DFSIIWDJ59W> lmm) DA59W DF5BA:DE5NT (mm) DF5BA A B A B A .B A B A B , 32 0.5 0 4.5 2 7 4.5 11 8.5 12 9.5 , 40 0.5 0 4.5 2 7 4.5 11 8 .5 12 9.5 , SO 1 0 5 2.5 7.5 5 11 .5 9 12.5 10 Ht H~ HI Hs 32 24.S 35 25 32.5 t 40 27.S 38.5 27.5 36.5 I SO 34.5 43.5 34 41 ; 80 4 2.5 6 6 .5 10.5 9 14.5 13 15.5 14 , 100 4 2.5 8 6.5 10.5 9 14.5 13 15.5 14 J 63 39.5 46.5 39 46 '. 63 1 0 5 2.5 7.5 5 11 .5 9 12.5
Dimensions (mm) 1in = 25.4mm MSUA3 MSUA3-S, SE Scale: 70% 8-M4 x 0.7 depth 7 C 58 B 36 44 27 30 4-M4 x 0.7 depth 5.5 22.5 5 +0.025 0 41h9 0 0.062 3H9 A +0.052 0 21H9 Long groove depth 5 (positioning pin hole) 22.5 29 2.5 3 +0.025 0 3-3H9 depth 3 ( A , B , C ) 2-4.5 through 3-R1.5 15.5 45 9 42h9 0 0.062 2 36 3 8 11 8 1.5 5 5 18.3 29 11 Angle adjustment bolt 2-4.5 through 3-R1.5 6 2-M5 x 0.8
Model Model Model Port size Effective area Weight Dimensions (mm) R(PT) (mm2) (g) Model Port size Effective area Weight Dimensions (mm) R(PT) (mm2) (g) AN103-01 10 1 23.5 11 3 36 16 14 17 66 22 19 A B D A B D 1 8 1 4 2504-002 33.9 111 62 30 24 106 64 30 24 113 68 30 24 AN203-02 15 1 4 AN303-03 35 3 8 25 84 25 22 AN403-04 60 1 2 2505-003 45.9 3 8 2506-004 50.0 1 2 310 88.5 48 35 2507-006
Conduit terminal: VP3145-T A B DIN terminal: VP3145-D A B [105] 76 Light (For TL, TZ) 30 31.3 Max.12 G1/2 Applicable cable 6 to 12 Light position (For DL, DZ) G1/2 [196] NO NO 190.6 194 181.5 166 PE PE 26 26 83 83 32 32 36 36 80 80 [ ]: With indicator light (TL, TZ) 1310 Large Size 3 Port Solenoid Valve VP3165 Series Dimensions: VP3165 Grommet: VP3165-G A B 113 87.4 54 30 71 101 G1/2 1
depth 11.5 53 51.5 56 72 74.5 83 30 38 48 5 6 7 5 6 8 M6 x 1.0 M8 x 1.25 M10 x 1.25 5.5 5.5 6.6 16 20 24 13 23.5 29 20, 30, 40, 50, 60, 70, 80, 90, 100 4 Series CU Auto Switch Proper Mounting Positions and Heights for Stroke End Detection D-A9 D-F9 D-F9W A 22 (24.5) 2.8 0.5 B W The dimension in ( ) is for D-A93 type.
This will cause a malfunction. 14-11-6 6 Pressure Gauge Guide How to Order G M C 46 10 01 X2 Option Specifications Symbol Pressure gauge F.R.L.
Body (Material: SCS13) Refer to the page 22 for the maintenance parts. 12 Series XMH, XYH Stainless steel High Vacuum Angle/In-line Valve Dimensions XMH/Angle type C D L2 (KF flange) Fn Fc C (Fc) L1 (CF flange) H J B G A A (mm) Model A 100.5 114 162.5 179.5 B 38 48 66 79 C 1 1 2 2 D 30 40 55 75 Fn 34 70 Fc 17 26 41 52 G 35 40.5 57 70 H 18 21.5 30 35 J P.C.D L1 6-4.4 6-6.6 L2 XMH-16
100 200 205 Inch size M5 standard 1/8 standard 1/4 standard 3.2 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" 4 6 8 Use a 1/8" tube.
Note 6) The flow rate of the body ported product with a built-in silencer decreases by 30%.
