To connect a drain discharge pipe, use a pipe with a minimum bore of 10, and a maximum length of 5 m. Avoid using a riser pipe.

The VH series valve’s piping ports are as follows: 1 (P) = supply port, 2 (A) = A port, 3 (R) = exhaust port, and 4 (B) = B port. A silencer can be installed on the 3 (R) exhaust port.
Note 1) Do not apply pressure from any port other than the 1 (P) port. If supplied from another port, air will leak.

Please exercise caution when using this item in a clean room. There is a possibility of plasticizer and other materials precipitating on the tube surface and detracting from the cleanliness level of the room.

and Japanese NPT1/4 (M5 female threaded) N02 Option 1 G1/4 (M5 female threaded) Rc1/8 URJ1/4 TSJ1/4 Note) Fixed unit ISE80H: MPa Others : MPa, kPa With unit display switching function Fixed SI unit Note) F02 Nil C01 A2 B2 M P Initial value psi Option 2 Bottom ported R1/4 (M5 female threaded) None Nil 02L With bracket NPT1/4 (M5 female threaded) N02L A C01L A2L B2L Rc1/8 ZS-24-A ZS-35-A URJ1

Vertical Suction Filter FHIA Series How to Order FH I A N 04 M M R 074 Vertical suction filter Relief valve Hydraulic fluid R D N W V With relief valve None (Blanking plate) Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication Differential pressure indicator Differential pressure indication switch Note) Port size M E D 04 06 08 10 12 16 20 24 28 32 1/2B None

N m (A) / N ( B) /N () m 2 ( A) m 2 N -5- 1 SUP OUT 2 %F.S. 3 , 4 R B(P36201023) G 2 3 Rc,F N IR1000G33-2-01 G33-P2-N01-X30 IR1010G33-4-01 G33-P4-N01-X30 IR1020G33-10-01 G33-P10-N01-X30 011/84 Rc NNPT FG 00.0050.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R101BG M AX.

square embedded type pressure gauge or with a digital pressure switch. *2 5 to 50C for the products with the digital pressure switch 68

For VH200 series valves, you can select from all side piping or side piping to the P, A, and B ports with bottom piping to the R port. For VH600 series valves, only side piping to the P, A, and B ports with bottom piping to the R port can be selected.

Refer to page 17-3-65 for ordering a coil only.

R CAC408 40 40A Flange P 110 VAC F N.O. Q 200 VAC 9 50A N.C. S CAC408 50 50A Flange R 230 VAC G N.O.

2-Color Display (200 L type only) Digital Flow Switch Series PFMB7 RoHS How to Order PFMB7 201 C8 A M Type Calibration certificate Note 1) Integrated display 7 None With calibration certificate Nil A Rated flow range (Flow rate range) Note 1) Certificate in both English and Japanese Made to Order 2 to 200 L/min 201 Flow adjustment valve Unit specifications Nil S None Yes Unit selection function

Other M5 size hole at the left side of the adapter plate is a breathing port for spool valve. Do not plug or tighten it. Rc 1 1 2, 3 4, Rc 1 1 2, 3 4, (P port) (A port) Rc 1 1 2, 3 4, (R port) 1808

The continuous duty AC type is equipped with a rectifier, so a diode will be provided. Construction Symbol (A)2 (R)3 1(P) Component Parts Material Aluminum die-casted No. Note Platinum silver Black Black 1 Description Cover Body 2 3 Resin Resin End cover Spool valve assembly 5 Stainless steel Return spring 4 Aluminum, NBR Black 6 Resin Molded coil 1410 A

How to Order VP 3 4 2 5 G 1 01 A Body ported Series 3 5 7 Pilot type VP300 VP500 VP700 Thread type Bracket Nil R Internal pilot External pilot Nil F N T Rc G NPT NPTF Nil F Without bracket With bracket Pressure specification Nil K Standard (0.7 MPa) High-pressure type (1.0 MPa) Coil specification Nil T Standard Rated voltage With power saving circuit (DC only) Type of actuation A B N.C.

) ( ): Fluid: CO2 Calibration certificate Flow adjustment valve None With calibration certificate Nil A Nil S None Yes The certificate is written in English and Japanese. Other languages are available as specials.

Note) Each port size will be a big size for standard. When the small size is desired, indicate separately.

This tank has a capped opening separate from the fill port for easier cleaning when necessary.  Finally, the ambient temperature upper limit has been increased to 45°C.  The HRS-R shares many features with the standard HRS, including common overall dimensions, caster wheels for mobility, an angled fill port with a level indicator for the fluid tank, and a heating function. 

This tank has a capped opening separate from the fill port for easier cleaning when necessary.  Finally, the ambient temperature upper limit has been increased to 45°C.  The HRS-R shares many features with the standard HRS, including common overall dimensions, caster wheels for mobility, an angled fill port with a level indicator for the fluid tank, and a heating function. 

Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.

Cylinder Port: NPT, Arm Opening Angle: 105°, Arm Position: D (Both Sides), Switch Type: T (Turk PNP), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A031 (25mm Offset Machined ref NAAMS ACA133M), L Arm Mtg Position: A (Mounting Position A), L Arm Style: A031 (25mm Offset Machined ref NAAMS ACA133M)