~ ( 0 '" co; Port size 1/8' 1/4 Gauge '" U'" ~N Drain 45 40 M5 X O .8 With differential pressure type auto drain Optional Specification yJ Metal bowl 45 IN-OUT reversal mounting (-R) specification 9 Filter I Regulator Series AW it (mm) AW3001 .
Bracket assembly n pcs. (2) When regulators, end plate assembly and bracket assembly are assembled to make the manifold of n stations. Regulator n pcs. Bracket assembly n pcs.
Air Cylinder/End Lock Series MBB 32, 40, 50, 63, 80, 100 How to Order MBB L 32 50 H N Standard H N L 32 50 A53 MDBB With auto switch Number of auto switches Built-in magnet S 3 n 2 1 3 n Mounting Manual release Basic/Without bracket Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion B L F G C D T Bore size N L Non-locking Locking 32 40 50 63 80 100 Without auto
Stop 5 Series REA Sine Rodless Cylinder Dimensions (mm) REA 25, 32, 40 1in = 25.4mm Effective thread depth J L 0 0.1 NN G 4-MM H G B 2Port size I X D NB NB T N K W N S + Stroke F NA F R ZZ + Stroke MM x J B D F G H I K L N NA NB NN Model Port size REA25 REA32 REA40 Rc(PT) 1/8 46 27.8 13 8 20.5 34 10 70 M5 x 0.8 x 8 15 30 13 M26 x 1.5 Rc(PT) 1/8 60 35 16 9 22 40 15 80 M6 x 1.0 x 8 17 36 15
Example) Boll M5 x 65L frzr,r 4 bolts Diagram 1 D agram 2 Lever (with shock absober) Roller/round bar/non-rotaling Mounling bolt 50 40 30 25 20 15 ' 2 0 E 6 6 B r n 10 5 1 0 2 0 Load speed v (m/m n) Lateral load and operating pressure at Flush piping thoroughly beiore connection in orderlo preventdustorchipsf rom entedng the cylinder. Do not mark or damage lhe piston rod.
PE TB ILS ILS OLR PTC OLR PTC CM CM C02 C01 C11 FM C11 PRS FM PRS P MOV P MOV CM PTC PTC C01 FM PRS C02 OLR PC C11 ILS TB MOV 11 2 12.R R 12 12.1 12.2 1 AC100V AC200V INOUT IDF15E1-10-R IDF15E1-20-R (A) 10 (mA) 30 12.3 M5 9.5mm 1.25mm 2 L ,N N L () () 12 1 12.R AC100V M4 () AC200V (M3) 12.4 () () ONOFF 12 2 12.R 12.5 IDF15E1-10-R IDF15E1-20-R N L N L GFCI GFCI
9.5mm 2 1.25mm L ,N N L () () IDU Series 11-1 11 1 IDX-OM-W014 11 R AC100V M4 () AC200V, AC230V (M3) 11-4 () () ONOFF 11-5 1-1 IDU Series 11-4 11 2 IDX-OM-W014 12.S 12 S IDU3E/4E/6E-10 12-1 IDU Series 12-1 12-1 IDX-OM-W014 12.S 12-2 L N PE M3 6.5mm 2 1.25mm 12-3 1-1 IDU Series 12-2 12-2 IDX-OM-W014 13 T 13 T 13-1 IEC 13-2 AC200V / 2A DC24V / 2A ( 20V / 5mA)
pcs. + 3.5 x (n pcs. 1) 24 or more 31 0 0.4 4 x R2 or less Panel mount example
S n Thread type Nil Rc1/4 NPT1/4 G1/4 TN TF Bore size Made to Order MK 40 50 63 40 mm 50 mm 63 mm Refer to page 422 for details.
NPT1) Tank port size Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) Supply side pressure range MPa 0.2 to 0.5 Automatic water fill function (Standard) Supply side water temp. range oC 5 to 35 Automatic water fill port size Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2) Over flow port size Rc1 (Symbol F: G1, Symbol N: NPT1) Fluid contact part material Metal Stainless steel, Copper (Brazing filler metal
1) N NPN P PNP (1) 3 Assy ZQ1-PL11-A 4 Assy ZQ1-FC1-A 5 (10 ) ZQ1-FE2-A 6 ZQ1-CV 7 V VVQ1000-50A-C4 (1) 50A-M5 (M5x0.8) (1) 50A-C3 3.2 () 50A-C4 4 () 8 (10 ) 50A-C6 6 () ZK1-CP-A F1-LC3 3.2 () F1-LC4 4 () 9 Assy ZQ1-BK1-A 25 - No.ZQ-OM01401-B 7.3 b a a a 1. (2 ) 2.
FKM (Standard seal material) Principle materials Pilot pressure (MPa)(G) 0.3 to 0.6 0.4 to 0.6 Pilot port size M5 Rc 1/8 XMC 6.30 0.62 1.40 (1.76) 2.10 3.80 (5.16) 0.36 (0.40) Weight (kg) Note 2) XYC 7.80 0.67 1.42 2.50 4.50 Note 1) Conductance is the value for the molecular flow of an elbow having the same dimensions.
JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.
The tensile strength of the cord is 20 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor do not dangle it from the cord. 3. Do not exceed the screw-in torque of 3.5 Nm when installing piping. Exceeding this value may cause malfunctioning of the sensor. 4. The minimum bending radius of the cable is 50 mm. 5.
The tensile strength of the power cord is 49 N, and pulling it with a greater force can cause failure. 3. When handling the product, never move or loosen the switch assembly or the switch assembly mounting screws.
Tubing T S Coupler KK S Coupler/Stainless Steel (Stainless Steel 304) KKA Series T TU TH Material Nylon Polyurethane FEP (Fluoropolymer) Modified PTFE (Soft fluoropolymer) Super PFA PFA Metal One-touch Fittings KQB2 Stainless Steel 316 One-touch Fittings KQG2 TD TL TLM Stainless Steel 316 Insert Fittings KFG2 Fluoropolymer Fittings LQ 135 C O N T E N T S HRSH090 Series Inverter Type HRS
Confirm that the external force is 20 [N] or less. (The external force is the resistance due to cable duct, flexible trunking or air tubing.)
Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.
Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. 12. Output operation of the solid state auto switch is not stable for 50 [ms] after powered ON.
For encoder connector Screw size: M2 Tightening torque: 0.1 N m For brake connector Screw size: M2 Tightening torque: 0.2 N m For power supply connector Screw size: M2 Tightening torque: 0.2 N m -16- 4.4 Handling Warning 1. Do not touch the motor during operation. The surface temperature of the motor can increase to approx. 80C due to operating conditions.