SMC Corporation of America
Elite Part Number Search
Search Results "HRW008-H2-Y"

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, BRANCH Y, ONE-TOUCH FITTING, 957, 42.6 lb

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

NVFR2000 series manifold, North American, Plug-in and non plug-in styles, Wiring types (non plug-in): grommet, grommet terminal, Conduit terminal, DIN connector, L plug connector M plug connector, Wiring types (plug-in): terminal block, multi-connector, D-sub connector, Maximum stations: 17 (depending on style), MANIFOLD ASS Y, 5-STA., VALVE, VV*FR* BASE MT 1/8, 1.81720 lb

This product is obsolete. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, NC, 50MM CQ2 OTHERS (COMBO), 3.96832 lb

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

Part Number Description: JOINT (CQ2)   Product Line: A   Product Line Description: ACTUATOR   Family Code: 515   Family Description: CQ2 COMPACT CYLINDER   Class Code: 21   Part Code: 2   Reference Code:  J   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

ACCESSORY KIT, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, 21, VBA NO SIZE RATING PARTS, 0.33069 lb

ACCESSORY KIT, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, 21, VBA NO SIZE RATING PARTS, 1.02358 lb

ACCESSORY KIT, AIRLINE EQUIPMENT, VBA BOOSTER REGULATOR, 21, VBA NO SIZE RATING PARTS, 0.33069 lb

The specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted. Boosts local line pressure without requiring additional power

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

The ARP is a modular style, direct operated precision regulator.  A locking adjustment knob allows the pressure to be set, and then locked to prevent accidental setting changes. The ARP20/30/40 series is available with a back flow function that exhausts the air pressure in the outlet side reliably and quickly.  Special applications include (10-) clean room compliant, (20-)copper-free, fluorine-free

The CRA1 rack andamp; pinion rotary actuator offers very high torque-to-size and accurate positioning. Bore sizes are 30, 50, 63, 80 and 100mm. Units may be ordered auto-switch capable and with cushions. Dimensions range from 3" X 4" X 2" to a maximum of 8" X 9.65" X 4.41". Single shaft end or double shaft end models are available.Standard type rotary actuator, 3 mounting types available