SMC Corporation of America
Elite Part Number Search
Search Results "ISE20CH-R-P-N02L-WY"

K C37 1 25 L Stainless steel G 24 VDC DIN terminal With surge voltage suppressor Note) H 100 VAC J 110 VAC K 200 VAC L 230 VAC N 100 VAC Conduit terminal With surge voltage suppressor P 110 VAC Q 200 VAC R 230 VAC T 100 VAC Conduit With surge voltage suppressor U 110 VAC V 200 VAC W 230 VAC Z Other voltages Note) For the class H type DIN terminal, use it in combination with the connector

Pilot valve symbol 1 2 3 4 5 6 100 AC 200 AC 110 AC 220 AC 24 DC 12 DC q w e r t y u i Nil Y Nil Y Nil Nil Nil Nil K1 K1 J1 J1 Q1 Q2 N1 N2 Combinations (1) to (8) in the above table are the only possible options. 850

VALVE, SOFT START, http://smcpneumatics.com/SS5V2-10FD.pdf, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption

2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV30003/81.5 MPa0.2 to 1 MPa1/80 to 60C (1)37490.48100, 200, 110 to 120, 220 VAC (50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?

2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV40001/21.5 MPa0.2 to 1 MPa1/80 to 60C (1)61760.74100, 200, 110 to 120, 220 VAC (50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BASE MOUNTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, 2A, VQZ100 NO

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BASE MOUNTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, 2A, VQZ100 NO

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MFLD, BAS MOUNT, VQZ200, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, 2J, VV3QZ* NO SIZE RATING, 1.14400 lb

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MFLD, BODY PORTED, VQZ300, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, 2J, VV3QZ* NO SIZE RATING, 1.23200 lb

VALVE, SOFT START UP, http://smcpneumatics.com/SS5V2-10FD.pdf, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption

NVZ1000 standard manifold, North American, Manifold style: single base/B mount, Valve stations: 2 - 20, Common SUP and EXH, P/R port: 1/8 NPTF, A/B port: M5 X 0.8, MANIFOLD, 12-STA *LQA, VALVE, VV4Z/VV5Z MANIFOLD VZ 4/5 PORT, NJ, VV4/5Z* BASE MT 1/8, .31900 lb

(convertible) , Threads: Rc, NPT, NPTF, G, VALVE, AIR PILOT, VALVE, VP3/5/7 SOL VALVE 3-PORT, HA, VP3/5/7 BODY PT 3/8, .77161 lb, ModelPort size1 2 (P A)2 3 (A R)Weight (g) Note) C [dm3/(s?bar)]bCvC [dm3/(s?bar)]bCvVPA5441/47.50.161.77.30.201.7358 (233)

(convertible) , Threads: Rc, NPT, NPTF, G, VALVE, AIR PILOT, VALVE, VP3/5/7 SOL VALVE 3-PORT, JA, VP3/5/7 BODY PT 1/2, 1.13535 lb, ModelPort size1 2 (P A)2 3 (A R)Weight (g) Note) C [dm3/(s?bar)]bCvC [dm3/(s?bar)]bCvVPA7423/811.90.212.711.80.202.7501

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MFLD, BODY PORTED, VQZ100 *LQA, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, 2J, VV3QZ* NO SIZE RATING, .22000 lb

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MFLD, BODY PORTED, VQZ200, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, 2J, VV3QZ* NO SIZE RATING, .81400 lb

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MFLD, BASE MOUNT, VQZ200, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, 1J, VV3QZ* 0THER SIZE RATING, 1.37500 lb

(convertible) , Threads: Rc, NPT, NPTF, G, VALVE, AIR PILOT, VALVE, VP3/5/7 SOL VALVE 3-PORT, JA, VP3/5/7 BODY PT 1/2, 1.48812 lb, ModelPort size1 2 (P A)2 3 (A R)Weight (g) Note) C [dm3/(s?bar)]bCvC [dm3/(s?bar)]bCvVPA7443/812.90.102.913.30.243.1693 (476)

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, UA, VQZ100 BUILT

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MFLD, BODY PORTED, VQZ100, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, 2J, VV3QZ* NO SIZE RATING, .68200 lb

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BODY PORTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb