Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
) (in) D-B5 D-B6 D-C7 D-C80 D-C73C D-C80C D-B5 D-B6 D-C7 D-C80 D-C73C D-C80C D-B59W D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-B59W D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-H7LF D-G59 D-K59 D-H7LF D-G59 D-K59 Auto switch model Auto switch model B 0.42 0.31 0.52 0.51 0.56 0.83 B 0.86 0.59 0.76 0.85 0.75 1.20 A 0.94 0.78 1.00 1.23 1.13 1.58 A 0.94 0.78 1.00 1.23 1.13 1.58 B 0.50 0.39 0.60 0.59 0.64 0.91 B
Digital flow switch Air combination Spacer Spacer with bracket Pipe adapter PF3A801H AC30#-D Y300-D Y300T-D E300-#03-D PF3A802H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). -20No.PF-OMY0005-A
Filtration efficiency 99.9% Membrane FGH200 to 300 0.2 m EB ES X40 0.4 m Port size Element classification Note) 03 04 06 10 Rc3/8 Rc1/2 Rc3/4 Rc1 Element HEPO 2 Membrane Symbol J D Note) Refer to pages 70 to 73 for details about specifications, models, dimensions, etc. regarding the elements.
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-02 : E4-03 : E4-04 1 4 3 8 1 2 1 4 1 2 : E6-06 : E6-10 3 4 1 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) in the gauge part number (e.g.
I C o n s t a n t Function Sets integral time used for PID control/ M O D E < 1 5 0 s e c 5.5 How to operate 5-10 A_HEC-OM-K001-1.7 Chapter 5 Operation <6> D constant setting: Mode indication D Constant Default value: 0 sec. Setting range 0.0 to 99.9 sec. Indicated contents D constant (Derivative time) D Constant indicates that it is D constant setting mode.
U side D side B B Note) Do not enter the SI Unit part number and the end plate part number together.
A [mm] Weight [g] 01 50 mm IBG1-12-10-50 57 35 02 100 mm IBG1-12-10-100 107 40 03 150 mm IBG1-12-10-150 157 45 04 300 mm IBG1-12-10-300 307 59 11 Long nozzle with a silencer Long nozzle 50 mm IBG1-12-10-50S 72 57 12 100 mm IBG1-12-10-100S 122 62 13 150 mm IBG1-12-10-150S 172 67 14 300 mm IBG1-12-10-300S 322 81 Long nozzle Long nozzle with a silencer IBG10_11/With fitting Symbol Type Applicable
m) Pressure Clas Clas Clas concentration dew s (mg/m3) 0.1 d 0.5 0.5 d 1.0 1.0 d 5.0 point(oC) 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 Not specified 90,000 1,000 3 -20 3 1 4 Not specified Not specified 10,000 4 +3 4 5 5 Not specified Not specified 100,000 5 +7 6 +10 3.3.2 Air pressure 1) Operation with a pressure exceeding the maximum operating
L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 4.5 16 57 61.5 15.5 10 17 30 5 40 1/8 AS2000E-02 4.5 20 59 63.5 17 12 23 30 5 40 1/4 AS3000E-02, 03 5.5 26 69 76 20.6 13.25 25 45.5 5.25 56 1/4, 3/8 AS4000E 2-1/4 to 1/2 72 (Max. 80) Effective thread depth 6 15-9-42
10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 32 1-1/4" 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.
R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.
Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VK VZ1120--M5 (Piping: 4 x 1 m) VZ VF AS1301F-M5-04/AN120M5 AS1301F-M5-04/AN120-M5 Speed controller/Silencer VFR
Select the model with air flow capacity exceeding the calculated corrected air flow from data D of the table below.
(mm) A B C D E F G H J L Port size Bracket part no.
Mode button 1s Set button 1s or Mode button 1s Set button 1s B D C Fig. 40 No.DIG-31900-OM002 49 B Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-1 C Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-2 D Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant
diagram VK VK Surge voltage supressor (Built-in terminal) LED VT R D LED R R NL Markings For AC, 12 VDC or less For 24 VDC or more + 1 2 1 2 1 2 NL: Neon light R: Resister LED: Emitting diode R: Resister D: Protective diode LED: Emitting diode R: Resister 1429
-40 10 -20 -20 5 0 0 0 0.2 0.3 0.4 0.5 0 1 2 3 4 5 6 [MPa] [L/min (AMR) ] ZQ07A 0.43MPa -100 40 -100 35 -80 [L/min (AMR) ] -80 [L/min (AMR) ] 30 [kPa] [kPa] -60 25 -60 20 -40 -40 15 10 -20 -20 5 0 0 0 0 2 4 6 8 10 12 0.2 0.3 0.4 0.5 [MPa] [L/min (AMR) ] ZQ10A 0.43MPa -100 70 -100 60 -80 [L/min (AMR) ] -80 [L/min (AMR) ] [kPa] [kPa] 50 -60 -60 40 -40 30 -40 20 -20 -20 10 0 0 0