Model: -100 to 100kPa, Piping: NPT 1/8, M5 Female, Output: NPN Open Collector 1 Output+Analog Current Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Bracket B, Operating Manual/Certificate: NON + T, Made to Order: -
Model: -100 to 100kPa, Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Model: -100 to 100kPa, Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: NON + T, Made to Order: -
Model: -100 to 100kPa, Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Model: -100 to 100kPa, Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: None, Operating Manual/Certificate: NON + T, Made to Order: -
Model: -100 to 100kPa, Piping: R 1/8, w/M5 Female, Output: PNP Open Collector 1 Output+Analog Current Output, Display Unit: Fixed SI Unit, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Model: -100 to 100kPa, Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 1 Output, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Model: 0 to -101kPa, Piping: R 1/8, w/M5 Female, Output: PNP Open Collector 2 Outputs, Display Unit: Fixed SI Unit, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: NON + T, Made to Order: M12 4-pin Prewired Connector
Piping: NPT 1/8, M5 Female, Output: NPN Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: NPT 1/8, M5 Female, Output: NPN Open Collector 1 Output+Analog Current Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output+Analog Current Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: R 1/8, w/M5 Female, Output: PNP Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: R 1/8, w/M5 Female, Output: PNP Open Collector 1 Output+Analog Current Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 1 Output+Analog Current Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Initial Value PSI, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: NON + T, Made to Order: -
Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)