The load doesnt work. < Auto switch operating range [mm] / Actuation operating speed [mm/s] -22No.D-S-OMJ0004-G Specifications D-M9B(E)(V)/D-M9N(E)(V)/D-M9P(E)(V) PLC: Programmable Logic Controller Switch part no.

To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.

To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.

Float type auto drain AD44 Pressure gauge (V type only) Case assembly (N.O.)

Tie-rods Head cover assembly 30 Series MNB Selection of Models Step 1 Find the maximum load speed: V Precautions on Model Selection Caution Find the maximum load speed: V(mm/s) from the load movement time: t(s) and the movement distance: st(mm). 1.

12 V 6 V 5 V 3 V 5 6 V S R Lead wire length 0.5 (2.9) m NPN output Analog output PNP output 27 26 67 Lead wire length 0.5 (2.9) m Lead wire length 0.5 (2.9) m Not required for Nil, vacuum adapter (GN) and vacuum pressure gauge (G).

G T L S M kit (Flat ribbon cable with terminal block) kit (Terminal box) kit (Lead wire) kit (Serial transmission unit) kit (Multi-connector kit) Number of pins: 20 (VQ2000 only) 2-4-113 Valve Specifications Sonic conductance Type of actuation Voltage Electrical entry Manual override C [dm3/(sbar)] 4/2 5/3 (A/B R1/R2) 12 V 24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz Push type

2-wire 12 V [] [] 3-wire (NPN equivalent) A96 Z76 5 V IC circuit A93 A90 Z73 Z80 Grommet 100 V Relay PLC 2-wire 12 V 24 V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.

12 V 12 V Reed switch Solid state switch Relay, PLC Grommet Yes 24 V 5 V, 12 V Diagnostic indication (2-color indication) 12 V A96V A96 5 V Yes (NPN equivalent) 24 V Grommet Relay, PLC A93V A90V A93 A90 100 V 12 V 2-wire No 100 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches

[How to JOG] a) Change the mode to Remote mode in the main window. b) From the main window select View (V), select the Teaching window and select the JOG tab. Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window.

DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -19No.PS-OMU0002CN-D Z/ISE20A(F)-S/-R () DC(+) NPN 2 Max.28 V80 mA 1 V R15 V OUT1 1 k OUT2 S420 mA DC(-) 12 V 300 24 V 600 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -20No.PS-OMU0002CN-D -V/-T () DC(+) PNP 2 Max.80 mA 1 V T15 V OUT1 1 k OUT2 V420 mA DC(

collector output type-2 output Max. 80 mA Residual voltage 1 V or less T: Analog output 1 to 5 V Output impedance 1 k V: Analog output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -V/-T (Auto-shift input mode) With auto-shift switch output PNP open collector output type-2 output Max. 80 mA Residual voltage 1 V or less

110 V [115 V] 200 V 220 V [230 V] (R1)5 1 (P) 3(R2) 1 (P) (R)3 AC Apparent power (VA) 2 position double 2 position double 2(B) (A)4 4(A) (B)2 Diode (DIN terminal, Varistor when non-polar types) LED (Neon light when AC with DIN terminal) Surge voltage suppressor Indicator light (R1)5 1 (P) 3(R2) (R)3 1 (P) Common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.

12 V Reed auto switch Solid state auto switch 12 V IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V Relay, PLC Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equiv.)

A96V A96 5 V Grommet Yes 12 V A93 A93V 24 V 100 V Relay, PLC 2-wire 3-wire (NPN) M9N M9NV IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) M9B M9BV 2-wire 12 V F9NW F9NWV Relay, PLC 3-wire (NPN) Diagnostic indication IC circuit 5 V, 12 V 24 V Grommet Yes 3-wire (PNP) F9PW F9PWV (2-color display) F9BW F9BWV Improved water resistance (2-color display) 2-wire 12 V F9BA Though it is possible

A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F P5DW 200 V A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV Grommet Yes 100 V 12 V Relay, PLC 2-wire 24 V Connector 12 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 2-wire 12 V Connector Relay, PLC Yes 24 V 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic output

IC circuit 5 V A76H A96V A96 Yes No A72 A73 A80 A72H A73H A80H 200 V Solid state switch Reed switch Grommet 100 V 12 V IC circuit A90V A93V A90 A93 5 V, 12 V 12 V 12 V Relay, PLC 2-wire No Yes 24 V A73C A80C A79W F7NV F7PV F7BV J79C F7NWV Connector IC circuit 5 V, 12 V Grommet Diagnostic indication (2-color indication) Yes 3-wire (NPN) 3-wire (PNP) F79 F7P J79 M9NV M9PV M9BV M9N M9P M9B 5

Yes Yes Grommet Relay, PLC 12 V 100 V 24 V IC circuit 5 V, 12 V Solid state switch Relay PLC 12 V Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V For 25, 32, 40, 50, 63 Lead wire length (m) Load voltage Electrical entry Auto switch model Pre-wire connector Applicable load Perpendicular (1) In-line Special function Wiring (Output) Type 0.5 (Nil) 3 (L) 5 (Z

IC circuit 5 V Yes (NPN equivalent) A93 A90 A54 A64 A59W A33 A34 A44 IC circuit 100 V 12 V 5 V, 12 V Grommet No Relay, PLC 100 V or less Yes 100 V, 200 V No 200 V or less 2-wire 24 V PLC Terminal conduit 12 V Relay, PLC Yes 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.

Use 0 V as the baseline for the power supplied to this product for output, control and input. +24 V +24 V Output power Output power 0 V 0 V Control/Input power Control/Input power 24 V +24 V 4. Each product needs to be powered by one power supply unit.