Specification for Option S 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Electric circuit . 12 1 Chapter 13 Specification for Option T 13 1 Safety instructions . 13 1 13 2 Specifications . 13 1 13 3 Remote operation . 13 1 13 4 How to connect the power and signal cable . 13 2 13 5 How to re-start the operation . 13 2 13 6 Electric circuit . 13 3 Chapter 14 Specification
Regarding mounting, refer to Section 3.1.2. 79 No.EX-OMW0011-B 12. Dimensions 12.1. The Modules Manifold Fig. 12-1 Dimensions of the Modules manifold NOTE Fig. 12-1 shows when the EX245-EA2-1 is used. The following table shows the length of the Modules manifold. For the valve manifold side, refer to the instruction manual for the appropriate valve series.
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
MSUB 1=m 12 a 2 1=m 5 2r 2 eThin rectangle board (Parallelogram) iDisc Position of rotation axis: Disc centered about axis of rotation.
Side mounting Body tapped Maximum tightening Thread depth: Max. thread depth: Model Bolt L1(mm) L2(mm) torque MXQ6 M40.7 2.1 5 8 MXQ8 M40.7 2.1 8 11 MXQ12 M50.8 4.4 11 15 MXQ16 M61 7.4 14 19 MXQ20 M61 7.4 9 MXQ25 M81.25 18 12 MXQ6A M40.7 2.1 8 11 MXQ8A M40.7 2.1 8 11 MXQ12A M50.8 4.4 8 12 MXQ16A M61 7.4 12 17 MXQ20A M61 7.4 9 MXQ25A M81.25 18 12 MXQ6B M40.7 2.1 5 8 MXQ8B M50.8 4.4 4 9 MXQ12B
state switch Relay, PLC 12 V Yes Yes No Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) A96 A96V 5 V 24 V Grommet A93 A90 A93V A90V Relay, PLC 100 V 2-wire 12 V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.
Power Supply 12~24vDC (Ripple 10% max.) Consumption Current 45mA max.
CORRENS & CO., LTD. is the general agent in Japan for Hirschmann. 1 2 3 4 5 6 7 8 OUT1 OUT2 Load Load + 12 to 24VDC PNP open collector 80mA Sensor Blue Brown Black NC 1 2 3 4 5 6 7 8 OUT1 OUT2 Load Load + 12 to 24VDC Numbers inside m are terminal numbers. 22 Safety Instructions Series PFA/PFW These safety instructions are intended to prevent a hazardous situation and/or equipment damage
Valve model VCW2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW4 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket) are included
PAX PB Flow Characteristics Water Air 12 (INN.C.) Orifice size (mm ) Port size 12 (INN.C.)
Parianopoulus S.A. 9, Konstantinoupoleos Street, GR-11855 Athens Phone: 01-3426076, Fax: 01-3455578 Norway SMC Pneumatics Norway AS Vollsveien 13 C, Granfoss Nringspark N-1324 Lysaker Tel: (47) 67 12 90 20, Fax: (47) 67 12 90 21 Poland Semac Co., Ltd. PL-05-075 Wesola k/Warszaway, ul. Wspolna 1A Phone: 022-6131847, Fax: 022-613-3028 Czech SMC Czech.s.r.o.
Pmax Vacuum pressure P1 Qmax Q1 Suction flow rate 13-7-3 4 Multistage Ejector Series ZL112 How to Order ZL1 12 K1 12 25 5 M Z E With valve Without valve ZL1 1.2 mm 12 Nozzle diameter Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Lead wire length 0.5 m 2.9 m Nil
A PAF3410S-1S13 PAF3410S-1S19 4 5 10 x 8, 12 x 10, 3/8" x 1/4", 1/2" x 3/8" 12 x 10, 19 x 16, 1/2" x 3/8", 3/4" x 5/8" 115 118 Applicable Fluids Material and Fluid Compatibility Check List for Process Pumps The data below is prepared based on data provided by the material manufacturers.
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900
Port size VCW2 VCW20-12-01 1/8, 1/4 VCW30-12-02 1/4, 3/8 VCW3 VCW30-12-04 1/2 VCW40-12-02 Series 1/4, 3/8 VCW4 VCW30-12-04 1/2 2 3 4 Class 2 Class 3 Class 4 VCW40-12-06 3/4 Bracket material: Stainless steel Valve type Material and insulation type N.C.
NS Power source connector Note 1) 88 68 68 88 12 12 COM D COM C COM B COM A 24VDC COM D COM C COM B COM A 24VDC Branch connector Note 2) Branch connector Note 2) Marker: BN-WH (Made by Phoenix Contact) Marker: BN-WH (Made by Phoenix Contact) 160 136 160 136 93.5 or less 48.8 48.8 46 46 10 10 Note 1) Power supply connector specification (M12, 5 pins, plug) Note 2) Branch connector specification
Series SY 24 DC, 12 DC Coil rated voltage (V) Inrush 0.55 0.8 Power consumption (W) SYJ Holding 0.22 0.3 Specifications other than above are the same as standard models.
14.2 8 R 1/8 12 35.2 10.5 M5 x 0.8 38.6 AS 41.7 18.5 12 R 1/4 17 42.4 10.9 1/8 48.2 15 36.7 46.9 23 12 R 3/8 19 50 14.4 1/8 55.1 19.8 41.9 ASP 64.8 28.6 17 R 1/2 24 61.8 18.3 1/4 69.4 26.5 57.3 25.9 ASN Note 1) Reference dimensions Note 2) Reference dimensions of R thread after installation.