SMC Corporation of America
Elite Part Number Search
Search Results "10-CDA2F63-50"

Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR

Mbit/sec Rated voltage 24 VDC Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11 to 25 VDC 200 mA or less (single GW unit) Current consumption Communication power supply for DeviceNet 50 mA or less Input Unit Manifold Number of inputs

60 24 Weight (kg) 50 Hz Apparent power (VA) Inrush 60 Hz AC 50 Hz Holding 60 Hz Power consumption (W) DC Note 1) Based on JIS B 8375-1981.

[L/min (ANR)] 200 06 200 04 06 08 50 500 04 100 100 0 0 0 0 5 10 5 10 5 10 5 10 Number of needle rotations Number of needle rotations Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the tubing diameter as defined by the product number.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM CG CLEAN-ROOM, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, L5, 32MM CG CLEAN-ROOM, 0.76936 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM CG CLEAN-ROOM, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, L5, 32MM CG CLEAN-ROOM, 1.66381 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CG CLEAN-ROOM, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, M5, 40MM CG CLEAN-ROOM, 2.67022 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 50MM CG CLEAN-ROOM, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, N5, 50MM CG CLEAN-ROOM, 3.59636 lb

Part Number Description: GAUGE   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 115   Family Description: AR REGULATOR   Class Code: 22   Part Code: 2   Reference Code:  B   Click here to report information errorImage shown may not match exact part number

Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.

Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.

15 20 25 30 40 50 60 75 100 125 150 175 200 225 250 275 300 Standard Stroke (mm) Bore Size (mm) 6 8 10 12 16 20 25 MXH MXS MXQ MXF MXW MXP Dual Rods For Twice The Force The MXS, MXQ, and MXW use a twin bore design to double the actuation force while maintaining the single bore height.

Flow Rate and Sonic conductance AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 0.28 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 8 1/4" 5/16" 460 1.3 6 10, 12 8 6 6 10 2 Flow Direction Symbol on Body Tube O.D.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY

CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.

No.CE*-OMP0002-A 3 CEU1 SMC FG 0~50 35~85%RH 3 CEU1CE10.1mm 3 CE1-R** CE1** 3 CEU1** FG 3 DIN 3 2m/s 3 (100ms) 2 2 2 2-1 1 1 1 CEU1 4 2 2 2 2-2 2 2 2 3 3 3 3-1 1 1 1 : : 1 1 (mm) (mm) 25 25 25 25 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 125 150 150 150 150 175 175 175 175 200 200 200 200 250 250 250 250 300 300 300 300 400 400 400 400 500 500 500 500 12 12 12 12

Action Double acting Fluid Air Operating pressure 0.25 to 0.6 MPa Ambient and fluid temperature 10 to 60C (No freezing) Holding force (Workpiece thickness: 0.6 mm) Symbol Holding force Model 1 80 N MHM-A3201-1-X6400 2 50 N MHM-A3201-2-X6400 3 30 N MHM-A3201-3-X6400 MHM-32D1-X6400 80 N MHM-32D2-X6400 50 N MHM-32D3-X6400 30 N Residual holding force 0.3 N or less Lubrication Non-lube Weight

CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.

M5 x 0.8 6 3.5 15.5 50 17.2 ARJ1020F-M5-06 22 12.8 6 VY1 Manifold Base (Option)/Dimensions G PPA 2-3.5 (Mounting hole) 31 (ARJ1020F-M5-04) 32 (ARJ1020F-M5-06) AL Applicable tubing O.D. 4, 6 (Mounting hole) IN (Common) Stations Manifold base part no. 4 6 10 B dimension A dimension 90 130 210 82 122 202 ARJM10-4 ARJM10-6 ARJM10-10 14-4-5 3 Miniature Regulator Series ARJ210 Lightweight body

The Wireless Remote is 10 already registered. 3. When another Wireless Base is in pairing 3. Another Wireless Base is mode, the Wireless Remote will be displayed for the Base. Keep one Wireless Base in pairing mode. in pairing mode. -122No.EX-OMV0017-C 10. Release Notes Revision No.