Bus cable specification Termination Bus length [m] Length-related resistance [m/m] Cross-section [mm2] resistance [] 040 <70 0.250.34 124 40300 <60 0.340.6 150300 300600 <40 0.50.6 150300 6001000 <26 0.750.8 150300 For drop cables, a wire cross-section of 0.25 to 0.34 mm2 would be an appropriate choice in many cases.
valve with lamp and circuit of protection of surge voltage of 24 VDC 1.5 W (SMC) Power supply (output) 24 VDC Class2, 2 A Output for com. error HOLD/CLEAR/Force ON Protective function Short circuit protection Enclosure IP67 (with manifold assembled) 1 Operating temperature range -10 to 50 oC (Max. surrounding air temperature rating: 50 oC) 2 Environment Storage temperature range -20 to 60
(between case and cable) Ambient temperature -10 to 60 C Enclosure IEC 60529 criteria IP67, JISC0920 watertight construction -23No.D-S-OMJ0004-G D-M9BW(V)/D-M9NW(V)/D-M9PW(V) PLC: Programmable Logic Controller Switch part no.
failure Problems 0x5111(20753) Decline in the power supply voltage Warning 0x8CA8(36008) Detectable magnetic field is decreased Warning -19No.D-S-OMU0002-A Product individual parameters Index Subindex Access 1 Parameter name Format Length Initial value DS Selection range (decimal number) 2 Value/Range SetPoint1 bit(16) 16 bit 3 Y 3 1 R/W 0x003C BDC1 2 R/W SetPoint2 bit(0) 16 bit 3 Y 3 (60
CEU5 has a power supply for encoder (12VDC, 60 mA). If an encoder requires a power other than 12VDC or large current consumption, use a separate power supply.
Item No Remarks Ethylene glycol aqueous solution 60% HRZ-BR001 Please dilute to 15% with tap water and use it.
(humidity) oC Inlet air pressure MPa 250 Indoor 1 phase 100VAC 1 phase 200VAC 1 phase 100VAC 3 phase 200VAC 3 phase 200VAC 3 phase 200VAC (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) 50Hz 55 58 55 50 90 204 60Hz 58 65 65 60 130 244 50Hz 0.8 0.43 0.8 0.4 0.4 2.0 60Hz 0.81 0.46 0.9 0.35 0.45 2.0 Power supply Electric specifications Power consumption Current 255 1.5 300 Proof
. -4- 1.1.2 Specification Model LEJS100T9H LEJS100T9A LEJS100T9B Stroke [mm] *1 200300400500600800100012001500 3000(mm/s2) 60 150 400 5000(mm/s2) 43 93 150 Horizontal 9800(mm/s2) 22 36 Work load [kg] *2 3000(mm/s2) 14 29 80 5000(mm/s2) 12 29 30 Vertical 9800(mm/s2) 8 9 Actuatr specifications Electric specifications Lock unit to 500 2300 1250 500 Max. speed *3 501 to 1000 1600 800 320 [mm/
If cylinder is getting hot, modify operating conditions such as frequency to keep the temperature below 60. Replace cylinder if switch still does not turn on with the measures above. 22 - 23 - Revision history Revision A: Addition of Caution for product with locking mechanism (P.12) Revision B: Seal kit number deletion(P.17,23) Wrapping of sealant tape is changed.
How to Order 30 K 03 BE AW D Symbol Description Body size 20 30 40 60 Nil Without backflow function With backflow function K With backflow function Nil Rc Thread type N NPT F G 01 1/8 02 1/4 03 3/8 1/2 Port size 04 06 3/4 10 1 Nil Without mounting option a Mounting B With bracket H With set nut (for panel mount) Nil Without auto drain Float type C N.C.
Standard Specifications Model AFM20-D AFM30-D AFM40-D AFM40-06-D Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 Air Fluid -5 to 60 C (with no freezing) Ambient and fluid temperature Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Min. operating 0.15 MPa N.C. 0.1 MPa pressure of auto 0.1 MPa N.O.
Cable color Signal name Conductor size(AWG) IZF10R-CP 3000 +60 0 1 Brown +24 VDC 26 +100 0 IZF10R-CPZ 9850 2 Blue 0V 26 3 Green F.G. 26 AC adapter 4 Yellow Maintenance signal 26 5 Purple Error signal 26 IZF10R-CG1 (With AC cord) F.G. cable (AWG26, semi-stripped terminal) AC adapter AC cord IZF10R-CG2 (Without AC cord) F.G. cable (AWG26, semi-stripped terminal) Inlet IEC60320-C8 AC adapter
Add 10 g for conduit type, 30g for DIN terminal type, 60 g for conduit terminal type respectively. Refer to Glossary of Terms on page 6 for detail of max. operating pressure differential and max. system pressure. 10 Select an option mark in page 7 by Applicable Fluids Check List for special fluids outside of the standard.
: 50 Auto-shift input Non-voltage input (reed or solid state), Low level 0.4 V or less, input time 5 ms or more Display 3 1/2digits, 7-segment, dual-colour display (red/green) Display accuracy 2% F.S. 1 digit (at ambient temperature 253 C) Indicator LED LED is ON when output is ON OUT1, OUT2: Orange Enclosure IP65 Environment Operating temp. range Operation: -5 to 50 C, Storage: -10 to 60
Specifications Fluid Air Note1) 1.5MPa(1.05MPa) Proof pressure Note1) 1.0MPa(0.7MPa) Max. operating pressure Note1) 0.05MPa(0.1MPa) Min. operating pressure Standard -5 to 60 deg.C (No freezing) Ambient and fluid temperature -H Note2) -5 to 80 deg.C (No freezing) -L Note3) -30 to 60 deg.C (No freezing) Note 1) ( ): Values for AS1000. Note 2) AS5000 is available as special.
Maintenance Air temperature() -20 -10 0 10 30 40 50 60 1. Perform maintenance inspection according to the procedures indicated in the operation manual. If handled improperly, malfunction and damage of machinery or equipment may occur. 2.
C Operation: -5 to 50 C Ambient temperature Storage: -10 to 60 C Environ ment (No condensation, No freezing) (No condensation, No freezing) Ambient humidity Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC, 1 min. 250 VAC, 1 min.
Models with auto switch 1.Keep the temperature of the switch below 60 oC. With heater (thermistor) 1. When using a model with a heater, a mechanism to prevent overheating should be installed 2.If using gases that generate a large amount of deposits, it is recommended that the valve body be heated to prevent deposits from sticking to the valve surfaces. Selection Caution All models 1.
TEMP READY is displayed on the operation display panel 60-sec. after TEMP PV value becomes 18C to start output by communication. Necessary condition is that TEMP PV value after 60sec. is 20+/-2.0C or less. See 5.3.4 Status screen 3on page 5-4 for the details of display position.
Monosashi-kun series CEU5 sensor input part +12V +12V White Blue COM +12V +12V Yellow Brown COM n Red +12V Built-in sensor power supply 12VDC, 60 mA Black Cable with shield .. Earth 4-3 Noise countermeasures Follow the instructions below to prevent malfunction due to noise. 1. Use SMC extension cable CE1-R** for wiring of MONOSASHI-KUN and CEU5. 2.