Use the table as a guideline for mounting. MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Auto switches of D-M9N, D-M9P, D-M9B, and D-M9A are used. Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9NV, Lead
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9NV, Lead
Magnet: Built-in Magnet, Series: J2Z, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 100mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: Pivot Bracket shipped w/Product, Not Assembled, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: Built-in Magnet, Series: J2Y, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 30mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Single Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in
Magnet: Built-in, Mounting: Double Clevis, Bore: 16mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Rubber
Magnet: Built-in, Mounting: Rod Flange, Bore: 10mm, Stroke: 15mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Rod End Cap, Flat Type, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Series CJ2 is auto switch capable Non-rotating rod type, Bore sizes: 10 and 16 *, Strokes from 15mm through 200mm, Mounts: basic, root, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 0.076 lb
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.134 lb. 359.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.149 lb. 359.