This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CJ2 ROUND BODY CYLINDER, ET, 10MM CJ2 SGL-ACT AUTO-SW, 0.42714 lb
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.03470 lb
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 200mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: Built-in, Mounting: Double Clevis, Bore: 16mm, Stroke: 125mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: Built-in, Mounting: Double Clevis, Bore: 16mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 125mm, Cushion: A (Air Cushion), Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint), Auto Switch: M9P--Solid State, Gen.
Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 15mm, Cushion: A (Air Cushion), Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9P--Solid State, Gen.
Magnet: D (Built-in Magnet), Series: J2, Mounting: B (Basic), Bore Size: 16mm, Stroke A: 100mm, +: None, Stroke B: None, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen.
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
Heater: 8 XLC Series Dimensions XLC: Air operated (b) E C Size 16, 25, 40 E C E Fn (KF flange) (a) D Auto switch (Option) Heater (Option) (c) H J B A G A (b) C E Size 50, 63, 80 E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) H J K B A G A [mm] Model A B C D E*1 Fn Fd G H J K XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27 12 40 26 44 21 XLC-
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !
Auto switch mounting Auto switch model C85 Series C75 Series Bore size [mm] 8 10 12 16 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V)*7 BJ6-008 (A set of a, b, c, d) BJ6-010 (A set of a, b, c, d) BJ6-012 (A set of a, b, c, d) BJ6-016 (A set of a, b, c, d) BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9lA(V) BJ6-008S (A
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C
Heater: 8 XLC Series Dimensions XLC: Air operated (b) E C Size 16, 25, 40 E C E Fn (KF flange) (a) D Auto switch (Option) Heater (Option) (c) H J B A G A (b) C E Size 50, 63, 80 E C E Fn (KF flange) Fd (K flange) (a) D Heater (Option) Auto switch (Option) (c) H J K B A G A [mm] Model A B C D E*1 Fn Fd G H J K XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27 12 40 26 44 21 XLC-
Auto switch type Symbol Nil M9N (L) M9P (L) M9B (L) A90 (L) A93 (L) M9// Symbol Nil H0 Temperature range 5 to 60C 5 to 150C Without auto switch (without built-in magnet) Remarks Auto switch D-M9N (L) D-M9P (L) D-M9B (L) D-A90 (L) D-A93 (L) Solid state switch 6. No. of auto switches/Detecting position Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.