NARM2000 .18 1.36 1.69 1.10 1.06 2.76 .79 .45 .94 1.10 2.60 .45 .65 .19 (4.5) (34.5) (43) (28) (27) (70) (20) (11.5) (24) (28) (66) (11.5) (16.5) (4.8) Dimensions by number of stations Model Symbol A C E F G H J K M P NARM1000 L1 1.42 2.17 2.91 3.66 4.41 5.16 5.91 6.65 7.40 8.15 (36) (55) (74) (93) (112) (131) (150) (169) (188) (207) L2 1.06 1.81 2.56 3.31 4.06 4.80 5.55 6.30 7.05 7.80 (27) (46

Symbol 46 42.5 Outside diameter Indicator light Max. display pressure Symbol 10 1.0 Unit: MPa Without indicator light Nil L2 Neon light (100 VAC/220 VAC) Attachment (Cover ring assembly) L5 LED/24 VDC Connection thread Without cover ring assembly Symbol Specifications Symbol Size Nil 01 R 1 8 Clear cover has no protrusion. (Clear cover is irremovable.)

A L1 L2 M 1 8 4 L04-01 33 10 21.8 30.9 15 3.5 32.7 10 14 10 1 4 1 8 L04-02 L06-01 40 36 14 10 34.9 30.9 34.7 33.8 1 4 3 8 1 8 6 L06-02 L06-03 L08-01 43 55 46 14 17 12 34.9 36.9 31.9 16 9 21.8 35.8 37.5 36 12 10 14 1 4 3 8 1 4 8 L08-02 L08-03 L10-02 52 61 68 14 17 14 16 19 23.3 35.9 37.9 36.9 38 39.7 40.7 14 12 17 3 8 1 2 1 4 3 8 1 2 Reference dimensions after R(PT) thread installation. 10

D1 D2 L A M M5, M6 Nylon Urethane M5 0.8 M6 1.0 KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S 38.5 11 13 39 35 8 10.4 2.5 4.0 4.0 16 4 1 8 M5 0.8 M6 1.0 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 12 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 12.8 15 17 1 8 1 4 1 8 38 39 42 43 44 20 26 28 34 42 68

(variation on the order of 30%) Large variations may occur depending on the surrounding environment. 6, 10, 15, 20 (mm) Auto switch model A B D-M9 D-F9W C D-M9 D-F9W D D-M9 D-F9W D-M9 D-F9W Bore size (mm) D-A9 D-A9 D-A9 D-A9 6 10 15 20 30 32 21.5 23.5 42 44 72.5 83.5 42 44 35.5 30 32 60.5 71.5 26 28 17.5 19.5 46 48 76.5 87.5 46 48 39.5 26 56.5 67.5 Note 1) Auto switches cannot be installed

N.O. 10-SYJ522M Base mounted (With sub-plate) 10-SYJ514M 65(51) 1/8 61(47) 60(46) 82(68) 10-SYJ524M Note) Value for DC.

N.O. 10-SYJ514M Base mounted (with sub-plate) 65 (51) 1/8 60 (46) 61 (47) 82 (68) 10-SYJ524M Note) Value for DC. Add 3 g for AC. ( ): Without sub-plate. 615 3 Port Pilot Solenoid Valve 10-SYJ500 Note) AC-type models that are CE-compliant have DIN terminals only. [Option] How to Order Light/Surge voltage suppressor Rated voltage DC Directional Control Valves Air Grippers Modular F. R.

