Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m): N/
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Cushion: Air cushion, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m): N/
Types: Gasket, Maintenance part name: Seal kit, Bore size(ø): 12, Compatible air cylinder details: Air Slide Table MXY Series, Stroke(mm): -, Surface Treatment: -
With English threads and NPT ports, the NCQ2 series is a versatile cylinder well suited to a variety of applications. The short overall length, of this space saving cylinder helps to make various jigs and equipment more compact. Snap rings are used to secure the head cover, making replacement of seals possible. For maximum flexibility, you can select double-rod end, non-rotating, and single
With English threads and NPT ports, the NCQ2 series is a versatile cylinder well suited to a variety of applications. The short overall length, of this space saving cylinder helps to make various jigs and equipment more compact. Snap rings are used to secure the head cover, making replacement of seals possible. For maximum flexibility, you can select double-rod end, non-rotating, and single
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2 COMPACT CYLINDER, FW, 12MM NCQ2 DOUBLE-ROD, 0.10361 lb
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: D (Built-in), Mounting: UZ (Boss-cut/Rod Trunnion), Bore: 25mm, Port Thread: Rc, Stroke: 125mm, Cushion: A (Air Cushion), Rod End Thread: Rod End Thread
Magnet: D (Built-in), Mounting: B (Basic Style), Bore: 40mm, Port Thread: Rc, Stroke: 300mm, Cushion: A (Air Cushion), Rod End Thread: F (Female Rod End)
Magnet: D (Built-in), Mounting: BZ (Boss-cut/Basic), Bore: 25mm, Port Thread: Rc, Stroke: 125mm, Cushion: A (Air Cushion), Rod End Thread: Rod End Thread
Magnet: D (Built-in Magnet), Mounting: U (Rod Trunnion), Type: N (Rubber Bumper), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 25mm, Rod End Thread: Rod End Male Thread
Bore: 16mm, Stroke: 50mm, Adjuster: ZF (Rubber Stopper, Retraction)
Series: 7 (SY7000), Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 40 (Base Mounted), Pilot Type: Internal Pilot, Coil Specification: Standard, Rated Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Light/Surge Suppressor: Z (With light/surge voltage suppressor)
Magnet: D (Built-in Magnet), Mounting: B (Through-hole), Bore Size: 20mm, Port Thread: TN (Bore 20 to 50; NPT), Stroke: 20mm, Action: D (Double Acting), Rod End: F (Round Bar with Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)