Bore size 15 32 15 mm 32 mm Standard stroke (mm) 100, 150, 200, 250 300, 350, 400, 450 500, 600, 700 Bore size (mm) MG 15, 32 CX DSpecifications -X 15 32 Bore size (mm) 20Atmosphere to 1.3 x 10-4 Pa (ABS) Operating environment pressure Air/Inert gas Operating atmosphere Data Air/Inert gas Fluid Double acting Action 0.5 MPa Proof pressure 0.05 to 0.3 MPa Operating pressure range 1.3 x 10-7
For M12 For 7/8 inch 1 The pin layout for 4 and 5 pin connector is different. Refer to the dimensions on page 14.
Power Block EX9-PE1-X15/X22/X23/X24 EX260 Series EX600 Series Specications Model EX9-PE1-X15 EX9-PE1-X22 EX9-PE1-X23 EX9-PE1-X24 Rated voltage 24 VDC +10%/5% Internal current consumption External power supply 1: 20 mA or less, External power supply 2: 20 mA or less Power supply Outputs 0 to 3: External power supply 1 (PWR1) Outputs 4 to 7: External power supply 2 (PWR2) Outputs 8 to 11: External
Note 6) Window comparator mode Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more. (In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.) Note 7) The flow switch conforms to the CE mark. 1
Port size Rated ow range 501 102 202 04 1/2 V V 06 3/4 V Note 7) Each option is not assembled with the product, but shipped together.
Model HRS200-Am-46-mS Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.65 Control method PID control Ambient temperature/Altitude1, 7 C Temperature: 5 to 45, Altitude: less than 3000 m Circulating uid1, 2 Tap water, 15% Ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity3, 7 kW 20.5 Heating capacity4 kW
So, apply the sealing tape or sealant to the screw thread before use. 4 For handling of the pressure gauge and the detailed specifications, refer to Pressure Gauges in Best Pneumatics No. 7. 812
Electrical entry/Lead wire length Nominal size (Torque) 1 3 7 20 MSUA 1 MSUA 3 MSUA 7 MSUA20 Grommet/Lead wire: 0.5 m Grommet/Lead wire: 3 m Connector/Lead wire: 0.5 m Connector/Lead wire: 3 m Connector/Without lead wire Nil L C CL CN Rotating angle Symbol Applicable Rotating angle Single vane 90 180 90 180 Available only with R73, R80 and T79 type connectors.
Note 3) 10 to 15 in decimal number are displayed as follows in the 7-segment LED. Decimal display Hexadecimal display 10 A 11 b 12 c 13 d 14 E 15 F Note 4) Applicable to non-magnetizing lock 47
1 4 1 2 D DIN terminal 1 2 G Grommet (Lead wire length 300 mm) Grommet (Lead wire length 600 mm) DIN terminal DIN terminal (Without connector) Nil Without sub-plate H D DO 2 01 1 8 1 8 Base mounted 02 1 4 1 4 Caution Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
Without sub-plate 00 VPA4 54, 4 74 JIS Symbol (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 (32A) 1 4 1 (40A) 1 2 1 03 2 position double 2 position single Body size VPA4150/4170 VPA4250/4270 04 06 10 0 1 VPA4 5 Piping standard 3 4 standard 11 4 Side ported Bottom ported W/o sub-plate 5 7 0 1 12 14 0 1 VPA4 7 4 Option Side piping only 3 position exhaust center 3 position closed center VPA4350 VPA4450
1/8 Port size 7-1/8 2-4.5 mounting hole 5-7-2
Symbol Specications X01 Different diameters (IN side < OUT side) X02 Different diameters (IN side > OUT side) X03 Blue element X04 Filtration: 10 m X05 FKM/Oil free (Seal) X06 Nylon 5 20 L/min 750 mm2 7 100 L/min 1260 mm2 Applicable tubing O.D. Metric size Symbol Applicable tubing O.D.
Bore sizes range from 7/16in. to 2in. and standard strokes from 1/2in. to 12in.. Double acting single rod , Bore sizes *: 7/16, 9/16, 3/4, 7/8, 1 1/16,1 1/4, 1 1/2, 2 , Mounts: nose, rear, end, rod, block , Variety of switches and lead wire lengths, Optional Rod Boot ROUND BODY CYLINDER. APC Default Name. NULL lb. E30.
Bore sizes range from 7/16in. to 2in. and standard strokes from 1/2in. to 12in.. Double acting single rod , Bore sizes *: 7/16, 9/16, 3/4, 7/8, 1 1/16,1 1/4, 1 1/2, 2 , Mounts: nose, rear, end, rod, block , Variety of switches and lead wire lengths, Optional Rod Boot, BOOT, ACTUATOR, NCM ROUND BODY CYLINDER, L1, 1.25 INCH NCM PART, .05500 lb
Bore sizes range from 7/16in. to 2in. and standard strokes from 1/2in. to 12in..
Bore sizes range from 7/16in. to 2in. and standard strokes from 1/2in. to 12in.. Double acting single rod , Bore sizes *: 7/16, 9/16, 3/4, 7/8, 1 1/16,1 1/4, 1 1/2, 2 , Mounts: nose, rear, end, rod, block , Variety of switches and lead wire lengths, Optional Rod Boot, AUTO SWITCH MNT KIT, ACTUATOR, NCM ROUND BODY CYLINDER, N2, 2.0 INCH NCM ACCESSORY, .00000 lb
Bore sizes range from 7/16in. to 2in. and standard strokes from 1/2in. to 12in.. Double acting single rod , Bore sizes *: 7/16, 9/16, 3/4, 7/8, 1 1/16,1 1/4, 1 1/2, 2 , Mounts: nose, rear, end, rod, block , Variety of switches and lead wire lengths, Optional Rod Boot, BRACKET, PIVOT, NCM150, ACTUATOR, NCM ROUND BODY CYLINDER, M2, 1.5 INCH NCM ACCESSORY, .01540 lb
normally open styles.3 port, pilot poppet type valve , Available with power saving circuit to reduce power consumption , Port sizes from 1/8 to 1/2, depending on series , Thread types: Rc, G, NPT, NPTF, VP3/5/7 BODY PT 1/2, VALVE, VP3/5/7 SOL VALVE 3-PORT, JA, VP3/5/7 BODY PT 1/2, 1.11153 lb, ModelPressure specificationsResponse time ms (at 0.5 MPa) Without light/surge voltage suppressorWith
Bore sizes range from 7/16in. to 2in. and standard strokes from 1/2in. to 12in.. Double acting single rod , Bore sizes *: 7/16, 9/16, 3/4, 7/8, 1 1/16,1 1/4, 1 1/2, 2 , Mounts: nose, rear, end, rod, block , Variety of switches and lead wire lengths, Optional Rod Boot, 1 1/16 NCQ8 DOUBLE-ACTING, ACTUATOR, 1 1/16 NCQ8 DOUBLE-ACTING