting as shown below.
No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12
Connection Parameter Assembly Instance values: Description Decimal Comm Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 1 1 Size: Description Size Comm Format "Data-INT" "Data-SINT" Input 3 words 6 bytes Output 2 words 4 bytes Configuration 0 word 0 byte -19No.EX-OMK0004-B Maintenance How to replace SI unit Remove screws mounted on the end plate, and separate it from
Outer dimensions and descriptions of each part 4Outer dimensions and descriptions of each part 1) Outer dimensions Model HAA15-10 HAA22-14 PORT SIZE 1B union 11/2B union A 460 588 B 394 484 C 33 52 D 70 70 E 59 60 F 485 580 G 428 505 H 320 333 J 150 150 K 150 150 L 320 400 M 70 94 N 58 65 P 200 200 Q 480 610 R 220 220 S 225 238 HAA Series 6 4 1) Outer dimensions ATX-OM-F004E Air-Cooled Aftercooler
1.65 2.24 2.46 2.87 3.28 3.69 4.10 4.51 50 MGQM50 2.54 3.09 3.65 4.21 4.77 5.33 5.89 6.5 63 MGQM63 3.01 3.63 4.23 4.85 5.47 6.09 6.71 7.3 80 MGQM80 5.66 6.59 7.49 8.41 9.33 10.3 11.2 12.1 100 MGQM100 8.96 10.3 11.6 12.9 14.2 15.6 16.9 18.2 Ball Bushing MGQL12 to 100 (kg) (mm) Model Standard stroke (mm) Bore size 10 20 25 30 40 50 75 100 125 150 175 200 12 MGQL12 0.23 0.26 0.29 0.35 0.38
NCQ8B106-T-PS NCQ8B106-T-PS 106 (1 1/16") NCQ8B150-T-PS NCQ8B150-T-PS 150 (1 1/2") NCQ8B200-T-PS NCQ8B200-T-PS 200 (2") NCQ8B250-T-PS NCQ8B250-T-PS 250 (2 1/2")
frequency [c.p.m] Weight [g] Model Bore size [mm] MHL2-10DZ 60 20 56 76 280 MHL2-10D1Z 40 40 78 118 355 10 MHL2-10D2Z 60 96 156 430 MHL2-16DZ 60 30 68 98 525 MHL2-16D1Z 40 60 110 170 725 16 MHL2-16D2Z 80 130 210 845 MHL2-20DZ 60 40 82 122 940 MHL2-20D1Z 40 80 142 222 1335 20 Symbol MHL2-20D2Z 100 162 262 1520 Double acting: External grip Double acting: Internal grip MHL2-25DZ 60 50 100 150
When the arms moment of inertia is 1 x 103 kgm2, cylinder speed should be MK20/25: 82 mm/s or less, MK32/40: 150 mm/s or less. For calculating the moment of inertia, refer to page 387. Note) Maximum piston speed is equivalent to approximately 1.6x the average piston speed. (Rough indication) Note) Use 63 within a pressure range from 0.1 to 0.6 MPa.