._3d_items_collection = {}; } SMC AC00530 mounting screw, (GT CODES)CYLINDER HARDWARE*** $0.17 + Add to Quote Add To Cart Add to Cart SMC KQ2P-06 fitting, plug, KQ2 FITTING (
No.SYJ300-OMU0003
SYJ Series
Screw size: Cross recessed round head screw(M6 1 8 ) Screw color: Black KBE1-06, KBE2-06 KBE2-08, KBE3-08 KBE2-10, KBE3-10 KBE3-12, KBE4-12 87 Series M Miniature Fittings M3, R(PT) 1/8, M5 Hose nipple Barb fitting Tube Accepts nylon, soft nylon and polyurethane tubing. Barb Barb Easy tube insertion. High retaining force. Tube Easy tube insertion. High retaining force.
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
Refer to back page 50 for Safety Instructions and pages 543 to 546 for Flow Control Equipment Precautions. 603 AS Series How to Order 2 2 0 01 06 W2 AS 1F Body size 2 1 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 3 4 Metric size Applicable tubing O.D.
ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 04 06 08 10 12 4 6 8 10 12 Made to Order Refer to page 612 for details.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
No.PF-OMP0001CN-F // PFMB7501 PFMB7102 PFMB7202 2 10 11 12 14 14 16 17 [] 21 OU1OUT2 {3 ] 22 22 [] 24 25 F0 26 F1 OUT1 28 F2 OUT2 36 F3 41 F10 42 F13 43 F20 44 F22 45 F30 46 F31 47 F80 OFF 48 F81 49 F90 50 F98 52 F99 53 54 58 59 61 62 62 65 67 -1No.PF-OMP0001CN-F (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems
3/4 B(19.1) 25A 411 600-10 1 B(25.4) 2 32A 511 800-12 1 1/4 B(31.8) VNA01 VNA02 VNA03 VNA1 40A 611 900-14 1 1/2 B(38.1) (P1) () 12 50A 711 900-20 2 B(50.8) (P2) () 10 (),12(P1) 10(P2) EXH , 6 VN-OMP0002 1 2 3 () 4 P2 5 6 7 8 9 10 11 O O 12 13 14 7 VN-OMP0002 No. 1 2 3 4 5 , 6 7 8 9 10 11 P2N.C.
Connector and pin layout . 11 3-7. Center of gravity .12 4Product Specifications .13 4-1. Air gripper .13 4-2. 3-port solenoid valve .14 4-3. Auto switch .15 5. Operating method or operation .16 5-1Precautions for Design .16 5-2. Installation .16 5-3. CRX Plug-in software .20 5-4. Air supply .28 5-5. Piping .28 5-6. Operating environment .29 5-7. Lubrication .29 6.
The lubrication grease for O-ring and gasket is changed to white vaseline. 11 Main Line Filter Series AFF How to Order AFF37B/75B AFF 37B 10 Body size Made to Order (How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.)
Wiring 1) Pass them through the cable (7) in the order of cable ground (4), washer (5), rubber seal (6), and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). rubber seal (6), housing (2) in this order, and then connect with the terminal block (3).
Chamfering causes a narrower detection distance range. 1.0 ~ 2.0mm H O W T O O R D E R A I R C AT C H S E N S O R S E R I E S ISA Min 2.0mm ACCESSORIES A I R C AT C H S E N S O R S E R I E S ISA Bracket ISA-1-A Gauge G33-3-01 ISA 01 O U T P U T 11 NPN 15 PNP Min 3.0mm N O.
Refer to pages 16-143 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Common B (N.C.) A White Normally Open B Red Normally Closed Mounting & Wiring ZSE ISE IFW50--01 to 04/11 to 14/21 to 24 Caution PSE 1.
3 times for each direction) Impact resistance High pressure High vacuum 5 g (Excluding lead wire) Weight 6 reducer Port size IP40 Enclosure Grommet oil-proof cabtire cord 2-wires 2.55, 0.18 mm2, 3 m Lead wire Pressure setting trimmer Caution Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 6 8 10 12 Inch sizes 03 05 07 11 13 1/8 3/16 1/4 3/8 1/2 Different diameter tubing order example Basic size With reducer Note) Applicable fitting: LQ2 Different diameter tubing (with plug-in reducer) can be selected within the same body class. (Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below.
Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.
OUT(2) 1 Thread type Rc NPT G Nil N F IN(1) Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Port size Class 3 Port size 1/8 (6A) 1/4 (8A) Class 2 Class 4 Symbol 01 02 03 04 06 3/8 (10A) 1/2 (15A) Class B in AC has a rectifying circuit built-in. Class H is AC only. No rectifying circuit.
Thread type Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Voltage Port size 1/8 (6A) Class 3 Class 2 Class 4 Symbol 01 02 03 04 06 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Please consult with SMC regarding other voltages.
R6teren@ torque sDecificalion Tabl *3 '11 lflU / [[U $enies D0I/$[EfirHu Union 'Y': KVU*_ OO l02C / lffi / lflP $mics D0I/8[EthHt Caps: KQ2C Fitting Boot: KR 6D r-'---t-1 Plugs: KVP 1 2 D0r/$uffnFll|lnm tul $enie Cartridge: KVOA DOT Specilications Tabl 1 Not alaihu at lim6 of cablog prinling, Corbult hdory br a\bilability.