Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 11 (10 to 100 L/min), Port Size, Pipe O.D.: 25 (Port Size: 25A, Pipe O.D.: 32mm), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 11 (10 to 100 L/min), Port Size, Pipe O.D.: 25 (Port Size: 25A, Pipe O.D.: 32mm), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate)
Flow Adjustment Valve: With Valve, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specifications: PNP, Analog 4 to 20 mA, Option 1: No Lead Wire, Unit Specifications: Unit Selection Function, Option 2: With Bracket, Calibration Certificate: -
Flow Adjustment Valve: None, Port Size: G1/4, Piping Entry Direction: Straight, Output Specifications: PNP, Analog 4 to 20 mA, Option 1: No Lead Wire, Unit Specifications: Unit Selection Function, Option 2: With Bracket, Calibration Certificate: -
Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specifications: PNP, Analog 4 to 20 mA, Option 1: No Lead Wire, Unit Specifications: Unit Selection Function, Option 2: With Bracket, Calibration Certificate: -
Flow Adjustment Valve: With Valve, Port Size: Rc1/4, Piping Entry Direction: Straight, Output Specifications: PNP, Analog 4 to 20 mA, Option 1: No Lead Wire, Unit Specifications: SI Unit Only, Option 2: -, Calibration Certificate: -
Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 10 to 1000 L/min, Thread Type: Rc, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 20 to 2000 L/min, Thread Type: NPT, Port Size: 3/4, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: SI Unit Only, Option 2: No Bracket, Calibration Certificate: Yes
Rated Flow Range: 5 to 500 L/min, Thread Type: G, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: SI Unit Only, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 20 to 2000 L/min, Thread Type: G, Port Size: 3/4, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: SI Unit Only, Option 2: -, Calibration Certificate: -
Rated Flow Range: 20 to 2000 L/min, Thread Type: G, Port Size: 3/4, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: SI Unit Only, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 5 to 500 L/min, Thread Type: G, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: SI Unit Only, Option 2: -, Calibration Certificate: -