[F 3] Digital filter setting completed 1: Each set value is a guideline for 90% response time. 2: Both the switch output and pressure display are affected.
[F 3] Digital filter setting completed 1: Each set value is a guideline for 90% response time. 2: Both the switch output and pressure display are affected.
[F 3] Digital filter setting completed 1: Each set value is a guideline for 90% response time. 2: Both the switch output and pressure display are affected.
[F 3] Digital filter setting completed 1: Each set value is a guideline for 90% response time. 2: Both the switch output and pressure display are affected.
[F 3] Digital filter setting completed 1: Each set value is a guideline for 90% response time. 2: Both the switch output and pressure display are affected.
Applicable strokes: 450, 550, 650, 750, 850, 950 Example) LG1H2021PC-550-F2-X2 500 8.5 13.3 600 9.3 14.5 700 10.1 15.8 800 10.9 17.1 900 11.7 18.3 1000 12.5 19.6 mm kg kg Standard stroke Aluminum Stainless steel Body weight Operating temperature range 5 to 40 (with no condensation) 30 90 C kg N mm/s mm Work load Rated thrust Maximum speed Note) Performance 1000 1000 930 740 600 500 Positioning
or less (No condensation) 20 to 65 (No freezing) 90 or less (No condensation) Between case and SG: 10 (500 VDC) 600 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 Model Compatible motor capacity [W] 100 200 100 200 Absolute 18-bit encoder Compatible encoder (Resolution: 262144 p/rev) Three phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Single phase 100 to 120 VAC (50/60 Hz) Single phase 200
90 256 1 for L5 255 1 for L3 General purpose input no., State AND input time out subroutine call command C-AND (P-no.) label General purpose input no., State OR input time out subroutine call command C-OR (P-no.) label General purpose input no., State AND input condition jump command J-AND (P-no.) label Condition jump General purpose input no., State OR input condition jump command J-OR
Description 73.6 1 24 V (for output) 56.6 2 1 2 0 V (for output) 3 24 V (for control/input) 5 30.2 4 0 V (for control/input) 4 3 13.2 5 FE EX600-ED3 42.5 5.5 26 20.5 8 106 90 30.35 Power supply connector PWR: 7/8 inch 5-pin plug 56.6 Configuration Pin no.
348 20 285.5 303 325 335.5 19 274 291.5 312.5 323 18 262.5 280 300 310.5 17 251 268.5 300 310.5 16 239.5 257 287.5 298 15 228 245.5 275 285.5 14 216.5 234 262.5 273 13 205 222.5 250 260.5 12 193.5 211 237.5 248 11 182 199.5 225 235.5 10 170.5 188 212.5 223 9 159 176.5 200 210.5 8 147.5 165 187.5 198 7 136 153.5 175 185.5 6 124.5 142 162.5 173 5 113 130.5 150 160.5 4 101.5 119 150 160.5 3 90
Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min.
