(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. Single Flash Safe operational status (Green) ON Operational status 4 OFF No communication error Flash Communication setup error Valve plate (EX600-ZMV ) (Red) Double Flash Communication error (application watchdog timeout) Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Valve plate (EX600-ZMV ) Safety Instructions (5)Connect the SI unit to the valve manifold. Insert the valve plate into the valve plate mounting groove on the side of the SI unit.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 LED Display 300 g Weight Refer to the product catalogue or SMC website (URL https://www.smcworld.com) for more information about product specifications. Valve plate (EX600-ZMV#) The status display LED displays the power supply and communication status. Safety Instructions (5)Connect the SI unit to the valve manifold.

M3 hexagon screw Tightening torque: 0.6 Nm Tie-rod Tightening torque: 0.6 Nm If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.

(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Power supply (0 VDC) 3 6 4 4 3 20 m or less total extension per branch Branch cable length Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

M3 x 18: 2 pcs. (Hexagon socket head cap screw (with spring washer)) CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Solenoid valve or End Plate R (Output Block side) Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Tie-rod: 2 pcs.

M3 x 18: 2 pcs. (Hexagon socket head cap screw (with SW)) : Please refer to the separate catalog regarding assembly and disassembly with other unit. Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Note Hold together so that there is no gap between units and tighten the screws.

Flow indicator LED Safety Instructions Square groove Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. Power indicator LED Indicates the power supply status. LED is ON (Green) when power is ON. LED is ON (Red) when a system error occurred.

They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. 04 Equivalent to M3 (L=6) 20 0.04 to 0.05 Nm 40 Equivalent to M4 (L=10) 0.09 to 0.10 Nm Element Description This unit supplies the fluid from the supply side main piping to the application.

(Recommend using an M3 Phillips head screwdriver with magnet.) Disconnect the piping on top and bottom of the valves and remove the connector for wiring. Replace the valves with new ones. Note) Notes: Mounting orientation of the valves is specified. Make sure that the connector for wiring should be on the upper side of the valve.

(Recommend using an M3 Phillips head screwdriver with magnet.) Disconnect the piping on top and bottom of the valves and remove the connector for wiring. Replace the valves with new ones. Note) Notes: Mounting orientation of the valves is specified. Make sure that the connector for wiring should be on the upper side of the valve.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Viscosity and dynamic viscosity are obtained by the formulas below. Dynamic viscosity [cSt] Viscosity [mPas] Density [g/cm3] 1 [mPas1 [cP] 13 Working Principle 1. When air is supplied, it passes through the switching valve and enters drive chamber B. 2.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Viscosity and dynamic viscosity are obtained by the formulas below. Dynamic viscosity [cSt] Viscosity [mPas] Density [g/cm3] 1 [mPas1 [cP] 14 Working Principle 1. When air is supplied to P1 port, it enters drive chamber A. 2. Diaphragm A moves to the left, and at the same time diaphragm B also moves to the left. 3.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s Pulsation Attenuating Capacity The process pump generates pulsation because it discharges a liquid using two diaphragms.

Table 3-1 Amount of heat radiation and required ventilation Required amount of ventilation [m3/min] Model No.

Step 3 Preparation2 Step 4 Body assembly 3 3 Bolt 1 2 Bolt size, Tool, Tightening torque of bolt (Nm) Valve seal 1 2 1 Bolt size valve Hex Tightening torque wrench size 16 M3 3 0.7 4 4 25 M5 4 1.5 40 M6 5 2.5 Bonnet 50 M8 6 6.1 assembly 63 M10 8 15 80 Body [For XLA-] Pilot port 0.4 MPa [For XLC-] Air should not be applied.

Step 7 Reassembly of bonnet assembly (No.2) 3 Bolt 1 2 4 Bonnet assembly Pilot port Bolt size, Tool, Tightening torque of bolt (Nm) valve Bolt size Hex Tightening size wrench torque XLF-16 M3 3 0.7 -25 M5 4 1.5 -40 M6 5 2.5 -50 M8 6 6.1 -63 M10 8 15 -80 Body Supply air pressure of 0.4MPa (G) to the pilot port.

80 Actuating type Double acting(Dual operation) , pressurize to open/close Fluid Inactive gas under vacuum Operating temperature oC 5 to 60 (High temperature type:5 to 150) Operating pressure Pa (abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pa m3

XMH-16 XMH-25 XYH-25 XMH-40 XYH-40 XMH-50 XYH-50 Flange (valve) size 16,CF034 25 40,CF070 50 Actuating type Manual Fluid Inactive gas under vacuum Operating temperature oC 5 to 150 Operating pressure Pa (abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pa m3

Table 4 Inner cover fixing screw tightening torque[Nm] Model Screw size Tightening torque CYV15 M3 x 0.5 0.3 CYV32 M6 x 1 2.45 Sine suction mechanism is installed as a standard specification. However, cushion effect adjustment is not available. 7. Maintenance (1) Do not disassemble the cylinder tube, linear guide, slide table and other components.