One-Touch mini fittings series KJ is available for use with SMC miniature valves and actuators, M3 and M5 ported. Their compact one-touch collet design allows easy disassembly with strong tube gripping. Electroless nickel plating is standard. KJ fittings are available to order in multiples of 10.The current KJ series fitting has been discontinued.
One-Touch mini fittings series KJ is available for use with SMC miniature valves and actuators, M3 and M5 ported. Their compact one-touch collet design allows easy disassembly with strong tube gripping. Electroless nickel plating is standard. KJ fittings are available to order in multiples of 10.The current KJ series fitting has been discontinued.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, AS 1/2INCH STANDARD (PT), AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), 0.0263 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, EXTERIOR SEAL FOR XLA, VACUUM SERIES, XLS NO SIZE RATING, .05557 lb
One-Touch mini fittings series KJ is available for use with SMC miniature valves and actuators, M3 and M5 ported. Their compact one-touch collet design allows easy disassembly with strong tube gripping. Electroless nickel plating is standard. KJ fittings are available to order in multiples of 10.The current KJ series fitting has been discontinued.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, SLOW START, AIRLINE EQUIPMENT, ASS 3/8INCH EUROPEAN, .48840 lb
One-Touch mini fittings series KJ is available for use with SMC miniature valves and actuators, M3 and M5 ported. Their compact one-touch collet design allows easy disassembly with strong tube gripping. Electroless nickel plating is standard. KJ fittings are available to order in multiples of 10.The current KJ series fitting has been discontinued.
Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, I7, AS 1 1/4INCH EUROPEAN, 3.52739 lb
One-Touch mini fittings series KJ is available for use with SMC miniature valves and actuators, M3 and M5 ported. Their compact one-touch collet design allows easy disassembly with strong tube gripping. Electroless nickel plating is standard. KJ fittings are available to order in multiples of 10.The current KJ series fitting has been discontinued.
m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard450.44
Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.
M3 hexagon screw Tightening torque: 0.6 Nm Tie-rod Tightening torque: 0.6 Nm PWR Green Light Illuminates when power for CANopen line is supplied. Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Illuminates when SI unit is in the Operational state.
SW1 Input block connector ON 1 Communication connector 0 M3 ground terminal Power supply connector Display Description 1 2 3 4 5 6 7 8 OFF Insufficient power supply for solenoids To obtain the operation manual about this product, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly.
(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. EtherNet/IPTM communication is not established. Green flashing 4 EtherNet/IPTM communication is established. Green ON NS EtherNet/IPTM communication is time-out. Red flashing Valve plate (EX600-ZMV ) IP address is duplicated. Red ON Safety Instructions (5)Connect the SI unit to the valve manifold.
(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Link, No Activity (100 Mbps) Link, Activity (100 Mbps) Link, No Activity (10 Mbps) Link, Activity (10 Mbps) L/A PORT2 Valve plate (EX600-ZMV#) Refer to the SMC website (URL https://www.smcworld.com) for more information about LED state. Safety Instructions (5)Connect the SI unit to the valve manifold.
(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. Single Flash Safe operational status (Green) ON Operational status 4 OFF No communication error Flash Communication setup error Valve plate (EX600-ZMV ) (Red) Double Flash Communication error (application watchdog timeout) Safety Instructions (5)Connect the SI unit to the valve manifold.
(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Valve plate (EX600-ZMV ) Safety Instructions (5)Connect the SI unit to the valve manifold. Insert the valve plate into the valve plate mounting groove on the side of the SI unit.
(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 LED Display 300 g Weight Refer to the product catalogue or SMC website (URL https://www.smcworld.com) for more information about product specifications. Valve plate (EX600-ZMV#) The status display LED displays the power supply and communication status. Safety Instructions (5)Connect the SI unit to the valve manifold.
M3 hexagon screw Tightening torque: 0.6 Nm Tie-rod Tightening torque: 0.6 Nm If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.