SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2D10-30Z-N-M9PSAPC-A"

Note) Port size A B D E300-l03-A 3/8 31.8 30 30 E400-l04-A 1/2 31.8 36 36 Seal A (Spacer width) Note) l in part numbers indicates a pipe thread type. No indication is necessary for Rc; however, indicate N for NPT, and F for G. Separate interfaces are required for modular unit. Part no.

Use a 3-wire auto switch if this specification will not be satisfied. Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. 6.Output operation of the solid state auto switch is not stable for 50 [ms] after powered ON.

AW*-OMF0053-A PRODUCT NAME MICRO MIST SEPARATOR REGULATOR MODEL/ Series AWD20-(F,N)01(F,N)02(B,C,E,G,H)(-1,2,6,C,J,N,R,Z) AWD30-(F,N)02(F,N)03(B,C,D,E,G,H)(-1,2,6,8,J,N,R,W,Z) AWD40-(F,N)02(F,N)04(B,C,D,E,G,H)(1,2,6,8,J,N,R,W,Z) Contents PAGE 1. SAFETY INSTRUCTIONS 15 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 6 5. MAXIMUM APPLICABLE FLOW RATE 7 6.

7 N@4 CL1 A' A A' A MLGC CNG B MNB @5 !5 CNA CNS 20, 25: 50 stroke or less Over 100 stroke CLS CLQ Extension locking (Type F) Retraction locking (Type B) MLGP N#2 u #6 y @2 u #6 #2 y #5 @2 i i RLQ MLU ML1C D-X Section B-B' Section B-B' 20Section A-A' !6 !6 Section A-A' Data Component Parts Description Material Note No. !7 !8 !

7 N@4 CL1 A' A A' A MLGC CNG B MNB @5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -34No.PS-OMW0002-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

3 A A !0 !2 !7 !6 o !5 !1 i !4 Section A-A u Parts list Material Note No. Description No.

[L/min] Flow rate [L/min] Fl ow r at e[ L/ m i n] Fl ow r at e[ L/ m i n] LFE3 0.02 Pressure loss [MPa] 0.015 P r essur e l oss[ M P a] 0.01 0.005 0 0 50 100 150 200 Fl ow r at e[ L/ m i n] Flow rate [L/min] -25No.LV50***-OMQ0004-F IN side straight pipe length (reference value) Straight pipe length 5 Change of accuracy [%F.S.]

Nil Rc G F N NPTF NPT In the case of VVEXB, the 2 in the first digit of the valve station number is a dummy part number.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the and buttons simultaneously for 1 second or longer. -37No.PS-OMU0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Stroke Note 1) 50, 63: L 0 0.008 8-V Effective thread length Y H A B G H B G NN (R) NA Q N F I NA F N CC0.1 NCY3B50, 63 NCY3B6 to 15 (inch) Model Symbol L K J I H G F D A B NN C MM CC N NA P NCY3B6 NCY3B10 NCY3B15 NCY3B20 NCY3B25 NCY3B32 NCY3B40 NCY3B50 NCY3B63 1.38 1.50 2.24 2.60 2.76 3.15 3.62 4.50 5.00 0.19 0.19 0.37 0.31 0.38 0.51 0.56 1.00 1.00 0.16 0.18 0.24 0.24 0.31 0.31 0.39 0.47

A B 1 Actuator section PPS 2 Body PFA A B 3 Diaphragm PTFE 4 End plate PPS 5 Flow rate adjuster section PPS 503 Series LVD Dimensions Basic type A D L K 4 x M (Q) 2 x P One-touch fitting Breathing port PB H C PA G A B N E J B (F) T 2 x U PB PA A B Pilot port threaded type With flow rate adjustment (Max.

6 17 A 18 NO 7 19 NC 8 20 NBR 9 21 NBR 10 22 NBR 11 MHZ2-10 MHZ2-16 MHZ2-20 MHZ2-25 MHZ2-D MHZ2-C MHZ10-PS MHZ16-PS MHZ20-PS MHZ25-PS 20,21,22 MHZ2-S MHZ10S-PS MHZ16S-PS MHZ20S-PS MHZ25S-PS 20,21,22 MHZ2-(N) MHZ-AA1002(N) MHZ-AA1602(N) MHZ-AA2002(N) MHZ-AA2502(N) MHZ2-(N)1 MHZ-AA1002(N)-1 MHZ-AA1602(N)-1 MHZ-AA2002(N)-1 MHZ-AA2502(N)-1 4,5,6,13 Ass'y MHZ2-(N)2 MHZ-AA1002(N)-2

(mm) Connection thread RC Model N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 47 81 17 1 4 7.5 19.5 31.5 21.5 31 13 13.5 17 10 125 6 108 10 55 73 97 91 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 9 22.5 35.5 24 34.5 15.5 14.7 18.5 86 112 Spatter Cover 3: KRMC (Applicable: FR soft nylon) Weight (g) Applicable tubing O.D. (mm) Model N L A N-applicable tubing O.D.

MPa MPa (A) m/N (B) m/N Force N Diaph. (C) m2 Daiph.(A) m2 Force N Block diagram -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.