Applicable load Type 2-wire 3-wire Solid state auto switch Auto switch model D-M9B(V) D-M9N(V) Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 30 mA 50 mA or less Load current range Indicator light Yes Yes 24 VDC relay, PLC PLC: Programmable Logic Controller Refer to page 946 for the applicable auto switch list.
(inch) Thread UNF NPT UNF, M5, M6 10-32 UNF, M5, M6 Weight (g) H (Hex.)
range, Ambient temperature 25 3C) Linearity 1% F.S. or less Repeatability 1% F.S. or less Power supply voltage effect 1% F.S. or less based on the analog output at 18V ranging from 12 to 24VDC Enclosure IP40 Temperature range 0 to 50C; Stored: 10 to 70C (with no condensation and no freezing) Resistance Withstand voltage 1000VAC, 50/60Hz for 1 minute between external terminals and case Insulation
range, Ambient temperature 25 3C) Linearity 1% F.S. or less Repeatability 1% F.S. or less Power supply voltage effect 1% F.S. or less based on the analog output at 18V ranging from 12 to 24VDC Enclosure IP40 Temperature range 0 to 50C; Stored: 10 to 70C (with no condensation and no freezing) Resistance Withstand voltage 1000VAC, 50/60Hz for 1 minute between external terminals and case Insulation
1.9 34 4.5 0.61 11 250 1.0 6 1.05 19 3 8 (10A) 8 1.7 31 340 0.4 10 2.4 43 (15A) 10 2.4 43 1 2 420 Note) Refer to p.4.0-14 the glossary for detail of max. operating pressure differential and max. system pressure.
A 40 44 B 20 22 C 9 10 D 22 24 E 59 66 F 33 34 G 24 25 H 30 40 J 36 46 K 6 9 M 45.5 50.5 N 69 76 VVXA31 VVXA32 17-3-108
Part name (8) (7) (1) Body (2) Element (1) (3) Bowl (4) Auto drain (5) Flange (5) (6) Stopper (7) Element service indicator (8) Bracket (9) Drain port spacer (6) (10) Drain cock (2) (3) (4) (9) (10) Options and spare parts No.
(mm) Mounting screw P L1 H2 D W1 L2 H1 W2 W3 Model (Nominal x Length) 6 4 TM-04 TM-06 TM-08 TM-10 TM-12 6 3.25 72.5 4.5 5.5 6 6.5 6.5 10 5 7.5 7.5 8 12 12 8 10 11 12 12 17 21 23 25 25 2.2 2.8 2.8 3.2 3.2 2 x 6 4.5 91.5 9.5 5.5 77.5 6 12.5 7.5 77.5 6 15 9 93 6.5 2.6 x 8 2.6 x 8 3 x 8 3 x 8 12 10 8 16.3 8.8 14.3 7.5 12 9.8 How to Use Caution 1.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Specifications ID20 ID30 ID40 ID60 Model Compressed air Fluid Operating pressure (MPa) Inlet air temperature (C) Ambient temperature (C) Voltage & power consumption 10% Installation features 0.3 to 1.0 0.3 to 0.9 5 to 50 2 to 50 100 VAC, 200 VAC (50/60
Ensure the piping cools sufficiently before touching. 50% of maximum rated flow [ 50] 50 oC (for all ranges) [ tn_2] Set value (OUT2) Pin number of the connector (On the lead wire) 90o End stop position 0% of maximum rated flow [ 5] 5 oC (for all ranges) [ tH_2] Hysteresis (OUT2) After maintenance is complete, perform appropriate functional inspections and leak tests.
Cylinder component Apply grease to the individual component, shown in the table 10. The following amount is needed per one 100 stroke cylinder. STROKE or 100mm and more Table 10. Grease apply amount 2 125 140 160 Portion to apply 100st 1517 2022 2426 50st Up 3 3 3 For grease, use lithium soap group grease JIS #2 3. Mounting seal 21 - .
rate (l/min (ANR)) 1.5 3 6 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 07, 08, 09, 10, 11 Effective area (mm2) Effective area (mm2) Effective area (mm2) 300 06 1.0 2 4 200 50 100 0.5 1 2 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 14 Flow rate (l/min (ANR)) 20 Flow rate (l/min (ANR)) 10,11 12
Thomas Liquid Peristaltic Pump Flow Rate: 40 ml / min , 40 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Net Weight: 1.54 lbs. / .7 Kg Series Configured Datasheet.
Thomas Liquid Peristaltic Pump Flow Rate: .2 ml / min , .2 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 3.15 in / 80 mm Width: 3.39 in / 86 mm Height: 3.62 in / 92 mm , Length: 3.15 in / 80 mm, Width: 3.39 in / 86 mm, Height: 3.62
Thomas Liquid Peristaltic Pump Flow Rate: 3.5 ml / min , 3.5 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 3.15 in / 80 mm Width: 3.39 in / 86 mm Height: 3.62 in / 92 mm , Length: 3.15 in / 80 mm, Width: 3.39 in / 86 mm, Height: 3.62
Thomas Liquid Peristaltic Pump Flow Rate: 7 ml / min , 7 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 3.15 in / 80 mm Width: 3.39 in / 86 mm Height: 3.62 in / 92 mm , Length: 3.15 in / 80 mm, Width: 3.39 in / 86 mm, Height: 3.62
Thomas Liquid Peristaltic Pump Flow Rate: 6.8 ml / min , 6.8 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 3.15 in / 80 mm Width: 3.39 in / 86 mm Height: 3.62 in / 92 mm , Length: 3.15 in / 80 mm, Width: 3.39 in / 86 mm, Height: 3.62
Thomas Liquid Peristaltic Pump Flow Rate: 110 ml / min , 110 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Net Weight: 3.31 lbs. / 1.5 Kg Series Configured Datasheet.
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
6 SMC Actuators: Copper-free Rotary Actuators Size: 1, 3, 7, 10, 20, 30, 50, 70, 100, 200 Size (Torque) Rotary Actuators Series Application Standard Copper-free 1 3 7 10 20 30 50 70 100 200 Series variations Rotary table Series MSU Basic type MSU With auto switch MDSU Rotary table Series MSQ 20-MSQ Basic type (Adjusting bolt type) 20-MSQA High precision type (Adjusting bolt type) 20-MSQR