Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
" to 28'(10-85mm) (0.3" to 3.4" std.)5.9" max.)
" to 28'(10-85mm) (0.3" to 3.4" std.)5.9" max.)
EX180 CP1 1658 Integrated Type/For Output Series EX180 SI Unit Specifications EX180-SDN1 EX180-SDN2 EX180-SMJ1 Model DeviceNet CC-Link Applicable system Protocol Communication specification Output specification Environmental resistance Release 2.0 Ver. 1.10 Version Note 1) 156 k/625 kbps 2.5 M/5 M/10 Mbps Communication speed 125 k/250 k/500 kbps Specified file Note 2) EDS file Occupied area
Inch size Metric size 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 Control type 04 06 08 10 12 0 1 Meter-out Meter-in Use 1/8" tube.
Note) AS-FP Metric size Inch size Meter-out Meter-in 0 1 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 AS-FM 04 06 08 10 12 AS-D AS-T With One-touch fitting ASP Thread type M3 Port size Note) For applicable tubing O.D. selection, refer to the Model on page 484. Use 1/8" tube.
) 0.2 MPa Ambient and fluid temperature 5 to 60C (with no freezing) Number of needle rotations 10 rotations Applicable tubing material Nylon, Soft nylon, Polyurethane 15-16-4
TMH M5 Port size ASD M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Applicable tubing O.D. Note) Type 01 02 03 04 Inch size Metric size Elbow Universal 2 3 1/8" AS 23 01 3.2 03 05 07 09 11 13 04 06 08 10 12 4 5/32" 6 3/16" Control AS-FE U10/32 N01 N02 N03 N04 8 1/4" Meter-out Meter-in 0 1 10 5/16" Made to Order Refer to the below for details.
-*04-*DZM 1/2 98 133 47 61 34 52 64 (Max. 73) AVL5000-*06 to 10 3/4 & 1 128 161 59 77 74 64 (Max. 73) AVL5000-*06 to 10-*DZM 3/4 & 1 128 161 59 77 34 74 64 (Max. 73) Soft start valve with lock out H Air direction Nil Left to Right C E D F Port thread Rc Body size R Right to Left Nil 20 1/4 N NPT 30 3/8 F G 40 1/2 50 3/4, 1 Electric entry 1(P) 2(A) Port size Manual lockout Nil 1/4 (AVL2000
Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A RoHS How to Order 002 B HEC A 5 Cooling capacity 002 006 230 W Option 600 W Nil F N None With flow switch A Air-cooled Radiating method NPT thread The option should be specified when ordering. 5 100 to 240 VAC Power supply Communication A B RS-485 RS-232C Select B when communication is not used.
(0.45 MPa) 45 (0.45 MPa) 10 (0.45 MPa) 125 (0.45 MPa) 10 (0.45 MPa) Maximum ow rate [L/min] 120 16 130 16 180 16 Maximum pump head [m] 50 49 55 49 68 49 Settable pressure range5 [MPa] 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55 0.10 to 0.49 0.10 to 0.68 0.10 to 0.49 Minimum operating ow rate6 [L/min] 20 2 25 2 40 2 Tank capacity [L] 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric
Note 3) Assembly of a bracket and set nuts (10-/21-AR20(K)-B to AR40(K)-B) Including 2 mounting screws for the 10-/21-AR50(K)-B, AR60(K)-B Note 4) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of 0.2 MPa or more. When the pressure gauge is attached, a 0.2 MPa pressure gauge will be fitted.
5 !6 !7 Zinc chromated Zinc chromated Zinc chromated Compressed Foam rubber Only RB(C)2015, 2725 10-18-2
0.5 (Proportional valve PID control)0.13/0.18 (at 10 l/min)10/10Approx. 10Rc1/2Stainless steel, PPE, PVC, Copper brazing (Heat exchanger), Bronze, Brass????Stainless steel, PVC, Copper brazing (heat exchanger), Bronze, BrassSingle-phase 200 to 230 VAC 50/60 Hz Allowable voltage fluctuation ?