Please consult with SMC representative for accurate lead times*** Orifice diameters: ø4, ø8, ø10, ø16, ø22; Flow characteristics: 0.35 to 8 Cv; Operating pressure: 0.3 to 0.5 MPa; Fluid temperature: 0 to 100° C; Ambient temperature: 0 to 60° C; Tubing O.D.: Metric size – 6, 10, 12, 19, 25; Inch size – 1/4", 3/8", 1/2", 3/4", 1"

Cooling capacity: 140 W, 320 W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 100 ~ 240 VAC, 50/60Hz ; Circulating fluid: Clear water or 20% ethylene glycol ; Standards: CE, UL, RoHS

PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100, 50-250; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 (flow range dependent); Temperature rating: 0-90°C; Output options: 1-5V or 4-20mA; Accuracy: ±3% F.S. ; Repeatability: ±2% F.S.

PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 10-100, 30-250; Port sizes: 25A (32mm) or 30A (38mm) (flow range dependent); Temperature rating: 0-70°C; Output options: 1-5V, 4-20mA; Accuracy: ±3% F.S. ; Repeatability: ±2% F.S.

PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100, 50-250; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 (flow range dependent); Temperature rating: 0-90°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.

PF3W is grease-free, IP65 rated, and C-UL-US, CE and RoHS compliant. Flow ranges (lpm): 10-100, 30-250; Port sizes: 25A (32mm) or 30A (38mm) (flow range dependent); Temperature rating: 0-70°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.

Cooling capacity: 230W, 600W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 100 ~ 240 VAC, 50/60Hz ; Circulating fluid: Clear water ; Standards: CE, UL, RoHS

Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 100 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution

Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW, 2.2 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 200 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution

Angle seat structure to minimize pressure loss; 316L stainless steel equivalent material, port sizes: 3/8" to 2"; Optimized flow channel for large flow capability; Easy maintenance; Built-in visual indicator; Fluid temperature: Steam: 183°C or less, Water/Air: 99°C or less

Cooling capacity: 150W; Heating capacity: 380W; Dimensions: 140mm x 160mm x 240mm; Temperature range setting: 4 to 60°C; Temperature stability: ±0.03°C or better depending on load stability; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE/UKCA, UL, RoHS

For high-pressure washing, water spraying, and misting; An IP67 structure with improved environmental resistance; Orifice diameter (mm): 12; Fluid temperature: 1-60°C, ambient -20 to 60°C; Flow rate characteristics (CV): 2.0 (Port size 3/8), 2.2 (Port size 1/2); Easy maintenance, coil can be replaced by simply removing the clip; Available with M12 connection

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.

Magnetically coupled rodless cylinder; Direct mount type; Compatible with secondary battery manufacturing; Bore sizes (mm): 15, 20, 25, 32, 40; Ambient temperature: -10 to 60°C; Auto switch capable

Air cylinder series 90-C(D)J2 miniature cylinders available in double acting and offer stainless steel tubing and stainless steel rods. 90-CJ2 is made from materials compatible with secondary battery manufacturing. 91-CJ2 includes a "Lub-retainer" and is compatible with low dew point (40°C) applications.

Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 100 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution

Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW, 2.2 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 200 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution

Cooling capacity: 230W, 600W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 100 ~ 240 VAC, 50/60Hz ; Circulating fluid: Clear water ; Standards: CE, UL, RoHS