Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07 to 1, Specification: Built-in magnet, Body Options: Standard (rod-end female thread), Auto Switches: M9P
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -, End Locking: No, Valves
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -, End Locking: No, Valves:
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 42, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 42, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 42, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Chuck Type / Open, Chuck Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20, Closed Dimension L2(mm): -, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape (Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 141, Gripping Force (Open Side at 0.5 Mpa)(N): 141, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Chuck Type / Open, Chuck Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20, Closed Dimension L2(mm): -, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape (Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 141, Gripping Force (Open Side at 0.5 Mpa)(N): 141, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Chuck Type / Open, Chuck Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20, Closed Dimension L2(mm): -, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape (Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 141, Gripping Force (Open Side at 0.5 Mpa)(N): 141, Environment, Applications: Standard, Additional Function: With Linear
(Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 141, Gripping Force (Open Side at 0.5 Mpa)(N): 141, Environment, Applications: Standard, Additional Function: With Linear Guide / Stroke Adjustment Function, Stroke Adjustment Mechanism: Open/Close Dual Adjustment, Operating Pressure Range(MPa): 0.1~0.7, Cylinder internal diameter(mm): 20, Body options: Axial piping, Auto switch: M9P
How Grip: Pinch, Chuck Type / Open, Chuck Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20, Closed Dimension L2(mm): -, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape (Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 141, Gripping Force (Open Side at 0.5 Mpa)(N): 141, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 34.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 42, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 34.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 42, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Related Components] AHC Air Chuck, Operation Method: Single Acting Type (Normally Closed), Main Body Shape: Square Shape, Gripping Force (Open Side at 0.5 Mpa)(N): 68, Environment, Applications: Standard, Additional Function: Not Provided, Stroke Adjustment Mechanism
How Grip: Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Related Components] AHC Air Chuck, Operation Method: Single Acting Type (Normally Closed), Main Body Shape: Square Shape, Gripping Force (Open Side at 0.5 Mpa)(N): 68, Environment, Applications: Standard, Additional Function: Not Provided, Stroke Adjustment Mechanism
Magnet: Built-in, Mounting: Front Flange, Bore Size: 20mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 20mm, Body Option: Standard, Locking Direction: Retracting Stroke Lock, Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Foot, Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 20mm, Body Option: Standard, Locking Direction: Retracting Stroke Lock, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -