SMC Corporation of America
Elite Part Number Search
Search Results "CDBG1BA63-500-HL-M9N-C"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, CBG1 END LOCK CYLINDER, PE, 63MM CBG1 DBL-ACT AUTO-SW, 4.9604 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, CBG1 END LOCK CYLINDER, PE, 63MM CBG1 DBL-ACT AUTO-SW, 5.88633 lb

M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.

1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721 30 250 -79No.PF-OMM0004-D / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -80No.PF-OMM0004-D PF3W704/720/740/711 A AA B D E F G H J K L N P PF3W704 3/8 70 50 30 60 40.6 15.2 24 14

COM C COM C is receiving data: Lights up COM C is having no data to receive: Goes off COM D COM D is receiving data: Lights up COM D is having no data to receive: Goes off : It is lit when input unit is connected and communicating normally. 19 18 Display/ Switch Setting (continued) Switch setting Make sure that switch setting is performed with power supply turned off.

Flow Characteristics Type 21P Flow characteristics Port size 14/2 (PA/B) 4/25/3 (A/BR) Effective area (mm2) C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(P), 5/3(R) port 2(B), 4(A) port Manifold Body ported for internal pilot SS5YJ3-21P SYJ323 1/8 M3 x 0.5 0.9 SS5YJ3-32P-M5 SS5YJ3-32P-C4 Base mounted for internal pilot 0.25 0.25 0.19 0.18 0.060 0.059 0.32 0.3 0.25 0.27 0.077 0.075 M5 x 0.8

Maintenance Caution Model Connection (Flange) 2B 8B C 2B/3B/4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 X l 400 Anchor bolt M20 X l 500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 q It is not possible to indicate a definite replacement interval for the element because it varies with the odor concentration of the compressed air.

Fittings & Tubing Air Cylinders Rotary Actuators BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch a e White (PBT) b Switch holder d Auto switch mounting screw c Auto switch mounting band Band

Calculation example: CS1L160-500 Basic weight27.57 (Foot style, 160) Additional weight2.39/100 stroke Cylinder stroke500 stroke 27.57 + 2.39 X 500/100 = 39.52kg Weight/Steel tubing (kg) Bore size (mm) 125 140 160 180 200 250 300 Basic 15.20 18.38 25.24 34.16 42.66 79.78 115.94 Foot 16.83 20.90 28.04 38.36 47.54 89.28 133.22 Front flange 17.88 23.38 31.63 43.99 54.57 101.62 146.14 Rear

Flow Characteristics Series Flow characteristics C [dm3/(sbar)] b Cv 0.089 0.32 0.72 0.31 0.41 0.38 0.36 1.2 2.7 SYJ300 SYJ500 SYJ700 Cover (stainless steel) Rubber Seal 3 Port Solenoid Valve Series SYJ300/500/700 Variations Option Series Port size Sonic conductance C [dm3/(sbar)] Manual override Type of actuation Voltage Electrical entry With light/surge voltage suppressor SYJ300 Effective

D D C CHK H B B H Material: Carbon steel Material: Carbon steel CHN Part no. d H B C D Applicable bore size (mm) NT-02 NT-03 NT-04 AC-NI-50 Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 CHM CHM 8 8 9 11 5 6 8 10 12.5 16.5 21.0 23 20 25 32 40 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 26 32 38 41 30 36.9 43.9 47.3 15.0 19.6 25.4 27.7 20 25 32 40 M22 x 1.5 M24 x 1.5 M30

M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

N.O. 4 position dual 3 port valve (C) (A) 4 (B) 2 3 (R2) 5 (R1) 1 (P) N.C.

Port R Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Air (Standard) Oil (Standard) (V) Port P Port A Maximum Minimum 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V in parentheses is option symbol. Option Material No.

REA Front trunnion: U Rear trunnion: T 32 42 48 52 0.3 Clevis: C, D C 22 30 35 37 0.5 REC Graph w Applicable max. stroke against lateral load* D 17 24 27 29 0.7 RHC W W W 500 82 103 116 127 0.3 Bushing (Bearing) MTS fR 62 79 89 97 U 0.5 Lateral load applied to rod end (fR) N 100 52 66 75 81 0.7 CC 50 33 43 49 53 0.3 10 23 31 36 39 0.5 T 5 18 25 29 31 0.7 Rear flange: G Front flange: F 182

3 Spring pin Roller pin Lever pin Ring A Ring B Adjustment dial End rod Lever spring Magnet Flat washer Flat washer C retaining ring for rod C retaining ring for rod C retaining ring for rod Return spring !4 !5 !6 !7 !8 !

Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 Thread type 1 2 10 20 Rc G NPT Nil F N Material Brass Stainless steel C S Type 30 OUT port size Stations VVCW20-4A Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 Type 10 is M5 only.

36 11 11 3 x M3 x 0.5 thread depth 6 10 25 25 P.C.D.29 Finger closing port Finger opening port M3 x 0.5 M3 x 0.5 M3 x 0.5 Finger closing port (Mounting thread) M3 x 0.5 Finger opening port 35.5 12h9-0.043 0 1.5 41.5 +0.02 0 3 x 3 depth 6 (A, B, C common view) 5 19.5 12 27 (45) 9 17 8 M3 x 0.5 thread depth 4 Vacuum suction port 2 2 6 x M3 x 0.5 thread depth 6 (A, B, C common view) -0 -0.05