SMC Corporation of America
Elite Part Number Search
Search Results "SS5Q13-02PDC-D-00T"

Output specifications Symbol OUT1 OUT2 A NPN NPN B PNP PNP C NPN Analog (1 to 5 V) D NPN Analog (4 to 20 mA) E Note 2) PNP Analog (1 to 5 V) F Note 2) PNP Analog (4 to 20 mA) G Note 2) NPN External input Note 3) Unit specifications Nil Unit selection function Note 5) M SI unit only Note 6) Note 5) Since the unit for Japan is fixed to SI due to new measurement law, this option is for overseas

D Auto identification function Display units can be selected using either or . This function automatically identifies the pressure range of the pressure sensor that is connected to the multi-channel pressure sensor controller, thus eliminating the need of having to reset the range again after replacing the sensor.

Series HRS100/150 CAT.NAS40-62B R410A as refrigerant Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller Triple controller Fan Air-cooled condenser fan control Cooling valve Heating valve Circuit diagram Ventilation Cooling valve control Fan Facility water outlet Temperature sensor (Heat exchanger inlet) Water-cooled condenser Dryer Air-cooled condenser D

8 F 24 VDC 5 G DIN terminal 24 VDC With surge voltage suppressor A B D E H J L M 4 H 100 VAC Size 2 2 1/4 N.C. 7 J 110 VAC Aluminum 4 5 N.O. 3/8 K 200 VAC 7 L 230 VAC 4 8 7 Resin (With bracket) M Conduit terminal 24 VDC With surge voltage suppressor 4 N 100 VAC 10 7 P 110 VAC A B C D E F G H J K L M N 5 Q 200 VAC Size 3 3 N.C. 8 1/4 R 230 VAC 10 (N.C. only) 6 N.O.

CEP1 Action D B T CE1 CE2 Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.

D-A9, M9, M9W, M9A auto switches are shipped together (not assembled).

Compact Hydraulic Cylinder Double Acting/Single Rod CHQB Series 20, 32, 40, 50, 63, 80, 100 3.5 MPa How to Order CHQB 50 30 D CHDQB 50 30 M9BW D With Auto Switch With auto switch (built-in magnet) Made to order specifications For details, refer to page 243.

Nil S n No Perpendicular to axis D With auto switch (Built-in magnet) Nil For a cylinder with D, -B is suffixed to the end of the part number. Auto switch Axial R Nil Without auto switch For applicable auto switches, refer to the Applicable Auto Switch.

The D-M9M and M9VM type (lead wire length: 1 m) will be available with products delivered from August 2008 onwards. The water resistant improved D-M9A and M9AV type can be mounted, but cylinders are not designed to be water resistant improved construction.

D-sub connector (25 pins) Note1) 2) Spring type terminal block (32 pins) Note1) 2) DM EX600 Digital Input/Output Unit Input/Output type Number of inputs/outputs and connector Description PNP NPN Number of inputs 8 inputs 8 inputs Number of outputs 8 outputs 8 outputs Symbol Connector Symbol P N E F D-sub connector (25 pins) Note1) 2) Spring type terminal block (32 pins) Note1) 2) Note 1)

CJ2-Z Series Air Cylinder/10, 16 10-/1121-/22How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Rubber bumper (Standard) Air cushion Nil A 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location 2 pcs. 1 pc. n pcs.

Note Weight Bracket LFE-1-D Tapping screw for LFE1 (3 x 10), 4 pcs. Approx. 45 g LFE-2-D Tapping screw for LFE2 (3 x 10), 4 pcs. Approx. 70 g LFE-3-D Tapping screw for LFE3 (3 x 10), 4 pcs. Approx. 70 g 3

D-LC05: Lead wire 0.5 m D-LC30: Lead wire 3 m D-LC50: Lead wire 5 m Rotation adjustment range Single vane: Both ends 5 each Vane type Auto switch S Single vane Nil Refer to the table below for the applicable auto switch model. Without auto switch (built-in magnet) Applicable Auto Switch/Refer to pages 761 to 809 for further information on auto swiches.

Note Data 16 CJ-L016B CJ-F016B CJ-T016B T-bracket is used with double clevis (D). 1. For Series CJ2X, 0.1 Nl/min is the values at maximum in terms of its construction and there is internal leakage (ANR). Foot bracket Flange bracket T-bracket BJ2-010 Common for the types of D-C7/C8 and D-H7 BJ2-016 10-3-7

How to Order VFN212 02 N 5 F D Z CE marking NAMUR Interface Nil Q CE marked product Voltage Thread type 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz Nil Rc (PT) F G (PF) N NPT Electrical entry Solenoid G Grommet E Grommet terminal T Conduit terminal D DIN terminal Nil Single solenoid D Double solenoid Manual