inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or less to 75
inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or less to 75
inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or less to 75
Series CJ2 is auto switch capable Non-rotating, direct mount, Single acting, spring return/extend, Bore size *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 357, 0.042 lb
Series CJ2 is auto switch capable Double acting, single rod, end lock cylinder, 16mm bore, Mounting types: basic, axial foot, front flange, double clevis, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, 175, 200, Auto switch capable, Air Cylinder with End Lock, ROUND BODY CYLINDER, 353, 0.021 lb
Series CJ2 is auto switch capable Direct mount, single acting air cylinder, Compact and lightweight, Bore sizes *: 10, 16, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, Auto switch capable, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.109 lb
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
NOZZLE TYPE IONIZER, IONIZER, NOZZLE TYPE, 873, 75 lb
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
NOZZLE TYPE IONIZER, IONIZER, NOZZLE TYPE, 873, 75 lb
In addition, the LES series is available in an optional symmetric style *.Reduced tact time - 5,000 mm/s¦ max. acceleration, 400 mm/s max. speed , Positioning repeatability: within ¦0.05 mm , Positioning pattern outputs: 64 points , Compact and space saving , Applicable strokes: 50, 75, 100, 150, Electric Slide Table/High Rigidity Type, ELECTRIC ACTUATOR, 2.5 lb
PF2A712H 75 mm button (SET) Press this button to change to another mode and to set a value. Key-lock function List of outputs button (MODE) Moves on to the function selection mode. Find the diagram of the output required in the table below.
Diaphragm PTFE Material Check valve PTFE, PP, PFA Liquid contact seals FFKM Fluid Refer to P.11 for applicable fluids Discharge rate 1 to 45 L/min 1 to 50 L/min Average discharge pressure 0 to 0.4 MPa Pilot air pressure 0.2 to 0.5 MPa Air consumption Refer to P.14 for air consumption Suction lifting range Note1) Dry Up to 0.5 m (Interior of pump dry) Wet Up to 6 m (liquid inside pump) Noise 75
0,0,0,0 0x00,0x00 Information of 003Bh (Data display 4) 0x0 0,0,0,0 0x00,0x00 Information of 003Ch (Status flag) 0x0031 0,0,3,1 0x00,0x31 Information of 003Dh (Alarm flag 1) 0x0 0,0,0,0 0x00,0x00 Information of 003Eh (Alarm flag 2) 0x0 0,0,0,0 0x00,0x00 Information of 003Fh (Alarm flag 3) 0x0 0,0,0,0 0x00,0x00 Checksum ASCII:LRC RTU:CRC 9,A 0xE7,0xB8 Trailer CR/LF None Total quantity of byte 75
(Alarm flag 2) 0x0 0,0,0,0 0x00,0x00 Information of 003Dh (Alarm flag 3) 0x0 0,0,0,0 0x00,0x00 Information of 003Eh (Alarm flag 4) 0x0 0,0,0,0 0x00,0x00 Information of 003Fh (Alarm flag 5) 0x0 0,0,0,0 0x00,0x00 Checksum ASCII:LRC RTU:CRC 1,3 0x93,0xF1 HRLE Series 3.11 Explanation of function codes 3-11 HRX-OM-Z015 Chapter 3 Serial communication Trailer CR/LF None Total quantity of byte 75
The resistance must be suitable for the characteristic impedance of the cables used for connection and have a combined resistance of 75 ohms or more. 3.9 Identification Code List The following parameters can be changed.