SMC Corporation of America
Elite Part Number Search
Search Results "CLA2C100-250-E"

N.C. 125 AC 250 AC 30 DC 125 DC 1.3 0.8 2.5 1.5 0.7 0.5 1.5 1 3 0.05 2 0.05 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 1500 VAC, Hz for 1 min.

Supp Output Flow Rate 8.8 SCFM (250 Nl/min)at 70 psi (5 kgf/cm'?)

Supp Output Flow Rate 8.8 SCFM (250 Nl/min)at 70 psi (5 kgf/cm'?)

Microprocessor-Controlled Electro-Pneumatic Regulator ITV2000 EASY PROGRAMMING GUIDE MICROPROCESSOR-CONTROLLED E-P REGULATOR CONTENTS: ITV2000 1. LAYOUT IDENTIFICATION 2. WIRING 3. INPUT SIGNAL 4. KEY LOCK FUNCTION 5. SET POINT PROGRAMMING 6. ADJUSTING MINIMUM & MAXIMUM PRESSURES 7. MONITOR OUTPUT 8. ERROR MESSAGES 9.

This is a legacy product, and replaced byITV0050-3N, REGULATOR, E/P, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 1A, IT1000 OTHER SPT VERSION, .38904 lb, ModelMinimum supply pressureMaximum supply pressureSet pressure rangeMaximum flow ratePower supplyInput signalInput impedanceOutput signalLinearityHysteresisRepeatabilitySensitivityTemperature characteristicsOperating temperature

Magnet: None, Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: D (Spring/Air Pressure Lock)

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: None, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Material: E (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon/Fluororesin Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)