60 90 75 40 60 Suction flow 45 20 30 15 0 0 20 40 60 80 100 0 0 0.1 0.2 0.3 0.4 0.5 0.6 Suction flow [L/min(ANR)] Supply pressure [MPa] 256 Vacuum Pad with Ejector ZHP Series Construction A-A Component Parts t !
H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.
Note) Tighten within the tightening torque of 0.5 Nm 20%. Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing r and a terminal block e. 1.
DB, E dimensions MLGPL (ball bushing)/A, DB, E dimensions A E A E Bore size (mm) Bore size (mm) DB st50 50
Specifications Model Nominal thread size Allowable axial force [N] Allowable eccentricity U [mm] Rotating angle [] Operating temperature range JT20 M8 x 1.25 220 0.5 2 10 to 70C JT32 M10 x 1.25 560 0.5 2 JT40 M14 x 1.5 880 0.75 2 Operating range Center of sphere e g 2 n a Center of axis r U U g n ti a 2 r e p O Applicable Cylinder Model Applicable cylinder *1 Recommended cylinder Bore size
A 32 40 50 63 80 100 125 Table 1 Air cushion 2.2 2.8 4.6 7.8 16 29 45 Allowable kinetic energyJ Non cushion 0.15 0.33 0.56 0.91 1.50 2.68 3.57 C a u t i o n When the product is equipped with a rubber bumper, note that there will be a slight bounce at the stroke end. 9 2-7. Cushion C a u t i o n Cylinder cushions are adjusted properly at the time of shipment.
, HNBR 9 Body Aluminum die-casted 799 IR1000-A/2000-A/3000-A Series Construction Basic type (Knob): IR10l0-A r r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000
Brown 2 A B-1 Red 1 A A-1 Cable length (L) Orange 6 B B-2 Yellow 5 B A-2 8m *1 8 Green 3 COM-A/COM B-3 10m *1 A Blue 4 COM-B/ A-3 Shield 15m *1 B Cable color Terminal no. Vcc B-4 Brown 12 *1) produced upon receipt of order. 20m *1 C GND A-4 Black 13 A B-5 Red 7 A A-5 Black 6 B B-6 Orange 9 Only Robotic type cable can be B A-6 Black 8 3 selected.
View port View port G1/2 Refer to page 529 for Microswitch for differential pressure indication switch. 504 A Suction Filter with Case FH99 Series Dimensions Differential pressure indication switch Blanking cap Differential pressure indicator 8 x T 16 (65) N I (34) E F U OUT X H O 62 B U U R S 4 x K OUT OUT Q P IN Differential pressure indicator Differential pressure indication switch G
The number of sampling locations NL = (A) 0.5 Evaluation method using a simple sampling Number of sampling w Unidirectional airflow: at least two locations Smaller value between NL=A/2.32 and NL=A x 64/(10M) 0.5 locations At least one location 2 litters or a sufficient volume of air that a minimum of 20 particles could be counted if the particle concentration were at the class limit.
Material Note PBT PBT Description Body A Body B Needle Seat ring Spring U seal Cassette Seal O-ring O-ring O-ring O-ring Gasket 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Body A Elbow body Body B Needle Seat ring Spring U seal Cassette Seal O-ring O-ring O-ring O-ring O-ring Electroless nickel plated Electroless nickel plated Electroless nickel plated Brass
A A B A B A B A B A B A B 122.3 4 A SMC 53.6 2 B 37.6 18.5 Approx. 12 Approx. 12 EXH. outlet Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) Triangle mark indicator position Approx. 10 D side U side Station 1 2 3 4 5 6 7 8 n C10: R(EXH) port For top ports C10: P(SUP) port 4 A 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A R 62 41.5 (58) 39.5 P B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 25.5
Lock keys ( ref er t o P8) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 90% 100% 120% 100% 0% 0% 10% 20% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 20% t o 90% of t he rat ed val ue. ( D EFAU LT VALU E: 0% ) ( N ot e 2) : The pressure of l ess t han 0%
H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.
/s2] We = 5 x 103 x m x g x U Pich moment Me1 = 1/3 We (L + B) 103 Yaw moment Me3 = 1/3 We (L + A) 103 (mm) Average load coefficient Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 Me3 Me1 We We L A L B Cylinder central axis Guide shaft mounting surface Guide central axis 8-17-4 Series CYP Model Selection 2 Selection Calculation The selection calculation finds the load factors (n) of the
by the load equivalent to impact at the stroke end We: Load equivalent to impact [N] m : Load mass [kg] U: Max. speed [mm/s] g: Gravitational acceleration [9.8 m/s2] We = 5 x 103 x m x g x U Pich moment Me1 = 1/3 We (L + B) 103 Yaw moment Me3 = 1/3 We (L + A) 103 (mm) Average load coefficient Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 Me3 Me1 We We L A L B Cylinder central axis Guide
40 60 80 100 Load N 0 20 40 60 80 100 Load N 0 50 100 150 200 250 Data 8-9-9 9 Series MXY Table Deflection Table deflection due to pitch moment load Displacement at A when load is applied F Table deflection due to yaw moment load Displacement at A when load is applied F Table deflection due to roll moment load Displacement at A when load is applied F A A F A F F L L L L dimension mm L dimension
250 L/min ) [cm] -38No.PF-OMN0009CN-F PF3W504S PF3W520S [] [] P: P: PF3W540S [] P: -39No.PF-OMN0009CN-F () (PF3W504/520/540) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521
Cracking pressure is a pressure at which the valve starts opening and not a pressure at which the valve is fully open. 15-8-7