SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2D100-100-E"

The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.42198 lb

The ITV series is IP65 equivalent.Built-in one-touch fitting, Error indication LED, High stability, High-response time, Compact and lightweight, REGULATOR, E/P SPL, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 1A, IT1000 OTHER SPT VERSION, 0.42088 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, 2.20462 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 3.46125 lb

The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, DB, IT4000 1/4 INCNPT VERSION, 1.5785 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.42198 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EA, IT4000 3/8 INCPT VERSION, 1.42198 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, REGULATOR, E/P, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, 10.14126 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EA, IT4000 3/8 INCPT VERSION, 1.42198 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 1.42198 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.76369 lb

The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Operation Manual, REGULATOR, E/P, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, 1.76369 lb

Stepless control of air pressure proportional to an electrical signalMaximum supply pressure: 5.0 MPaSet pressure range: 0.01 to 3.0 MPaMaximum flow rate: 3000 L/min[ANR]Fluid: Air, N2, O2, ArWetted parts: Fluorine grease, Operation Manual, REGULATOR, E/P, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EA, IT2000 3/8 INCPT VERSION, 0.22046 lb

Position Speed Force Target Posn () Counts of input pulses PLC Value converted into pulse tab IO ON E-STOP SET-ON BUSY ALARM SVRE ON ON INP () ActionIO-Enable 23 - 5.3.2.

Recovery and Destruction Law (Japanese law) Refrigerant Regulation (EU) No 517/2014 (Based on the IPCC AR4) R410A 2,088 2,090 Note 1: This product is hermetically sealed and contains fluorinated greenhouse gases (HFC). 7.2 Refrigerant and GWP value IDFC60/70/80/90 Series 7-2 IDX-OM-U010 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size B A E

Description Materials Bonnet Aluminum die-cast Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply / Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, HNBR Body Aluminum die-cast Grease: lithium grease -8- How to order IR 2 0 04 3 2 BG A Option/Semi-standard:Select one each for a to e.

.: ZS-46-E) Item Default setting To obtain the operation manual about this product and control unit, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly.

.: ZS-46-E) Item Default setting To obtain the operation manual about this product, please refer to the SMC website (URL https://www.smcworld.com) or contact SMC directly.

How to Order Manifolds How to Replace One-touch Fittings Caution Caution By replacing One-touch fittings of manifold base, it is possible to change the connection diameter of the 4(A), 2(B), 1(P), 3/5(E) ports. When replacing the One-touch fittings, remove the clip or the plate before pulling the One-touch fittings off.

Used as a 3-Port Valve Manual Override Push-turn locking lever type [E type] Push down on the manual override by finger until it stops, and then turn it 90 clockwise. The manual override is then locked. To release it, turn it counterclockwise. If it is not turned, it can be operated the same way as the nonlocking push type.