Vertical mounting Cylinder orientation Horizontal mounting Size-up cylinder NO NO Use of external guide Load factor 50% YES YES Size-up cylinder or Use of external guide Size-up cylinder Size-up cylinder Examine lateral load, referring to graph (2) Examine buckling referring to table (1) Load factor 90% NG NG NO OK OK YES Model selected Selection Example 1 Selection Example 2 Actuating
57 XC ZZ 140 174 SW 17 19 TC M8 x 1 Bore 30 0 0.033 +0.036 0 10 32 40 97 122 M30 x 1.5 G 1/8 23.8 12.2 M10 x 1.5 38 0 0.039 +0.043 0 12 M38 x 1.5 G 1/4 28.3 14.2 M12 x 1.75 M10 x 1 ( ): In the case of air cushion With Rod Boot (mm) Item h 1 to 50 77 88 AM C e f K KK Stroke Bore 51 to 100 101 to 150 102 113 151 to 200 115 126 201 to 300 140 151 301 to 400 165 176 401 to 500 190 201 32 40 90
18.5 10 18 12 40 6 33 M5 x 0.8 5.5 8 6 25 59 3 44 60 3.5 M10 x 1.25 29 83 15 7 129.5 1/8 32 to 450 22 19.5 17 44 20 12 18 12 40 6 38 M5 x 0.8 5.5 10 7.2 25 59 3 44 60 3.5 M10 x 1.25 35.5 85 16 6 131.5 1/8 40 to 800 30 27 19 53.5 26 16 19 13 50 8 47 M6 x 1.0 6 14 7.2 30 66 3 54 75 4 M14 x 1.5 44 93 16.5 6.5 150 1/8 50 to 1200 35 32 27 69 32 20 21 14 58 11 58 M8 x 1.25 7 18 10 40 74 4 66 90
18 12 40 6 33 M5 x 0.8 5.5 8 6 25 59 3 44 60 3.5 M10 x 1.25 29 1/8 83 15 7 129.5 32 Up to 450 22 19.5 17 44 20 12 18 12 40 6 38 M5 x 0.8 5.5 10 7.2 25 59 3 44 60 3.5 M10 x 1.25 35.5 1/8 85 16 6 131.5 40 Up to 800 30 27 19 53.5 26 16 19 13 50 8 47 M6 x 1.0 6 14 7.2 30 66 3 54 75 4 M14 x 1.5 44 1/8 93 16.5 6.5 150 50 Up to 1200 35 32 27 69 32 20 21 14 58 11 58 M8 x 1.25 7 18 10 40 74 4 66 90
13223 6.5 20 16 13 3.5 0.3 19.2 20 Z ZZ G (NN 1) x H H 10.5 5.5 10.5 5.5 A B 3H9( ) depth 2.5 +0.025 0 3.2 3.2 6.3 7 7 12 1 A B NN x M4 x 0.7 thread depth 8 4 3H9 ( ) depth 2.5 +0.025 0 HA GA A-A B-B (mm) Model F 22 25 21 26 27 N 4 4 6 6 6 G 6 13 11 21 H 23 26 28 28 NN 2 2 3 3 3 GA 13 13 29 39 49 HA 16 26 20 28 28 I 9 9 9 16 9 J 17 27 37 48 65 K 21.5 31.5 41.5 51.5 61.5 M 42 52 62 80 90
x M3 x 0.5 thread depth 4 (With stroke adjuster at extension end) 2 (Stroke adjuster at retraction end) 23 40 15 30 37 10 3H9 ( ) depth 3 +0.025 0 12 F +0.025 0 3H9 ( ) depth 3 N 1 x F 2 30 24 M 0.5 23 24 Z ZZ (NN 1) x H G H 13 6.5 6.5 13 B A 3.2 6.5 7 7 15 1 3H9 ( ) depth 3 +0.025 0 4 NN x M4 x 0.7 thread depth 8 B A 3H9 ( ) depth 3 +0.025 0 HA GA Section AA Section BB (mm) ZZ 74 79 90
Vertical mounting Cylinder orientation Horizontal mounting Size-up cylinder NO NO Use of external guide Load factor 50% YES YES Size-up cylinder or Use of external guide Size-up cylinder Size-up cylinder Examine lateral load, referring to graph (2) Examine buckling referring to table (1) Load factor 90% NG NG NO OK OK YES Model selected Selection Example 1 Selection Example 2 Actuating
3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70 75 90
Symbol Rotation angle Insulated adapter Pilot port Nil IN OUT 90 Pilot port No XCA 90 Pilot port XCA 270 XCC IN OUT 270 Pilot port 1 (IN) 2 (OUT) XCC OUT IN Pilot port With insulated adapter XA XA Insulated adapter IN OUT 90 XAA 90 270 XAC Yes XAA 1 (IN) 2 (OUT) Pilot port With insulated adapter OUT IN 270 Pilot port With insulated adapter XAC IN OUT * For details about the insulated adapter