40 34 22 16 64 58 46 40 34 22 16 64 58 46 40 34 22 16 40 200 100 20 100 0 0 0 0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5 Pressure [MPa] Pressure [MPa] Pressure [MPa] MPa MPa MPa a) Air supply from one side IZT4-16,22,34,40,46,58 Tube: O.D. 6 I.D. 4 b) Air supply from both sides IZT4-64,82,112 Tube: O.D. 6 I.D. 4 Measures pressure Measures Air supply 10mm IZT4-130,160,190

Work load [kg] Size Model LEY25 LEC-MR-RB-032 LEY32 LEC-MR-RB-032 LEY63 LEC-MR-RB-12 Lead 6: LEY25B 20 16 Lead 12: LEY25A 10 8 0 0 200 400 600 800 1000 1200 Speed [mm/s] LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC Lead 5: LEY32C 50 40 46 Area where the regeneration option is required. 37 Area where the regeneration option is

Hs 46 50 56 Approx. Ht 26 26 26 16 Series CLK1 Auto Switch Specifications Lead wire colors inside [ ] are those prior to conformity with IEC standards. Contact Protection Boxes/CD-P11, CD-P12 Auto Switch Internal Circuits Reed switches D-C73 D-C7/C8, D-C73C/C80C, D-B53, D-P75 The above auto switches do not have internal contact protection circuits. 1.

Y-020B Y-032B Y-040B Size 0.2 0.1 9 Type C9 for shaft 46 16 20 25 36 M8 x 1.25 9 18 5 14 CDP-1 0.2 0.1 9 Type C9 for shaft 48 18 20 25 38 9 18 5 14 M10 x 1.25 MQ CDP-1 0.3 0.1 16 3 x 18 l 68 22 24 55 12 38 13 25 49.7 M14 x 1.5 CDP-3 Knuckle pins and retaining rings (cotter pins for 40) are included.

Y-020B Y-032B Y-040B Size 0.2 0.1 9 Type C9 for shaft 46 16 20 25 36 M8 x 1.25 9 18 5 14 CDP-1 0.2 0.1 9 Type C9 for shaft 48 18 20 25 38 9 18 5 14 M10 x 1.25 MQ CDP-1 0.3 0.1 16 3 x 18 l 68 22 24 55 12 38 13 25 49.7 M14 x 1.5 CDP-3 Knuckle pins and retaining rings (cotter pins for 40) are included.

Y-020B Y-032B Y-040B Size 0.2 0.1 9 Type C9 for shaft 46 16 20 25 36 M8 x 1.25 9 18 5 14 CDP-1 0.2 0.1 9 Type C9 for shaft 48 18 20 25 38 9 18 5 14 M10 x 1.25 MQ CDP-1 0.3 0.1 16 3 x 18 l 68 22 24 55 12 38 13 25 49.7 M14 x 1.5 CDP-3 Knuckle pins and retaining rings (cotter pins for 40) are included.

M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2C 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.

LJ1 LG1 LC1 LX LC6D/LC6C Switches 76 46 38 2-M2.5 x 0.45 thread depth 4 5H9 +0.030 0 10 3 depth5 J 27 J x K 25 8 Motor unit Refer to "Applicable Motor List" below for dimensions. (This drawing shows a Tamagawa Seiki, Co., Ltd. motor.)

Base mounted (with sub-plate) 65 (51) 1/8 61 (47) 60 (46) 82 (68) V100 Note) Value for DC. Add 1 g for AC. ( ): Without sub-plate.

For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46.

Applicable bore size Dd9 L1 L2 m d Drill through Included split pin Included flat washer Clevis Knuckle 2 x d Dd9 CDP-2A 40 10 0.040 0.076 46 38 4 3 3 x 18 L Polished round 10 L1 L2 m L1 L2 m CDP-3A 50 40, 50, 63 12 0.050 0.093 55.5 47.5 4 3 3 x 18 L Polished round 12 2 x d Dd9 CDP-4A 63 16 0.050 0.093 71 61 5 4 4 x 25 L Polished round 16 L1 L2 m CDP-5A 80 18 0.050 0.093 76.5 66.5 5 4

68 46 48 11 8 30 32 63.5 71.5 12 3.5 78.4 138.5 134 92 50 45 10 55 52 78 52 54 11 8 30 32 63.5 71.5 12 3.5 78 151 146.5 17 Series CKZ3T Dimensions Without switch XA (mm) Bore size (mm) XA 50 63 100.5 107.5 Metal cover type Leave sufficient space to open and close the metal cover when operating the manual release.