SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20C-T-N02L-K"

Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K

Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K

Body Size: 3, Thread: Rc, Port Size: 03 (3/8), Handle/Bonnet Material: B (Aluminum), Options: None, Semi-Standard: K (Handle Color, Black)

.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K

Size: 15 [2.8m³/min (ANR), 98.88scfm], Version: 1 (Size 15 Only), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: K (Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure)

Symbol: 205R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material/Port Size: w/o Sub-plate, Lead Wire Length, Electrical Entry, Light/Surge Suppressor: K (Plug Connector, 300mm)

Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: N01 (NPT 1/8), Option: M (w/M5, Female Thread)

Data Note 16 CJ-L016B CJ-F016B CJ-T016B T-bracket is used with double clevis (D). 1. For Series CJ2X, 0.1 Nl/min is the values at maximum in terms of its construction and there is internal leakage (ANR).

Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89

When fluid is exhausted from the port 12(P1), the valve r connected with the piston t is closed by the return spring y. When valve opens When pressurized air enters through the port 12(P1), the valve piston moves upward by the pilot air that enters below the piston and the valve element opens.

7 t CRB2 Single vane For 180 (Indicates intermediate position) For 90 (Indicates A port pressurized) CRBU2 CRB1 @1 Component Parts MSU !1 u Material Description No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 !

.: FBK turbine 32, Diamond turbine oil 32 Maruzen: Turbine super 32 The {T Series W (white)} nylon tube can be used for hydraulic piping. Self-aligning fittings can be used for hydraulic piping, but one-touch fittings cannot be used. RB Make sure that there are no extreme differences in the bore of the pipes used for hydraulic piping. Also check for protrusions or burrs.

Data Note 16 CJ-L016B CJ-F016B CJ-T016B T-bracket is used with double clevis (D). 1. For Series CJ2X, 0.1 Nl/min is the values at maximum in terms of its construction and there is internal leakage (ANR).

9 t !8 i !0 @0 @0 y @1 !6 w q !9 t !8 !0 i Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !1 r !4 @2 u o !3 @4 e !5 !1 r u @2 @3 !3 @4 e !2 MXH16/20 (16, 20) @0 y @1 !7 w q!9 t !8 i !0 !1 r u @2 @3 !3 @4 e !

D M9N S A PC Application example Ordering example t Y connector IN574-95 1 pc. Cylinder Speed Checker (Sensor head + Display part) Applicable auto switch y Field wireable connector Connector model Function Electrical entry Applicable model D-M9N 2 pcs. Auto switch with lead wire entry PCA-1557730 2 pcs. Field wireable connector PCA-1557798 1 pc.

Smallest settable increment 1 0.01 0.1 5 C O N T E N T S ISA3 Series 3-Color Display Digital Gap Checker ISA3 Series How to Order (Without Control Unit)Page 7 How to Order (With Control Unit) Page 8 SpecificationsPage 9 Supply Pressure Dependence CharacteristicsPage 10 Response TimePage 11 Relationship between Displayed Value and DistancePage 12 Nozzle ShapePage 12 Internal Circuit and Wiring

KR KA KQG2 KG KFG2 MS KKA KP KP LQ MQR T IDK 361 KP/KPQ/KPG Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. Maintenance Operating Environment Warning Caution 1.

Description Material 1 Body Aluminum die-casted 2 (B) 4 (A) 2 Spool assembly Aluminum/FKM e 3 Plug (For the -X1) Steel 1 High Speed Pilot Operated Solenoid Valve DXT1215 Series How to Order Valves DXT1215 T 5 Wm U 01 N X1 w y e r t u q q Coil type w Rated voltage e Electrical entry M8 connector1 T With power-saving circuit 5 24 VDC Wm WO With straight connector cable Without connector cable