For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 4 Paddle Style Flow Switch
28 22.5 M5 x 0.8 30 30 54.4 56 11 67 28.5 13 4 20 44 7 23 31.5 17 M5 x 0.8 6 35 35 79.5 62 17.5 83 45.5 14.5 6 22 50 7 37 6 36 21 M5 x 0.8 35 35 82 62 20 93 48 14.5 6 22 50 7 39 6 36 21 M5 x 0.8 45 45 105.5 76 25 114 65 17.5 8 32 64 7 52 6 38.5 25 M5 x 0.8 17-5-48 7 Series LVD Integral Fitting Type (Hyper Fittings) With flow rate adjustment (Max.
2 3 4 5 n U side VDW23-GVDW23-GVDW23-GVDW23-G70 31.5 21 18.5 (OUT port) n-1/8 n-M5 x 0.8 11 P = 22 11 4.5 1.5 54 6 32 6 (19.5) 9.5 11 9.5 11 4-M4 x 0.7 46 10 24 10 When w/o bracket, M3 threads at both ends (4 positions) can be used for other purposes.
P.7 Manifold Dimensions (DIN Connector Type) P.8 Manifold Dimensions (Prewired Connector Type) Manifold Options P.9 to 12 Manifold with Control Unit P.13, 14 Option Dimensions P.15, 16 Series VQ7-8: Single Unit How to Order Valves P.17 Models, Standard Specifications P.18 P.19 Single Unit Valve Dimensions (DIN Connector Type) P.20 Single Unit Valve Dimensions (Prewired Connector Type) P.21
11 Hexagon width across flats 21 11 Width across flats 37 4-M4 x 0.7 45 Width across flats 24 3-M3 x 0.5 28 H H 10 10 G G F F E E Y Y 3 4 18 34 C C A A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B D B D Dimensions Dimensions (mm) (mm) A B C D E G H I Y A B C
t41x1.5 M 1 8 X 1 . 5 M 1 8 X l . 5 M22X1.5 t\r26x1.5 27 v4 42 20 45 1 5 3 8 60 I 80 42 100 2t5 52 43 59 v. 30 ls 46 1 0 21 50 168 0 70 I 90 50 1 1 0 58 237 58 52 1 5 66 n 6 ?
-r a Stations fUfiotlo ihl drb rsft vJ3000-21-1A End cover srde of --Frqclsaqq!
-r a Stations fUfiotlo ihl drb rsft vJ3000-21-1A End cover srde of --Frqclsaqq!
7661 Table of Contents Section I 1-9 Valves 1-2 Understanding Circuit Symbols 3 Cv Defined 4 Pneumatic Valve Sizing 5 Valve Selection Guide 6-9 Frequently Asked Questions Section II 10-19 Cylinders 10 Size Selection 11 Piston Rod Strength 12 Pneumatic Cylinder Force 13 Air Cylinder Speed 14 Air Consumption Rates 15-19 Frequently Asked Questions Section III 20-24 Circuits 20 Basic Control 21
21 2 x 3.4 (Through holes for mounting) 47.4 (2) 15 2 x M5 x 0.8 (Pilot port) 37.8 + Stroke 39.5 + Stroke 36.3 29.7 + Stroke 4 9 2 15 30 20.7 + Stroke 17.4 30 (49.4) 4 x M3 x 0.5 depth 2.5 21 8 +0.1 9 0 depth 2.5 21 Auto switch MXZ20R(Pilot port location: Right) MXZ20L(Pilot port location: Left) 2 x M5 x 0.8 (Pilot port) 2 x M5 x 0.8 (Pilot port) 20.7 + Stroke 20.7 + Stroke 9 9 (47.4) (47.4
M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable
.: 6, 1/4" (With check valve) (External pilot port) (M12 connector) 2 x 1/2" [3(R) port] 67 6.5 Applicable cable O.D. 3.5 to 7 2 x 6.2 (For mounting) G1/2 Channel 2 113.5 41.5 36 94.5 77.5 Channel 1 36 21 9.5 (88.9) 16 18 (14) (Max. 10) 224.2 117.3 27.2 (70.7) A 124.8 99 View A For M12 connector 36 18 e w Vent port (6.2) 1/2" [1(P) port] 40 r Pin number (22.9) (With check valve) q 88.9 80
Note 9) If the product is used at altitude of 3280ft (1000 m) or higher, refer to Operating Environment/Storage Environment (page 21) Item 13 For altitude of 3280 ft (1000 m) or higher. Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less.
7661 Table of Contents Section I 1-9 Valves 1-2 Understanding Circuit Symbols 3 Cv Defined 4 Pneumatic Valve Sizing 5 Valve Selection Guide 6-9 Frequently Asked Questions Section II 10-19 Cylinders 10 Size Selection 11 Piston Rod Strength 12 Pneumatic Cylinder Force 13 Air Cylinder Speed 14 Air Consumption Rates 15-19 Frequently Asked Questions Section III 20-24 Circuits 20 Basic Control 21
model 1027 VBAT Series CE Marking-Conformity Products Specifications Model VBAT05A-SV-Q VBAT10A-SV-Q VBAT20A-RV-Q VBAT38A-RV-Q Fluid Tank capacity (L) Max. operating pressure (MPa) IN port size OUT port size Ambient and fluid temperature (C) Installation Weight (kg) Material Paint Compressed air 10 20 38 5 2.0 1.0 3/8 1/2 3/4 3/8 1/2 1/2 3/4 0 to 75 Horizontal (Floor mounting) 6.6 10 14 21
Rz 3.2 or less for sheet surface 500 Compact / Lightweight 2 Port Solenoid Valve VDW30/40-XF Series For Air/Water Dimensions VDW30-G--C4 C6 /One-touch fitting for 4, 6 VDW40-G-/One-touch fitting for 8, 10 C8 C10 36 30 21 23 Approx. 300 32 17.5 20 Approx. 300 27 56 48 10 9 18 21 3 3 21 23 26 A A C4, C6 1 (IN) port C4, C6 2 (OUT) port C8, C10 1 (IN) port C8, C10 2 (OUT) port Dimentions A 3
VQ1170 N 5MO C6 L dimension 21 22 23 24 25 26 27 28 29 30 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 No. L dimension 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.
Fittings & Tubing Air Cylinders Rotary Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting
Fittings & Tubing Air Cylinders Rotary Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting
LECP6 LECP1 (Programless type) PController Supplied by customer Controller power supply 24 VDC Step data input type LECP6 Programless type LECP1 Page 13 Page 24 P Power supply connection Pages 16, 30 Connection Controller type LECP6 (Step data input type) Power supply plug (accessory) Power supply cable (1.5 m) (accessory) LECP1 (Programless type) P Controller setting kit (Option) Page 21