60 90 75 40 60 Suction flow 45 20 30 15 0 0 20 40 60 80 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 Suction flow [L/min(ANR)] Supply pressure [MPa] 256 Vacuum Pad with Ejector ZHP Series Construction A-A Component Parts t !
6 6 Tubing Size (Inch) 1/8 x 0.086 1/4 x 5/32 1/4 x 5/32 3/8 x 1/4 3/8 x 1/4 3/8 x 1/4 1/2 x 3/8 1/2 x 3/8 1/2 x 3/8 3/4 x 5/8 3/4 x 5/8 3/4 x 5/8 1 x 7/8 1 x 7/8 1 x 7/8 Thread Size A A B A B C A B C A B C A B C 1/8" 1/8" 1/4" 1/8" 1/4" 3/8" 1/4" 3/8" 1/2" 3/8" 1/2" 3/4" 1/2" 3/4" 1" Tubing Connection E 1A LQ3 Size Combination Class Fitting Style Symbol E T P U Combination 1 2 3 4 5 6 Tube
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 42 52 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 56 65 Two mounting screws (for mounting
16 No.ZL3-OM00801-A 7.2 1 (/) ZL3/ZL6 ZL3-JSY3140-5LZ -a 1 3) 2) DC24V 1) 300mm 300mm * *0.150.18Nm 2) D: E: 1 1 1 1 3) 1 1 2 X12 ZL3/ZL6 SY100-30-4A-6 1 2) / 1) 2) 300 4 DC24V 6 600 10 1000 15 1500 20 2000 25 2500 30 3000 50 5000 ZL3/ZL6 SY100-30-A *x2 17 No.ZL3-OM00801-A ZL3/ZL6 ZS-39-5G ZL3-LW1-N-A 1 1) N NPN P PNP 2 ZL3/ZL6 ZL3-EJ1-H-A 1 2) 1) M 0.35 MPa
764 30 25 (1B) 210 645 750 772 30 40 A Elements Sintered Metal/Fiber Nonstandard elements of the FQ1 series can also be used commonly.
port pressure (MPa) A port pressure (MPa) A port pressure (MPa) 0.6 0.6 0.6 0.4 0.4 0.4 0.2 0.2 0.2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VY1D00-5 VY1B0-5 VY120-5 1 V V V 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 A VY1D00-6 VY1B0-6 VY120-6 A 1 1 1 1 V V V 0 2.5
HHH is 6 displayed. (1) Reset applied pressure (1) Check that the pressure is not LLL is to a level within the set pressure range.
(A-B)/4 n_1=B+(A-B)/4 A= H_1=(A-B)/2 H_1=(A-B)/2 B= 1 -34No.PS-OMS0006CN-G [F 6] 5R.D. <> [F 6] [F 6] -35No.PS-OMS0006CN-G [F10] <> [F10] OFF 2 OUT1 [dUAL]2 [dUAL]2 () () 37 () () () 37 () [F10] -36No.PS-OMS0006CN-G <> (OFF) [F10 ] OUT1 OUT1 OFF n_1 () [F10 ] OUT1 OUT1 OUT1 n1H n1L 2 2 ( ) OUT1 OUT1 ( ) OUT1 () ( ) OUT1 () OUT1 OUT1 OFF -37No.PS-OMS0006CN-G RAnG
/40 Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e C SM 2 OUT A A IN OUT t A-A BLEED w y Note Component Parts Material No.
stroke of 25 mm or less RZQ MI W S B A CEP1 CE1 CE2 [mm] Proper Mounting Position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F ML2B D-M9 D-M9V D-F9W D-F9WV D-A79W D-A9 D-A9V C J G5-S D-A7,A80 D-F9BAL D-P5DWL Bore size (mm) CV B A B A B A B A B A B A B A MVGQ 32 27 37.5 27.5 38 24.5 35 26 36.5 30 40.5 29 39.5 40 CC 27 39 31 43 31.5 43.5 28.5 40.5 30 42
bore size D-P5DW 40, 50, 63 B + First-stage stroke =U =U Mounted on different side in case of a full stroke of 25 mm or less B A [mm] Proper mounting position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F D-F9 D-F9V D-F9W D-F9WV D-A79W D-F7LF D-A9 D-A9V D-F9BAL D-P5DWL D-A7,A80 Bore size (mm) A B A B A B A B A B A B A B A B 32 29 39.5 30 40.5 26 36.5 31.5